Electrical Components: Capacitors, Breakers, Contactors, Relays, Fuses & More

Voomi Supply carries electrical components for HVAC repairs, equipment service, and building electrical work, including batteries, capacitors, circuit breakers, contactors, disconnects, fuses, relays and switches, sequencers, terminals and wire connections, transformers, timers, and wires and cables. Browse by part type or by brand, including Siemens, Eaton, IDEC, and Leviton. Electrical parts are matched by voltage, amperage, and model, so check the ratings on each listing.

Why buy from Voomidatasheet
CategoriesCapacitors, breakers, contactors, relays & more
PartsFuses, transformers, timers, sequencers & cable
RatingsVoltage, amps and poles on listings
BrandsSiemens, Eaton & more
ShippingSame-day on select items ordered by 12 pm
Find your electrical part or model number
Same-DayDispatch on select items ordered by 12 pm
12 CategoriesBatteries to wires & cables
Name BrandsSiemens, Eaton, ABB, Leviton, Milbank and more
Spec DetailsVoltage, amperage and fit on listings
US SupportPhone, chat and email help

Popular electrical components

Shop all electrical components →

Brands we carry

Which electrical component do I need?

Most orders start with a symptom or a job: a unit that will not start, a tripped or failed breaker, a missing disconnect, or a control circuit that needs power. Match the job to the component type, then check ratings and fit on the listing.

What you need to doComponentShop
Start or run a motor or compressorCapacitorCapacitors
Switch a compressor or other heavy loadContactorContactors
Switch a low-power control circuitRelay or switchRelays & switches
Protect a circuit or feed a panelCircuit breaker or lugCircuit breakers
Isolate equipment for serviceDisconnectDisconnects
Replace a blown fuseFuseFuses
Stage electric heat stripsSequencerSequencers
Power a 24V control circuitTransformerTransformers
Delay, schedule, or cycle a loadTimer or timer switchTimers
Connect or terminate wiresTerminal, lug, or connectorTerminals & wire connections
Run power or control wiringWire or cableWires & cables
Power a tool, sensor, or remoteBatteryBatteries

Capacitors: match the type, microfarads, and voltage

Start capacitors give a motor its initial boost and are active only during startup, run capacitors supply continuous power while the motor operates, and dual capacitors combine both functions in one unit. Our guide to AC capacitors covers symptoms, testing, and replacement.

CapacitorKey specs from the listingNotes
Lennox 89M97Dual run, 55/10 MFD, 440V, roundListed for Lennox 13ACD and LCS13DC series
Hoshizaki 3A0076-11Start capacitor, 145-174 uF, 220 VACFit not listed; confirm against the unit label

Match the microfarad value and type exactly, and never use a lower voltage rating than the original. A reading more than 10 percent below the rated microfarads is a common reason to replace a capacitor. Capacitors can hold a charge after power is cut, so discharge them safely first. Browse capacitors.

Breakers, lugs, and panel parts

PartKey specs from the listingNotes
Siemens MBKQR3200HABreaker mounting kit, 240 VAC, 3-phase, 65 kA, includes HQR23B200 breakerFor Siemens P1 panelboards; confirm panel revision
Square D HOML22252-pole, 225 A sub-feed lug, wire range AWG 1 to 300 kcmil, copper or aluminumDistributes power without overcurrent protection; for Homeline load centers; confirm mounting
Leviton LFTLAFeed-through lug, 3 AWG to 300 kcmil, copper or aluminum, plug-onLoad center accessory
ICM Controls ICM493Line voltage monitor, 230 VAC, 40 A, surge protection, NEMA 3RFor mini-splits and similar outdoor units

Breakers are matched by amperage, poles, interrupting rating, and panel type. Sub-feed lugs and kits are not breakers, so check what each listing actually provides. Browse circuit breakers and terminals and wire connections.

Contactors, relays, and sequencers

Relays handle low-power control signals, while contactors carry heavier loads. Our guide to the difference between a relay and a contactor gives about 10 amps as the usual relay limit and 9 amps and above for contactors.

PartKey specs from the listingUse
Carrier HN52PD0242-pole, 24V, 40AHeavy loads such as compressors
IDEC RH4B-UAC24V4PDT, 24VAC coil, plug-inControl circuits; contact rating not listed
White-Rodgers 24A34-224V control, on 30 to 90 s, off 1 to 30 s, 25 A resistive, 3000 W, multi-poiseStaging electric heat strips

Check that the control voltage matches the coil rating, and match the contacts to the load. Browse contactors, relays and switches, and sequencers.

