Voomi Supply carries replacement motors for furnaces, air handlers, and outdoor units, including blower motors, condenser fan motors, draft inducer motors, programmed ECM motors, split phase motors, and variable speed motors, plus motor parts and accessories. Brands include Genteq, Goodman, Mars, and Century Motors. Compare horsepower, voltage, speed, and frame on each product page, and send us the nameplate or OEM part number if you need help matching a motor.
Start with where the motor sits in the system and what it drives. The application points to the category, and the nameplate settles the exact model.
| What the motor does | Motor type | Shop |
|---|---|---|
| Moves air through the furnace or air handler | Blower motor | Blower motors |
| Moves air across the outdoor coil | Condenser fan motor | Condenser fan motors |
| Exhausts combustion gases on a gas furnace | Draft inducer motor | Draft inducer motors |
| Replaces a model-specific ECM blower motor | Programmed ECM motor | Programmed ECM motors |
| Holds airflow steady as load changes | Variable speed motor | Variable speed motors |
| Drives a belt drive fan or blower at a fixed speed | Split phase motor | Split phase motors |
| Replaces an X13 type motor | Evergreen motor | Evergreen motors |
| Needs a capacitor, belt, pulley, or bracket | Motor part or accessory | Motor parts & accessories |
Most older HVAC motors are induction motors. A PSC motor uses a run capacitor and runs at fixed speeds, and a split phase motor is a single-phase induction motor with higher starting torque and a lower initial cost, which suits belt drive fans that do not need continuous high torque. An ECM is a brushless motor with built-in electronics, so it adjusts its speed to the load instead of running at full speed all the time. That is why ECM blower motors can hold airflow steadier, cut energy use at partial load, and reduce startup wear. The trade-off is that an ECM costs more and typically needs a matching control module or programming to match the equipment. X13 type ECMs hold a fixed torque, so airflow still changes with duct pressure, while full ECMs adjust speed to keep airflow constant. Compare the full range of programmed ECM motors and split phase motors before you decide.
| Nameplate item | What to check |
|---|---|
| Voltage | Must match the supply, for example 115V, 208/230V, or dual voltage 115/230V |
| Horsepower | For induction replacements, match the original horsepower exactly |
| Speed (RPM) | Match for induction motors; ECM replacements can use different RPM and amperage ratings, so follow the replacement guide |
| Frame | NEMA 48 has a 1/2 inch shaft and NEMA 56 a 5/8 inch shaft, so the frame also tells you the shaft size |
| Rotation | Check clockwise, counterclockwise, or reversible against the original |
| Shaft and mounting | Confirm shaft diameter and length, and the mounting style, such as resilient base or belly band |
| Capacitor | PSC motors need the right run capacitor, so verify the rating when you replace the motor |
| OEM part number | The fastest way to confirm a fit; we can cross-reference it for you |
ECM replacements come in more than one form. Model-specific OEM motors, such as the Goodman 0131M00728S, which is listed as programmed for Goodman equipment and compatible with the ASPT25B14AA air handler, are the safest match for the equipment they were made for. The Trane MOT15162 is another programmable ECM at 3/4 HP and 115/230V. Universal-style replacements are designed to substitute for several OEM models: the Genteq 6105E Evergreen motor is listed as a 1/2 HP, 115V, five-speed motor with a NEMA 48 frame that replaces OEM X13 motors without complicated programming. For outdoor fans, the manufacturer's replacement guide states that constant speed ECM outdoor fan motors must be replaced with an OEM part from the maker of the equipment, while induction outdoor motors only need to match voltage and horsepower. The Mars 10866 is listed as an ECM condenser fan motor from 3/4 to 1 HP at 115/230V that connects like a PSC motor without a capacitor. Always compare the replacement's listing against your OEM part number before ordering.
The main types are indoor blower motors, outdoor condenser fan motors, and draft inducer motors on gas furnaces. Within those, motors differ by technology: PSC and split phase induction motors run at fixed speeds, while ECM motors are brushless and adjust their speed electronically. Specialty motors cover high-torque and custom applications. Each type is listed by horsepower, voltage, speed, and frame, so match those ratings before choosing.
Read the nameplate on the motor you are replacing. Note the horsepower, voltage, rotation, shaft and mounting style, and for belt drive motors the frame size, such as NEMA 48 or 56. Also note the manufacturer part number, because OEM and cross-reference numbers are the fastest way to confirm a fit. For induction motors, horsepower and voltage should match exactly. If the label is unreadable, send us the equipment model number and a specialist will help you identify the right motor.
Not automatically. An ECM motor has built-in electronics and often needs matching controls or programming, so it is not simply a more efficient version of a PSC motor. Some replacement ECMs are made to drop into specific OEM motor models, and the listing states which. Because ECM blower motors typically need matching control modules to operate properly, confirm compatibility before ordering and see the variable speed motors collection for options.
Generally yes. A PSC motor runs at fixed speeds and relies on a run capacitor, while an ECM motor adjusts its speed to match the load, which cuts energy use at partial load and reduces startup wear. Efficiency is only part of the picture, since an ECM costs more up front and must be matched to the equipment it serves. Variable speed models also hold airflow steadier, which can improve comfort. Compare your options in programmed ECM motors.
An X13 type motor holds a fixed torque, so airflow changes as duct static pressure changes, and it is a common budget upgrade from a standard motor. A full ECM has a built-in computer that adjusts speed to keep airflow constant regardless of static pressure. Some replacement motors are designed to replace OEM X13 motors without complicated programming, such as the Genteq 6105E listed under Evergreen motors. Always confirm the replacement against the OEM part number.
Motor replacement involves line voltage, capacitors that can hold a charge after power is off, and sometimes gas furnace components, so it is best left to a qualified HVAC technician. At minimum, switch the equipment off at the thermostat and at the service disconnect, discharge and verify any capacitor with a multimeter, and use insulated tools and eye protection. Wiring, rotation, and mounting must match the manufacturer's instructions. If anything looks damaged, stop and call a professional.
Keep the motor and its surroundings clean, replace the air filter on schedule, and listen for new noises, which are often the first sign of bearing wear. Some motors, such as the Century GK2104DV1, have sleeve bearings that follow the manufacturer's lubrication guidance, while others use a sealed ball bearing system. Check the capacitor and fan blade or blower wheel whenever the motor is replaced, since a weak capacitor or an unbalanced wheel shortens motor life. Find capacitors, belts, pulleys, and brackets in motor parts and accessories.
Select in-stock motors ship the same day when ordered by 12 pm, and some listings offer same-day delivery in the Greater Chicago area for orders placed before 4 pm CT, Monday to Friday. To confirm a fit, compare the nameplate and OEM part number against the listing, and contact us with the equipment model number if anything is unclear. Check the return terms on the product page before you order.