Plumbing Valves & Valve Parts: Ball, Check, Backflow, Relief & Zone Valves
Voomi Supply carries plumbing valves and valve parts for water supply, hydronic, and commercial piping, including ball valves, backflow preventers, butterfly valves, check valves, gate valves, pressure and relief valves, solenoid valves and coils, zone control valves, and valve repair and rebuild kits, from brands like Watts, Apollo Valves, Caleffi, and A.Y. McDonald. Compare sizes, connections, and pressure ratings on each product page, plus US-based support to help match the right valve or repair kit to your system.
Shop by category
View all plumbing valves →Popular plumbing valves
Shop all plumbing valves →Brands we carry
Which plumbing valve do I need?
Most valve orders start with a job rather than a valve name: shut off a line, stop reverse flow, protect the water supply, lower the pressure, or control flow from a signal. Match the job to the valve type, then check size, connection, and rating on the listing.
| What you need to do | Valve type | Shop |
|---|---|---|
| Shut off a line for service | Ball valve or gate valve | Ball valves and gate valves |
| Isolate a single fixture or appliance | Supply stop or shut off valve | Stop & shut off valves |
| Stop water flowing backward in a line | Check valve | Check valves |
| Protect drinking water from contamination | Backflow preventer assembly | Backflow preventers |
| Lower high incoming pressure | Pressure reducing valve | Pressure & relief valves |
| Protect a boiler or tank from overpressure | Pressure relief valve | Pressure & relief valves |
| Open and close flow from a control signal | Solenoid valve | Solenoid valves & coils |
| Control flow to a heating or cooling zone | Zone control valve | Zone control valves |
| Isolate large diameter piping | Butterfly valve | Butterfly valves |
| Balance, mix, or divert flow | Specialty valve | Specialty valves |
| Fix a leaking valve without replacing it | Repair or rebuild kit | Valve repair & rebuild kits |
Types of plumbing valves compared
The valve body decides how it moves and what it does best. This table compares the main types by how they operate and what to watch for.
| Valve type | How it works | Best for | Watch out for |
|---|---|---|---|
| Ball | A ball with a bore turns 90 degrees to open or close the line | Fast, tight shutoff on water and hydronic lines | Lacks fine control in throttling, so use it fully open or fully closed |
| Gate | A wedge-shaped gate is raised or lowered by a handwheel over several turns | Lines that stay open or closed for long periods | Meant for shutoff rather than regulation; a partly open gate can vibrate |
| Check | A disc or flapper opens with forward flow and closes on its own against reverse flow | Stopping backflow in pump discharge and supply lines | A swing check that slams shut can cause water hammer |
| Butterfly | A disc on a stem turns a quarter turn inside the pipe | Larger diameter lines, with a lighter body that needs less support | Wafer styles need flanges on both sides; confirm seat material and temperature range |
| Solenoid | An electric coil opens or closes the valve when energized | Automatic on and off control from a thermostat, timer, or controller | Check whether it is normally open or normally closed, plus coil voltage and media |
| Zone control | A motorized valve that opens and closes flow to one hydronic zone | Zoned hydronic heating and cooling systems | Confirm voltage, 2-way or 3-way, normally closed, and sweat or threaded ends |
| Pressure reducing | Holds downstream water pressure at a set value below the supply pressure | Buildings with high incoming pressure | Setting range, size, and thermal expansion control must match the system |
| Relief | Opens at a set pressure to discharge water and protect the system | Boilers, water heaters, and closed loops | A safety device; if it discharges, something needs attention |
Backflow preventers: which assembly fits the hazard
A backflow preventer keeps contaminated water from reversing into the clean supply. Backsiphonage happens when supply pressure drops and draws water backward, and backpressure happens when downstream pressure rises above the supply. The assembly you need depends on which of the two can occur and on how hazardous the connection is.
| Assembly | Standard | Protects against | Typical use |
|---|---|---|---|
| Reduced pressure (RP or RPZ) | ASSE 1013 | Backpressure and backsiphonage | Low or high hazard connections; can be used under continuous pressure |
| Double check valve assembly (DCVA) | ASSE 1015 | Backpressure and backsiphonage | Low hazard only; often used with fire protection equipment or when supplying boilers |
| Pressure vacuum breaker (PVB) | ASSE 1020 | Backsiphonage only | Low or high hazard; installed at least 12 inches above downstream piping |
| Atmospheric vacuum breaker (AVB) | ASSE 1001 | Backsiphonage only | Not for continuous pressure; no valves downline; cannot be field tested once installed |
A reduced pressure assembly has two independently acting check valves with a relief valve between them, and that relief valve may discharge intermittently, so an indoor installation should have the relief port air gapped to a drain. The Watts 1LF009M2-QT-FS is a 1 inch lead-free reduced pressure zone assembly with quarter turn shutoff valves, and the Wilkins 975XL2-1 is a 1 inch wye pattern assembly with a bronze body and separate access to the checks and relief valve.
