Part |
What it does |
What to match |
|
Replacement cell |
Wears out in service and is swapped on a schedule set by the manufacturer. RGF, for example, lists the REME HALO cell as recommended after 2 years. |
The purifier brand and model, since cells are model-specific (RGF PHIC-RH for REME-HALO, PHIC-QR5 for Guardian Air QR+ 5, Aerus US71088 for Air Scrubber units) |
|
Mesh insert or catalyst media |
Replaces the media element in a photocatalytic or similar in-duct air cleaner |
The cleaner model and size range (Lennox X8792 PureAir insert for PCO 16-28) |
|
Electronic air cleaner cell or pre-filter |
Washable collector cells and pre-filters that need regular cleaning rather than a fixed replacement date |
Cell and pre-filter dimensions and the original part number |
|
UV ballast |
Powers and regulates a germicidal UV lamp |
Input voltage and the lamp it drives (Sanuvox BST120/277GL, 120 to 277 V) |
|
UV lamp |
Loses germicidal output over time, so it is replaced on a schedule |
Lamp length, base and wattage from the original lamp |
Intervals depend on the part and the maker, so the manual for your unit always wins. These are the published figures we could verify.
|
Part |
Published guidance |
Source basis |
|
In-duct purifier cell |
RGF recommends replacing the REME HALO cell after 2 years. Other models have their own interval. |
RGF REME HALO spec sheet |
|
UV-C lamp |
Most manufacturers recommend replacement at about 9,000 hours, so many sites replace yearly. A lamp can keep glowing blue after its UV-C output has dropped 20 to 50 percent, so the glow is not a performance check. |
Facilities Net technical article on UV-C lamp replacement |
|
Electronic air cleaner cells and pre-filters |
Set a regular washing schedule and inspect cells and pre-filters during each service. No single interval fits every model. |
Service guidance from an HVAC contractor FAQ |
|
Rule |
Detail |
|
Power down first |
Turn off the heating and cooling system and the air cleaner, wait 30 seconds, then remove the access door and pull the cells and pre-filters. |
|
Wash gently |
Use hot water with automatic dishwasher detergent, a dishwasher with the cells resting on upside-down glasses, or a garden hose. Do not bend the collector plates and wipe the ionizing wires gently. |
|
Skip the drying cycle |
Never run cells through a dishwasher drying cycle, because residue can bake on. Do not use coil cleaners or contact cleaners. |
|
Dry fully |
Let cells and pre-filters air-dry completely before reinstalling and restoring power. |
Always follow the cleaning steps in your own manual if they differ.
|
Check |
What to compare |
|
Unit brand and model |
The nameplate or manual of the air cleaner, purifier or UV system |
|
Part number |
The OEM number on the old part, or the model named in the listing title |
|
Voltage |
The supply voltage of ballasts and power parts (RGF lists the REME HALO at 24 VAC/DC; Sanuvox ballasts are listed at 120 to 277 V) |
|
Size |
Cell, filter and lamp dimensions from the old part |
|
Technology |
Ionization or photocatalytic cell, electronic collector cell or UV lamp. These are not interchangeable. |
Browse the full categories: air cleaners & purifiers, ionizers, UV lights, smoke eliminators and residential air filters.
Not sure what part you need? Our team can help you identify the correct air cleaner replacement parts for your unit, so you can order with confidence.