A semi-hermetic compressor features a sealed housing that can be opened for servicing, unlike fully hermetic units. The housing is bolted rather than welded, so parts can be repaired or replaced without replacing the whole compressor.
These compressors are widely used in:
|
Type |
Shell and motor |
Serviceability |
Shaft seal |
|
Hermetic |
Fully welded and sealed; the motor and compressor share the refrigerant atmosphere |
An internal failure means replacing the whole unit |
None, because the shell is sealed |
|
Semi-hermetic |
Motor and compressor sit inside a bolted housing that holds refrigerant and oil |
Motor, valve plate, crankshaft and bearings can be repaired or replaced in the field |
None, which reduces leak potential |
|
Open-drive |
The motor is external to the compressor body and is not exposed to refrigerant or oil |
The highest serviceability, with a larger footprint |
An external shaft seal, which is a potential refrigerant leak point |
Listing titles pack the key ratings into a few lines. Confirm each one on the product page and against the nameplate of the system you are repairing.
|
Detail |
What the listings show |
What to check |
|
Compressor type |
Titles say Semi-Hermetic, and some name the Discus series |
The type, because a hermetic unit cannot be repaired in the field |
|
Horsepower |
Ratings such as 1.5 HP, 25 HP and 27 HP |
The horsepower of the compressor you are replacing |
|
Capacity |
BTU or BTUH figures, from about 4,000 to 123,000 |
The rating conditions on the data sheet, since the title does not state them |
|
Voltage and phase |
115V single-phase, 208/230V, 230V three-phase and 460V three-phase |
The electrical supply at the equipment |
|
Refrigerant |
R-22, R-404A and R-502 appear in titles |
The refrigerant on the system nameplate |
|
Temperature application |
Some titles name Medium Temperature |
Whether the application is air conditioning, medium or low temperature refrigeration |
Several listings in this collection are for R-22 systems. The EPA phased out HCFC-22 production and import in the United States as of January 1, 2020, but the rules for using it depend on the system.
|
Situation |
What the EPA says |
|
System manufactured before 2010 |
Virgin HCFC-22 may still be used to service it, and replacement or conversion is not required. |
|
System manufactured on or after January 1, 2010 |
Virgin HCFC-22 may not be used. |
|
Recovered or reclaimed R-22 |
It remains available and legal to use after the 2020 phaseout. |
|
Expanding capacity |
Expanding a system generally makes it a new system, so only recovered or reclaimed R-22, or an alternative refrigerant, may be added. |
|
Factor |
What to check |
|
Application type |
Determine whether the compressor will be used for HVAC, refrigeration, or industrial cooling. |
|
Capacity and pressure |
Select a compressor that matches your system's cooling capacity and pressure requirements. |
|
Electrical supply |
Match the voltage and phase to the equipment, for example 115V single-phase or 460V three-phase. |
|
Refrigerant |
Ensure the compressor is approved for your system's refrigerant, and check the manufacturer's specifications. |
|
Serviceability |
A semi-hermetic compressor can be repaired in the field, which matters where uptime is critical. |
|
Model number |
Compare the model number and nameplate data of the compressor you are replacing. |
Choosing the right supplier ensures quality, reliability, and long-term value.
Browse more air conditioning compressors, including reciprocating compressors, scroll compressors, rotary compressors, complete compressor kits, crankcase heaters and compressor parts & accessories.