Assemblies need periodic testing and repair parts, and local rules set the schedule. When a check or relief valve wears out, a matched kit such as the Watts 0887793 total repair kit is listed for 1 inch Watts 009 and LF009 assemblies. Browse the full range of backflow preventers by size and type.
Pressure reducing and relief valves
High incoming pressure wears fixtures and appliances, which is why plumbing codes limit it. Codes based on the International Plumbing Code commonly cap pressure in building water piping at 80 psi, and call for an approved pressure reducing valve on the building water service near its entrance when supply pressure is higher, though your local code governs. The Caleffi 535361HA shows what to look for on a listing: a 1 inch FNPT forged brass body, a 15 to 90 psi setting range with a 45 psi factory setting, a 300 psi max working pressure, a 180 F max working temperature, and a 19 gpm flow rate, with ASSE 1003, CSA B356, NSF 61, and NSF 372 listed. Backflow preventers and some pressure reducing valves can close the system, and water that expands when heated then has nowhere to go, so piping must be relieved of excess pressure from thermal expansion with an expansion tank or a relief device.
Relief valves are the last safeguard against overpressure. Residential water heater temperature and pressure relief valves are typically designed to relieve at 150 psi and 210 F, and the Bell & Gossett 110129 is a 1 inch NPT brass relief valve listed at 30 psi and 1,170,000 BTUH, up to 225 F, and designed to ASME Section IV for heating boilers. Normal operation should not discharge any water, so a relief valve that discharges may indicate an unsafe temperature or pressure condition that needs a qualified technician. See all pressure and relief valves by set pressure, size, and connection.
Solenoid and zone control valves
Electric valves open and close a line from a control signal. A solenoid valve uses an electric coil, and it is normally closed if it is closed when the coil is not energized, or normally open if it is open when the coil is not energized. Zone control valves apply the same idea to hydronic loops, opening and closing flow to a heating or cooling zone. The Honeywell V8043F5036 is a 24V, 2-way, normally closed, 3/4 inch sweat zone valve with a 3.5 Cv flow rating and a 20 psi close off rating as listed. Industrial solenoids carry media limits, such as the ASCO 8263H304, a 3/8 NPT valve listed for 0-125# steam and 0-210# water, so always match the media, pressure, and coil voltage to your system. Browse solenoid valves and coils and zone control valves by voltage and connection.
Valve materials and connections
Material and connection decide whether a valve fits your pipe and your fluid. This table shows how common options line up with valves in our range.
| Material or connection | Where it fits | Example from our range |
|---|---|---|
| Brass, threaded (NPT or IPS) | Water supply and general plumbing lines with threaded pipe | Soval 620-005T, a 1/2 inch brass threaded gate valve IPS |
| Compression | Fixture supply lines that connect to tubing | Dahl 511-32-31, a lead-free supply stop with 1/2 inch OD by 3/8 inch OD compression ends and quarter turn operation |
| Sweat (solder) | Copper tube systems, common on hydronic zone valves | Honeywell V8043F5036, a 3/4 inch sweat zone valve |
| Grooved | Larger piping joined with grooved couplings instead of threads | Victaulic V-030-761ST-2, a 3 inch grooved butterfly valve with a ductile iron disc, 300 psi, and 10 to 150 F |
| PVC wafer | Plastic piping systems that need a corrosion resistant body | Soval 405-030, a 3 inch PVC wafer style butterfly valve |
How to read a valve listing
Valve pages carry a handful of numbers that decide fit. This table explains what each one means and where it shows up in our range.