Disconnects and meter sockets

For air conditioning equipment, the National Electrical Code calls for the disconnecting means to be within sight of and readily accessible from the equipment, where within sight means visible and not more than 50 feet away. Outdoor enclosures should be weatherproof, such as NEMA 3R. Our guide to choosing an AC disconnect box covers fusible and non-fusible types.

ItemKey specs from the listingNotes
Mars 8332160A, 240V, NEMA 3R, steel enclosure, non-fused, three-phasePole count not listed
Milbank U6281-XL-200-5T9200 A, 1 phase, up to 240 VAC, 5 jaws, Type 3R, lever bypass, overhead or undergroundMeter socket with main and load center
Milbank U4413-O-KK-BLG200 A, 600 V AC, 4 terminals, ringless, surface mountMeter socket
Milbank U1797-O-K3L-K2L320 A, 1 phase, 600 V AC, 4 jaws, lever bypass, underground, Type 3RMeter socket

Utilities set their own meter socket requirements, so confirm them before you order. Have a licensed electrician install disconnects and meter sockets. Browse disconnects.

Fuses, transformers, and timers

PartKey specs from the listingNotes
Mars 824095 A, 250 V, fast acting, 1/4 x 1-1/4 inchSmall cartridge fuse
Allied 69M58200 A, 250 VFuse class not listed
Carrier HT01CN24140 VA, 208 and 230 V primary, 24 V secondaryAbout 1.7 A at 24 V
Mars 32391240 VAC, 50/60 Hz, 0.1 to 8 minute adjustable delayTime delay
Intermatic T1471BR24-hour mechanical time switch, 4PST, 40 A per pole, 120 V, NEMA 3RDaily schedule switching

A fuse is a one-time device that must be replaced after it opens, while a breaker can be reset. Match the current, voltage, type, and size on the fuse, and size a transformer by dividing VA by volts. Browse fuses, transformers, and timers.

Wires and cables

Wire size depends on the circuit. For copper conductors, the National Electrical Code limits overcurrent protection on small conductors to 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG, and other rules for ambient temperature and conductor count can apply.

CableKey specs from the listingUse
Lionbeam LB-W1645SSW16 AWG, 4 stranded copper conductors, overall shield, CMR, white PVC jacket, 500 ft pull boxShielded control and signal wiring
Rectorseal DUCKTSTRIPUNV2505 conductors: two 16 AWG stranded signal, one 14 AWG solid ground, two 14 AWG stranded power, 250 ftPower and control between mini-split outdoor and indoor units

Check the jacket rating, conductor count, and gauge against the equipment instructions. Browse wires and cables.

Batteries

BatteryKey specs from the listingNotes
Rayovac ALD-12D alkaline, 1.5V, 12 pack, 7500 mAhGeneral use
Energizer EN229V industrial alkaline, 600 mAh, 5 year shelf lifePack count not listed
Duracell DL2032B4PK3V lithium coin cell, size 2032Sold as a 4-pack per the title
Inficon 703-057-G1NiCd battery, 3-packFor D-TEK refrigerant leak detectors

Match the size, voltage, and chemistry to the device. Our guide to rechargeable batteries for HVAC tools and devices covers compatibility and care. Browse batteries.

Before you order: things to check

  • Read the ratings on the original part: voltage, amperage, microfarads, poles, and coil voltage
  • Confirm the fit or model, since some listings name only certain equipment
  • Check the title, the specifications, and the description together, since model details can differ between them
  • Match the fuse class and type, not only the amp and voltage rating
  • Use a weatherproof enclosure such as NEMA 3R for outdoor disconnects and meter sockets
  • Confirm utility requirements before ordering a meter socket
  • Turn off and verify power before working, and discharge capacitors safely
  • Hire a licensed electrician for panel, disconnect, and service entrance work
  • Read the overview in our guide to top HVAC electrical components

Electrical components glossary

MFD
Microfarad, the unit that rates capacitance; MFD and uF mean the same thing on a capacitor label. Shop capacitors →
Dual run capacitor
A capacitor that serves two motors, such as a compressor and a fan, and is labeled with two values like 55/10 MFD. Shop capacitors →
Contactor
An electrically controlled switch that carries high current to loads such as compressors and motors. Shop contactors →
Non-fused disconnect
A switch that cuts power to equipment without containing fuses, relying on an overcurrent device elsewhere. Shop disconnects →
Sequencer
A time-delay switch that turns electric heat strips on in stages to reduce the electrical load. Shop sequencers →
VA
Volt-amps, the rating that shows how much load a transformer can carry; VA divided by volts gives amps. Shop transformers →
Meter socket
The enclosure that holds the utility meter, rated in amps and voltage, with jaws that grip the meter blades. Shop disconnects →

Frequently asked questions

What electrical components does Voomi Supply carry?

