HVAC Supplies: Refrigerant, Ductwork, Copper Tubing & Installation Materials

Voomi Supply carries the supplies that go around the equipment on every HVAC job, including condensate pumps, copper tubing, line sets, flex duct, ductwork and sheet metal, dampers, and electric heat kits and strips, plus refrigerant and detectors. Brands include RectorSeal, Mueller, ATCO, and Quietflex. Browse in-stock items with specifications on each product page, plus US-based support to help match the right supply to your job.

Why buy from Voomidatasheet
CategoriesPumps, tubing, duct, dampers, heat kits & refrigerant
DuctFlex duct and galvanized trunk duct
HeatingElectric heat kits from 5 kW to 15 kW
ShippingSame-day on select items ordered by 12 pm
BrandsRectorSeal, Mueller & more
Find your supply or part number
Same-DayDispatch on select items ordered by 12 pm
9 CategoriesCondensate pumps to refrigerant
LTL FreightBulky items ship in 1-3 business days
Specs ListedSizes, ratings and compatibility on each product page
US SupportHelp matching supplies to your job

Shop by category

View all HVAC supplies →

Popular HVAC supplies

Shop all HVAC supplies →

Brands we carry

Which supply do I need?

Most HVAC supply orders start with a job step, such as running refrigerant lines, moving air, draining water, or adding heat. Match the step to the supply and the category follows.

What you need to doSupplyShop
Connect indoor and outdoor unitsLine set or copper tubingLine sets and copper tubing
Charge or service a systemRefrigerantRefrigerant
Connect a trunk line to a registerInsulated flex ductFlex duct
Build or extend the main duct runGalvanized trunk duct and fittingsDuctwork & sheet metal
Send air to separate zonesZone damperDampers
Drain condensate uphill or over distanceCondensate pumpCondensate pumps
Add electric heat to an air handlerHeat kitElectric heat kits & strips
Monitor air quality or leaksDetectorDetectors

Choosing ductwork and insulation

Flexible duct and rigid sheet metal do different jobs. Rigid galvanized duct such as the Southwark TD601810 trunk duct, a 26 gauge, 18 by 10 inch section that is 60 inches long, suits main runs, while flexible duct such as the Atco UPC 036 flex duct connects the trunk to registers in tight spaces. Look for UL 181 Class 1 on factory-made duct, which describes how the duct material behaves in a fire, and check the insulation R-value on the listing. The ATCO UPC 036 is rated R-6.0, and the ATCO line is also offered in R-4.2 and R-8.0. The model energy code (IECC) sets minimum duct insulation of R-8 for ducts of 3 inches or more in attics and R-6 in other unconditioned spaces, though the code adopted in your area governs, so confirm it with your local authority. Bare rigid duct and exposed flex in an attic or crawlspace can be wrapped with an insulation sleeve such as the Quietflex SS0680, an R8.0 sleeve for 6 inch duct. Finally, seal joints with closure products listed for the duct type: UL 181B markings cover flexible and metal duct, while 181A is for fiberglass duct board.

Copper tubing and line sets

Refrigerant lines should use tube made for the job. ACR tubing follows ASTM B280, ships cleaned and capped, and is sized by outside diameter, while plumbing copper such as Type L is sized by a nominal diameter, so the same marked size does not match. A line set pairs a larger insulated suction line with a smaller liquid line, and its diameters and length must suit the equipment and the manufacturer's limits. The Mueller 1/2 inch by 50 foot copper roll is described for HVAC, plumbing, and electrical trades, so check the listing for the tube type and sizing before using any copper on a refrigerant circuit. For mini splits, read the guide on choosing the right line set for your mini split before you order.