| Term | What it tells you | Example listing values |
|---|---|---|
| Cv | Flow capacity: the US gallons per minute of water at 60 F that pass through a fully open valve with a 1 psi pressure drop. A higher Cv passes more flow at the same drop | Victaulic V-030-761ST-2: 440 Cv. Honeywell V8043F5036: 3.5 Cv |
| Pressure rating | The pressure the valve is built for. Check whether it is a working pressure, a close off pressure, or a setting range, and keep it above your system pressure | Caleffi 535361HA: 300 psi max working. Honeywell V8043F5036: 20 psi close off. Victaulic: 300 psi |
| Temperature rating | The fluid temperature range the valve and its seals can handle | Bell & Gossett 110129: up to 225 F. Caleffi 535361HA: 180 F. Victaulic: 10 to 150 F |
| Connection type | How the valve joins the pipe: threaded, sweat, compression, grooved, or wafer between flanges | Dahl 511-32-31: compression. Honeywell V8043F5036: sweat. Victaulic: grooved |
| Lead-free and NSF listings | For drinking water lines, federal law limits lead in wetted surfaces to a weighted average of 0.25 percent | Caleffi 535361HA: NSF 61 and NSF 372. Dahl 511-32-31: lead-free |
| Normally closed (NC) | The valve stays closed until its coil is energized | Honeywell V8043F5036: Normally Closed |
Repair or replace: common valve problems
Many valve problems come from worn internal parts rather than a failed body. Our guide to common valve issues and how to rebuild them lists the usual causes.
| Symptom | Common cause | What to look at |
|---|---|---|
| Leaking from the valve | Worn seals, gaskets, or packing, made worse by temperature, pressure, and corrosive fluids | Seals, gaskets, O-rings, and packing in a kit |
| Stiff or stuck handle | Debris, corrosion, or mineral deposits on the stem or seat | Stem and seat condition |
| Poor shutoff | Seat damaged by impact, debris, or wear | The valve seat |
| Weeping around the stem | Packing around the stem that has worn, dried, or cracked | The stem packing |
| Automated valve will not move | Electrical, pneumatic, or hydraulic fault in the actuator | The actuator and its controls |
| Noise or vibration | Cavitation, water hammer, or worn components | Worn parts and flow conditions |
How to rebuild a leaking valve
- Shut off the system and relieve pressure.
- Remove the valve from the system if necessary.
- Disassemble the valve following the manufacturer's instructions, and keep track of the parts.
- Clean all components and inspect them for dirt, corrosion, and old lubricant.
- Replace worn components with parts from a kit that matches the valve's make and model, and replace a damaged seat.
- Lubricate moving parts with a lubricant the manufacturer approves.
- Reassemble the valve.
- Reinstall and test. Restore pressure, then check for leaks and correct operation.
Kits are specific to a valve model, so match the kit to the valve before ordering. Browse valve repair and rebuild kits by brand and part number.
Before you order: things to check
- Confirm the fluid: potable water, hydronic water, or steam, and check that the listing covers it, since ASCO lists steam and water pressures separately
- Match size and connection type to your pipe, such as 3/4 inch sweat or 3 inch grooved
- Check pressure and temperature ratings against your operating conditions
- For drinking water lines, look for lead-free and NSF listings on the product page
- Follow the flow direction marked on the body of check valves, pressure reducing valves, and backflow assemblies
- For backflow assemblies, confirm what your water provider requires for approval and testing
- Check the lead time and return terms on each listing, since stock and shipping vary
Plumbing valves glossary
- Backflow preventer
- A device that stops water from flowing backward into the clean supply, built as a reduced pressure assembly, a double check assembly, or a vacuum breaker. Shop backflow preventers →
- Check valve
- A valve that lets fluid flow in one direction only and works automatically, with no handle or controller. Shop check valves →
- Quarter-turn valve
- A valve that goes from fully open to fully closed with a 90 degree turn, such as a ball valve or a butterfly valve. Shop ball valves →
- Pressure reducing valve
- A valve that lowers high incoming water pressure to a set value downstream. Shop pressure & relief valves →
- Normally closed (NC)
- A solenoid or zone valve that stays closed until its coil is energized. Shop zone control valves →
- Wafer valve
- A valve body that sits between two pipe flanges and is held by long through-bolts, unlike a lug valve, which bolts to each flange separately. Shop butterfly valves →
- Rebuild kit
- A set of replacement internal parts, such as seals, gaskets, O-rings, packing, and seats, matched to a specific valve model. Shop valve repair & rebuild kits →
Frequently asked questions
What is the difference between a ball valve and a gate valve?
A ball valve turns a ball with a bore through 90 degrees, so it opens or closes with a quarter turn and seals tightly. A gate valve raises and lowers a wedge-shaped gate with a handwheel over several turns, so it operates more slowly and is meant for shutting flow off rather than regulating it. A partly open gate can vibrate, and a ball valve lacks the fine control of other valve types in throttling, so use either one fully open or fully closed. Our guide compares the two on operation, sealing, maintenance, and cost: gate valves vs ball valves.
