Electrical Components: Capacitors, Breakers, Contactors, Relays, Fuses & More
Voomi Supply carries electrical components for HVAC repairs, equipment service, and building electrical work, including batteries, capacitors, circuit breakers, contactors, disconnects, fuses, relays and switches, sequencers, terminals and wire connections, transformers, timers, and wires and cables. Browse by part type or by brand, including Siemens, Eaton, IDEC, and Leviton. Electrical parts are matched by voltage, amperage, and model, so check the ratings on each listing.
Shop by category
View all electrical components →Popular electrical components
Shop all electrical components →Brands we carry
Which electrical component do I need?
Most orders start with a symptom or a job: a unit that will not start, a tripped or failed breaker, a missing disconnect, or a control circuit that needs power. Match the job to the component type, then check ratings and fit on the listing.
| What you need to do | Component | Shop |
|---|---|---|
| Start or run a motor or compressor | Capacitor | Capacitors |
| Switch a compressor or other heavy load | Contactor | Contactors |
| Switch a low-power control circuit | Relay or switch | Relays & switches |
| Protect a circuit or feed a panel | Circuit breaker or lug | Circuit breakers |
| Isolate equipment for service | Disconnect | Disconnects |
| Replace a blown fuse | Fuse | Fuses |
| Stage electric heat strips | Sequencer | Sequencers |
| Power a 24V control circuit | Transformer | Transformers |
| Delay, schedule, or cycle a load | Timer or timer switch | Timers |
| Connect or terminate wires | Terminal, lug, or connector | Terminals & wire connections |
| Run power or control wiring | Wire or cable | Wires & cables |
| Power a tool, sensor, or remote | Battery | Batteries |
Capacitors: match the type, microfarads, and voltage
Start capacitors give a motor its initial boost and are active only during startup, run capacitors supply continuous power while the motor operates, and dual capacitors combine both functions in one unit. Our guide to AC capacitors covers symptoms, testing, and replacement.
| Capacitor | Key specs from the listing | Notes |
|---|---|---|
| Lennox 89M97 | Dual run, 55/10 MFD, 440V, round | Listed for Lennox 13ACD and LCS13DC series |
| Hoshizaki 3A0076-11 | Start capacitor, 145-174 uF, 220 VAC | Fit not listed; confirm against the unit label |
Match the microfarad value and type exactly, and never use a lower voltage rating than the original. A reading more than 10 percent below the rated microfarads is a common reason to replace a capacitor. Capacitors can hold a charge after power is cut, so discharge them safely first. Browse capacitors.
Breakers, lugs, and panel parts
| Part | Key specs from the listing | Notes |
|---|---|---|
| Siemens MBKQR3200HA | Breaker mounting kit, 240 VAC, 3-phase, 65 kA, includes HQR23B200 breaker | For Siemens P1 panelboards; confirm panel revision |
| Square D HOML2225 | 2-pole, 225 A sub-feed lug, wire range AWG 1 to 300 kcmil, copper or aluminum | Distributes power without overcurrent protection; for Homeline load centers; confirm mounting |
| Leviton LFTLA | Feed-through lug, 3 AWG to 300 kcmil, copper or aluminum, plug-on | Load center accessory |
| ICM Controls ICM493 | Line voltage monitor, 230 VAC, 40 A, surge protection, NEMA 3R | For mini-splits and similar outdoor units |
Breakers are matched by amperage, poles, interrupting rating, and panel type. Sub-feed lugs and kits are not breakers, so check what each listing actually provides. Browse circuit breakers and terminals and wire connections.
Contactors, relays, and sequencers
Relays handle low-power control signals, while contactors carry heavier loads. Our guide to the difference between a relay and a contactor gives about 10 amps as the usual relay limit and 9 amps and above for contactors.
| Part | Key specs from the listing | Use |
|---|---|---|
| Carrier HN52PD024 | 2-pole, 24V, 40A | Heavy loads such as compressors |
| IDEC RH4B-UAC24V | 4PDT, 24VAC coil, plug-in | Control circuits; contact rating not listed |
| White-Rodgers 24A34-2 | 24V control, on 30 to 90 s, off 1 to 30 s, 25 A resistive, 3000 W, multi-poise | Staging electric heat strips |
Check that the control voltage matches the coil rating, and match the contacts to the load. Browse contactors, relays and switches, and sequencers.