Refrigerant: what to know before ordering

TopicWhat to know
Who can buyEPA allows refrigerant for stationary equipment to be sold to Section 608 certified technicians, or to employers who show written evidence of employing one
R-22No new production or import in the United States since 2020, so service relies on reclaimed and recycled supply
R-410AA blend of R-32 and R-125 that runs at about 60 percent higher pressure than R-22 and is for equipment designed for it; the listing calls for POE oil
InterchangeabilityRefrigerants are not interchangeable. Use the type shown on the equipment nameplate
VentingIntentional venting of refrigerants is prohibited, so plan for recovery equipment
CylindersListed as bulk cylinders (30 lb R-22, 25 lb R-410A), classified as hazardous material, final sale, with a minimum order of 10 units

Condensate drainage basics

Every cooling system produces water, and a drain that cannot work by gravity needs a pump. The International Mechanical Code sets a minimum slope of 1/8 inch of fall per foot of horizontal run, a 3/4 inch minimum drain line, and secondary protection such as a secondary drain line or an overflow switch. Many installers use more slope for reliability. A pump collects water in a reservoir, a float switch starts it at a set level, and a check valve keeps water from flowing back. The RectorSeal 83909 Aspen Universal Mini Kit is listed for 100 to 250 V AC, 49 feet of maximum lift, and 3.2 gallons per hour, which suits mini split and other small systems. Larger central systems need higher flow, and the full range is in condensate pumps. Our guide to condensate pumps explained covers types and maintenance.

How to choose an electric heat kit

  1. Match the equipment. A heat kit is listed for specific air handlers or packaged units, so start from the model number.
  2. Check the capacity. About 3,412 BTU per hour per kW, so the 8 kW Goodman HKTPD081 adds roughly 27,000 BTU per hour and the 5 kW MRCOOL MHK05B about 17,000.
  3. Check voltage and phase. The Goodman kit is 208/240 V single phase, 60 Hz.
  4. Check the breaker. Some kits include one, such as the MRCOOL MHK05B and the Goodman listing, so confirm what the air handler requires.
  5. Follow the nameplate. Wire and breaker sizes come from the air handler and kit nameplate and the manufacturer's instructions, and electrical work should be done by a qualified professional.

Before you order: things to check

  • Confirm heat kit and damper compatibility with your exact equipment and control system, for example the 24 V AC rating on the zoning damper
  • Check duct diameter, R-value, and UL 181 class on flex duct, and the gauge and dimensions on rigid duct
  • Check tube type and size on copper tubing, and use refrigerant-grade tube for refrigerant lines
  • Confirm the refrigerant type on your equipment nameplate and the minimum order on the cylinder listing
  • Check pump voltage range, lift, and flow against the system size
  • Check shipping and return terms on each listing, since freight items and final sale items differ

HVAC supplies glossary

Condensate pump
A small pump with a reservoir and float switch that moves condensation away from an air conditioner, furnace, or mini split when gravity drainage is not possible. Shop condensate pumps →
Flex duct
Flexible round duct with a wire helix core, insulation, and a vapor barrier jacket, used to connect trunk lines to registers in tight spaces. Shop flex duct →
Trunk duct
Rigid galvanized sheet metal duct that carries air from the equipment to the branch runs. Shop ductwork & sheet metal →
Zone damper
A motorized damper that opens and closes to send conditioned air to one zone of a building. Shop dampers →
Heat kit
A set of electric heating elements installed in an air handler or packaged unit to provide supplemental or primary heat. Shop electric heat kits & strips →
ACR copper tubing
Copper tube made for refrigerant circuits under ASTM B280, sized by outside diameter and supplied cleaned and capped. Shop copper tubing →
Refrigerant
The working fluid that moves heat in an air conditioner or heat pump, sold by type such as R-22 or R-410A and handled under EPA Section 608 rules. Shop refrigerant →

Frequently asked questions

What HVAC supplies should I have on hand for an installation?

Beyond the equipment itself, most jobs need refrigerant line sets or copper tubing, insulation, duct and fittings, and a way to drain condensate, with dampers or heat kits added when the system design calls for them. Installation materials matter more than they look: our own guide notes that performance problems often start with the installation materials rather than the main HVAC part, such as weak sealants, thin insulation, or poor mounting hardware. Compare your list against the job before ordering so the crew is not waiting on a missing fitting, and use HVAC replacement parts for the components that wear out.