Which backflow preventer do I need?
The right assembly depends on the hazard level and on whether backpressure is possible. A reduced pressure assembly (ASSE 1013) protects against both backpressure and backsiphonage and can be used on low or high hazard connections. A double check valve assembly (ASSE 1015) also protects against both but is for low hazard only. Pressure vacuum breakers (ASSE 1020) and atmospheric vacuum breakers (ASSE 1001) protect against backsiphonage only, so they suit connections where backpressure cannot occur. Your local water authority decides which assembly is approved for each connection, so confirm before you buy. Browse backflow preventers by size and type.
How often does a backflow preventer need to be tested?
The Minnesota Department of Health lists annual testing for reduced pressure assemblies, double check valve assemblies, and pressure vacuum breakers, while an atmospheric vacuum breaker cannot be field tested once installed. Mechanical assemblies are tested with calibrated gauge equipment by a certified individual, and testing is also required when an assembly is installed, relocated, or repaired. Local rules set the actual schedule, so check with your water provider before planning a test.
When do I need a pressure reducing valve?
Install one when incoming water pressure is higher than your fixtures and appliances should see. Plumbing codes based on the International Plumbing Code commonly limit pressure in building water piping to 80 psi, and call for an approved pressure reducing valve on the building water service near its entrance when supply pressure is higher, though your local code governs. Check the setting range on the listing: the Caleffi 535361HA, for example, adjusts from 15 to 90 psi and has a 45 psi factory setting. Piping must also be relieved of pressure from thermal expansion, so confirm whether the system needs an expansion tank or a relief device.
What does a check valve do and where does it go?
A check valve lets fluid flow in one direction only and works automatically, with no handle or controller. Swing checks use a hinged disc, lift checks raise a disc off its seat, and spring-loaded checks open once upstream pressure overcomes the spring, which is known as the cracking pressure. A swing check that slams shut when flow stops can cause water hammer, which can damage pumps, valves, and pipes. Install a check valve with the flow direction marked on its body, and compare sizes and styles in check valves.
What do Cv and pressure ratings mean on a valve listing?
Cv is a flow capacity number: the US gallons per minute of water at 60 F that pass through a fully open valve with a 1 psi pressure drop, so a higher Cv passes more flow at the same drop. For example, the Victaulic V-030-761ST-2 butterfly valve lists 440 Cv, while the Honeywell V8043F5036 zone valve lists 3.5 Cv. Pressure ratings are a separate number. Read whether the figure is a working pressure, a close off pressure, or a setting range, and keep it above the pressure in your system.
Can I rebuild a valve instead of replacing it?
Often yes, when the problem is worn internal parts. Our guide lists seals, gaskets, O-rings, packing material, and valve seats, sometimes with springs, as the usual kit contents, and says to match the kit to the valve's make and model. Shut off the system and relieve pressure first, and follow the manufacturer's instructions. Relief valves are safety devices, and a relief valve that discharges may indicate an unsafe temperature or pressure condition, so have a qualified technician look at the system. Browse valve repair and rebuild kits by brand and model.
What does lead-free mean on a plumbing valve?
Since January 4, 2014, federal law has limited lead in pipes, fittings, and components used for drinking water to a weighted average of 0.25 percent across wetted surfaces. Valves for potable water should state lead-free or low lead construction on the listing, and many also list NSF/ANSI 61, as the Caleffi 535361HA does along with NSF 372. Valves used only for non-potable purposes such as irrigation or industrial processing are exempt, so check the listing before you put a valve on a drinking water line.
Should I choose a wafer or lug butterfly valve?
A wafer valve sits between two flanges and is held by long through-bolts, so the body has to be centered before the bolts are tightened, and it cannot hold pressure from one side if the other flange is removed. A lug valve bolts to each flange separately, so it suits dead end service and is more forgiving to install, but it can cost more. For example, the Soval 405-030 is a 3 inch PVC wafer style valve, and the Victaulic V-030-761ST-2 is a 3 inch grooved butterfly valve. Browse butterfly valves by size and material.
How fast do valves ship?
Many in-stock listings state that they ship same day if ordered by 12 pm, but lead times vary by product. For example, the Dahl 511-32-31 supply stop shows 5 to 6 business days, and the ASCO 8263H304 solenoid valve shows 4 to 5 weeks. Check the lead time and return terms on each product page, and contact us with the part number if you need to match a part or confirm availability.