Disconnects and meter sockets
For air conditioning equipment, the National Electrical Code calls for the disconnecting means to be within sight of and readily accessible from the equipment, where within sight means visible and not more than 50 feet away. Outdoor enclosures should be weatherproof, such as NEMA 3R. Our guide to choosing an AC disconnect box covers fusible and non-fusible types.
| Item | Key specs from the listing | Notes |
|---|---|---|
| Mars 83321 | 60A, 240V, NEMA 3R, steel enclosure, non-fused, three-phase | Pole count not listed |
| Milbank U6281-XL-200-5T9 | 200 A, 1 phase, up to 240 VAC, 5 jaws, Type 3R, lever bypass, overhead or underground | Meter socket with main and load center |
| Milbank U4413-O-KK-BLG | 200 A, 600 V AC, 4 terminals, ringless, surface mount | Meter socket |
| Milbank U1797-O-K3L-K2L | 320 A, 1 phase, 600 V AC, 4 jaws, lever bypass, underground, Type 3R | Meter socket |
Utilities set their own meter socket requirements, so confirm them before you order. Have a licensed electrician install disconnects and meter sockets. Browse disconnects.
Fuses, transformers, and timers
| Part | Key specs from the listing | Notes |
|---|---|---|
| Mars 82409 | 5 A, 250 V, fast acting, 1/4 x 1-1/4 inch | Small cartridge fuse |
| Allied 69M58 | 200 A, 250 V | Fuse class not listed |
| Carrier HT01CN241 | 40 VA, 208 and 230 V primary, 24 V secondary | About 1.7 A at 24 V |
| Mars 32391 | 240 VAC, 50/60 Hz, 0.1 to 8 minute adjustable delay | Time delay |
| Intermatic T1471BR | 24-hour mechanical time switch, 4PST, 40 A per pole, 120 V, NEMA 3R | Daily schedule switching |
A fuse is a one-time device that must be replaced after it opens, while a breaker can be reset. Match the current, voltage, type, and size on the fuse, and size a transformer by dividing VA by volts. Browse fuses, transformers, and timers.
Wires and cables
Wire size depends on the circuit. For copper conductors, the National Electrical Code limits overcurrent protection on small conductors to 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG, and other rules for ambient temperature and conductor count can apply.
| Cable | Key specs from the listing | Use |
|---|---|---|
| Lionbeam LB-W1645SSW | 16 AWG, 4 stranded copper conductors, overall shield, CMR, white PVC jacket, 500 ft pull box | Shielded control and signal wiring |
| Rectorseal DUCKTSTRIPUNV250 | 5 conductors: two 16 AWG stranded signal, one 14 AWG solid ground, two 14 AWG stranded power, 250 ft | Power and control between mini-split outdoor and indoor units |
Check the jacket rating, conductor count, and gauge against the equipment instructions. Browse wires and cables.
Batteries
| Battery | Key specs from the listing | Notes |
|---|---|---|
| Rayovac ALD-12 | D alkaline, 1.5V, 12 pack, 7500 mAh | General use |
| Energizer EN22 | 9V industrial alkaline, 600 mAh, 5 year shelf life | Pack count not listed |
| Duracell DL2032B4PK | 3V lithium coin cell, size 2032 | Sold as a 4-pack per the title |
| Inficon 703-057-G1 | NiCd battery, 3-pack | For D-TEK refrigerant leak detectors |
Match the size, voltage, and chemistry to the device. Our guide to rechargeable batteries for HVAC tools and devices covers compatibility and care. Browse batteries.
Before you order: things to check
- Read the ratings on the original part: voltage, amperage, microfarads, poles, and coil voltage
- Confirm the fit or model, since some listings name only certain equipment
- Check the title, the specifications, and the description together, since model details can differ between them
- Match the fuse class and type, not only the amp and voltage rating
- Use a weatherproof enclosure such as NEMA 3R for outdoor disconnects and meter sockets
- Confirm utility requirements before ordering a meter socket
- Turn off and verify power before working, and discharge capacitors safely
- Hire a licensed electrician for panel, disconnect, and service entrance work
- Read the overview in our guide to top HVAC electrical components
Electrical components glossary
- MFD
- Microfarad, the unit that rates capacitance; MFD and uF mean the same thing on a capacitor label. Shop capacitors →
- Dual run capacitor
- A capacitor that serves two motors, such as a compressor and a fan, and is labeled with two values like 55/10 MFD. Shop capacitors →
- Contactor
- An electrically controlled switch that carries high current to loads such as compressors and motors. Shop contactors →
- Non-fused disconnect
- A switch that cuts power to equipment without containing fuses, relying on an overcurrent device elsewhere. Shop disconnects →
- Sequencer
- A time-delay switch that turns electric heat strips on in stages to reduce the electrical load. Shop sequencers →
- VA
- Volt-amps, the rating that shows how much load a transformer can carry; VA divided by volts gives amps. Shop transformers →
- Meter socket
- The enclosure that holds the utility meter, rated in amps and voltage, with jaws that grip the meter blades. Shop disconnects →
Frequently asked questions
What electrical components does Voomi Supply carry?