Do I need a license to buy refrigerant?

For stationary air conditioning and refrigeration equipment, EPA rules allow refrigerant to be sold only to Section 608 certified technicians, or to an employer who can show written evidence that it employs at least one certified technician. A small exception exists for containers of two pounds or less of motor vehicle refrigerant, but that does not cover home or commercial HVAC refrigerants. Venting refrigerant on purpose is also prohibited under Section 608, so recovery equipment is part of any service job. The refrigerant listings are sold as bulk cylinders with a stated minimum order, so check the quantity and terms on the product page before you order.

Can I still buy R-22 refrigerant?

R-22 can still be used to service existing equipment, but it is no longer produced or imported in the United States. EPA banned new production and import of HCFC-22 starting in 2020, so servicing relies on reclaimed and recycled supply. R-410A is not a drop-in replacement for R-22: the two are different refrigerants with different pressures and oils, and R-410A is for equipment designed for it. If your system is old and expensive to keep running on R-22, it may be worth comparing the cost of repairs with a replacement system.

What is the difference between ACR copper tubing and plumbing copper?

ACR tubing is made for refrigerant systems under ASTM B280 and arrives cleaned and capped so moisture and debris stay out of the circuit. It is sized by outside diameter, while plumbing copper such as Type L is sized by a nominal diameter, so a 1/2 inch ACR tube does not match a 1/2 inch Type L tube. Plumbing tube is not prepared for sealed refrigerant systems, so use ACR or a manufactured line set for refrigerant lines. Always confirm the tube type and size on the product page, and browse copper tubing by size and length.

What does UL 181 Class 1 mean for flex duct?

UL 181 is the standard for factory-made air ducts, and Class 1 means the duct has a flame spread index of not over 25 and a smoke developed index of not over 50. The rating describes how the duct material behaves in a fire, not how well it seals or insulates. For insulation, check the R-value on the listing, since the ATCO line, for example, is offered in R-4.2, R-6.0, and R-8.0, and use closure products listed for flexible duct, which carry UL 181B markings. See the full range of flex duct by diameter.

How do I choose a condensate pump?

Match the pump to the system size and to the lift and distance the water has to travel. Mini split pumps are generally low flow, while central air conditioner and furnace pumps move much more water, and commercial units move more still. The RectorSeal Aspen Universal Mini Kit, for example, is listed with 49 feet of maximum lift, 3.2 gallons per hour, and a 100 to 250 volt input. Plan the drain as well: the International Mechanical Code sets a minimum slope of 1/8 inch per foot and a 3/4 inch minimum drain line, and requires a secondary drain or an overflow switch. Check condensate pumps for flow rates and voltage.

How do I choose an electric heat kit?

Start with the air handler or packaged unit, because a heat kit has to be listed for that exact model. Then check the capacity, the voltage and phase, and whether a breaker is included. The Goodman HKTPD081 is an 8 kW kit for 208/240 volt, single phase, 60 Hz, and the MRCOOL MHK05B is a 5 kW kit with a breaker for MMBV modular blowers. As a rule of thumb, 1 kW of electric heat is about 3,412 BTU per hour, so an 8 kW kit adds roughly 27,000 BTU per hour. The air handler nameplate and installation manual list the kits and breaker sizes allowed. Compare options in electric heat kits and strips.

How are HVAC supplies shipped, and can I return them?

Select in-stock items ship the same day when ordered by 12 pm, while larger items such as trunk duct and refrigerant cylinders ship by LTL freight in 1 to 3 business days, with lift gate service included on those listings. Refrigerant cylinders are classified as hazardous material, and the listings are final sale with a minimum order shown on the page. Some other items, such as the Goodman heat kit, are also final sale with returns accepted only for damaged or defective items. Check the shipping and return terms on each listing, and contact us with the model number if you are unsure about a fit.

Read more