The range covers twelve areas: batteries, capacitors, circuit breakers, contactors, disconnects, fuses, relays and switches, sequencers, terminals and wire connections, transformers, timers, and wires and cables. Brand collections add parts from Siemens, Eaton, ABB, IDEC, Leviton, Milbank, and others. Browse the full electrical components collection or search by part number.

How do I choose a replacement capacitor?

Read the label on the old capacitor for the capacitance in microfarads, the voltage rating, and the type: start, run, or dual. For example, the Lennox 89M97 is a round dual run capacitor rated 55/10 MFD at 440 volts, while the Hoshizaki 3A0076-11 is a start capacitor listed at 145-174 uF and 220 VAC. Match the microfarad value and type exactly. A higher voltage rating is commonly accepted as a replacement, but a lower one is not.

When should I replace an AC capacitor?

Common signs include a unit that hums but does not start, a bulging or leaking case, and a meter reading that is off the rating. Our capacitor guide recommends replacement if the measured value is more than 10 percent below the rated microfarads. Capacitors can hold a charge after power is cut, so discharge one safely before testing, and leave the work to a trained technician if you are unsure.

What is the difference between a relay and a contactor?

A relay switches low-power control circuits, and our technician guide describes relays as handling currents up to about 10 amps. A contactor switches heavy loads such as compressors and motors, typically at 9 amps and above, and often has three power contacts for three-phase loads. For example, the Carrier HN52PD024 is a 2-pole, 24V, 40A contactor, while the IDEC RH4B-UAC24V is a 4PDT relay with a 24VAC coil. Always match the control voltage to the coil rating.

What is the difference between a fusible and a non-fused disconnect, and where does it go?

A fusible disconnect holds fuses that open the circuit on an overcurrent, while a non-fused disconnect is a switch that relies on an overcurrent device elsewhere, such as a breaker. For air conditioning equipment, the National Electrical Code calls for the disconnecting means to be within sight of and readily accessible from the equipment, and within sight means visible from and not more than 50 feet away. Outdoor installations need a weatherproof enclosure such as NEMA 3R, like the Mars 83321 listing. Browse disconnects by amp rating and enclosure.

Do I still need a disconnect if my unit has a circuit breaker?

Yes. The breaker provides overcurrent protection, but a separate disconnect within sight of the unit lets a technician isolate it safely during service. Always verify power is off before working, even if you believe it is disconnected, and have a licensed electrician handle installation to meet code.

How do I choose the right fuse?

Match the current rating to the circuit, and use a voltage rating equal to or higher than the circuit voltage. Then check the type, such as fast acting or time delay, and the physical size. For example, the Mars 82409 is a 5 amp, 250 volt fast acting fuse that measures 1/4 inch by 1-1/4 inches, and the Allied 69M58 is rated 200 amps at 250 volts but does not list its fuse class, so confirm the class against your equipment.

What wire size do I need for a circuit?

For copper conductors, the National Electrical Code limits overcurrent protection on small conductors to 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG. Aluminum conductors have lower limits, and other rules for ambient temperature and conductor count can apply. Check the wire markings and local code, and browse wires and cables for the type and rating you need.

How do I size a 24V control transformer?

Match the primary voltage to your supply, then choose a VA rating that meets or exceeds the total load on the 24 volt side. Dividing VA by volts gives the maximum current, so the Carrier HT01CN241 at 40 VA and 24 volts can supply about 1.7 amps. It lists 208 and 230 volt primaries. Add up the control loads such as relays, contactors, and the thermostat before you choose.

What does an electric heat sequencer do?

A sequencer staggers the activation of electric heat strips instead of turning them all on at once, which reduces the electrical load and protects components. The White-Rodgers 24A34-2 is a 24 volt sequencer with an on timing of 30 to 90 seconds and an off timing of 1 to 30 seconds, rated 25 amps resistive. Match the control voltage, the time delay, and the contact rating to the original. See sequencers for more.

Read more

Visit the blog →

Keep shopping