The range covers twelve areas: batteries, capacitors, circuit breakers, contactors, disconnects, fuses, relays and switches, sequencers, terminals and wire connections, transformers, timers, and wires and cables. Brand collections add parts from Siemens, Eaton, ABB, IDEC, Leviton, Milbank, and others. Browse the full electrical components collection or search by part number.
How do I choose a replacement capacitor?
Read the label on the old capacitor for the capacitance in microfarads, the voltage rating, and the type: start, run, or dual. For example, the Lennox 89M97 is a round dual run capacitor rated 55/10 MFD at 440 volts, while the Hoshizaki 3A0076-11 is a start capacitor listed at 145-174 uF and 220 VAC. Match the microfarad value and type exactly. A higher voltage rating is commonly accepted as a replacement, but a lower one is not.
When should I replace an AC capacitor?
Common signs include a unit that hums but does not start, a bulging or leaking case, and a meter reading that is off the rating. Our capacitor guide recommends replacement if the measured value is more than 10 percent below the rated microfarads. Capacitors can hold a charge after power is cut, so discharge one safely before testing, and leave the work to a trained technician if you are unsure.
What is the difference between a relay and a contactor?
A relay switches low-power control circuits, and our technician guide describes relays as handling currents up to about 10 amps. A contactor switches heavy loads such as compressors and motors, typically at 9 amps and above, and often has three power contacts for three-phase loads. For example, the Carrier HN52PD024 is a 2-pole, 24V, 40A contactor, while the IDEC RH4B-UAC24V is a 4PDT relay with a 24VAC coil. Always match the control voltage to the coil rating.
What is the difference between a fusible and a non-fused disconnect, and where does it go?
A fusible disconnect holds fuses that open the circuit on an overcurrent, while a non-fused disconnect is a switch that relies on an overcurrent device elsewhere, such as a breaker. For air conditioning equipment, the National Electrical Code calls for the disconnecting means to be within sight of and readily accessible from the equipment, and within sight means visible from and not more than 50 feet away. Outdoor installations need a weatherproof enclosure such as NEMA 3R, like the Mars 83321 listing. Browse disconnects by amp rating and enclosure.
Do I still need a disconnect if my unit has a circuit breaker?
Yes. The breaker provides overcurrent protection, but a separate disconnect within sight of the unit lets a technician isolate it safely during service. Always verify power is off before working, even if you believe it is disconnected, and have a licensed electrician handle installation to meet code.
How do I choose the right fuse?
Match the current rating to the circuit, and use a voltage rating equal to or higher than the circuit voltage. Then check the type, such as fast acting or time delay, and the physical size. For example, the Mars 82409 is a 5 amp, 250 volt fast acting fuse that measures 1/4 inch by 1-1/4 inches, and the Allied 69M58 is rated 200 amps at 250 volts but does not list its fuse class, so confirm the class against your equipment.
What wire size do I need for a circuit?
For copper conductors, the National Electrical Code limits overcurrent protection on small conductors to 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG. Aluminum conductors have lower limits, and other rules for ambient temperature and conductor count can apply. Check the wire markings and local code, and browse wires and cables for the type and rating you need.
How do I size a 24V control transformer?
Match the primary voltage to your supply, then choose a VA rating that meets or exceeds the total load on the 24 volt side. Dividing VA by volts gives the maximum current, so the Carrier HT01CN241 at 40 VA and 24 volts can supply about 1.7 amps. It lists 208 and 230 volt primaries. Add up the control loads such as relays, contactors, and the thermostat before you choose.
What does an electric heat sequencer do?
A sequencer staggers the activation of electric heat strips instead of turning them all on at once, which reduces the electrical load and protects components. The White-Rodgers 24A34-2 is a 24 volt sequencer with an on timing of 30 to 90 seconds and an off timing of 1 to 30 seconds, rated 25 amps resistive. Match the control voltage, the time delay, and the contact rating to the original. See sequencers for more.