Type |
What it is |
Examples in titles |
|
80% AFUE, single stage |
Non-condensing furnace, usually vented as a Category I appliance |
|
|
80% AFUE, nine speed ECM |
Single-stage burner with a nine speed ECM blower |
|
|
Multi-speed ECM, single stage |
Single-stage burner with a multi-speed ECM blower |
Goodman GMES800603AN and GMES800604BN, 60,000 BTU; GMES960805CN, 80,000 BTU |
|
96% AFUE, condensing |
High-efficiency condensing furnace that extracts extra heat from flue gas |
|
|
Variable speed |
Variable-speed blower, listed as two-stage on the Goodman GCVC96 series |
Goodman GCVC960603BN, GCVC960804CN and GCVC961005CN; MRCOOL MGM80SE090C5A |
A gas forced air furnace uses natural gas or propane to generate heat and distribute it through your home via ductwork. The system heats air in a sealed chamber and then uses a blower fan to circulate warm air evenly throughout every room.
This design ensures fast heating, consistent temperatures, and efficient energy use across the entire space.
A residential gas furnace is one of the most popular heating solutions due to its performance, efficiency, and cost-effectiveness.
Key benefits:
Modern systems are designed to maximize heat output while minimizing energy waste, helping reduce long-term utility costs.
We offer a wide selection of gas heating furnaces designed for different home sizes and performance needs, including:
|
|
80% AFUE (non-condensing) |
90% to 98% AFUE (condensing) |
|
How it vents |
Hot flue gas vents out through a chimney or B-vent as a Category I appliance |
A second heat exchanger cools the flue gas, so it vents through sealed PVC or CPVC as a Category IV appliance |
|
Condensate |
None |
Produces acidic condensate that needs a drain, trap or neutralizer |
|
Venting needs |
Chimney or B-vent |
Plastic vent with sealed joints and a pitch of 1/4 inch per foot back to the furnace |
|
Upfront cost |
Lower |
Higher, with lower fuel use over time |
|
Orientation |
Often multipoise, with upflow, downflow and horizontal |
Some models do not support downflow, so check the listing |
AFUE is the ratio of annual heat output to the fuel consumed, so a 96% furnace turns about 96 percent of the fuel energy into heat for the home.
Modern gas furnaces include advanced technology to improve comfort and energy savings:
Upgrading to a high-efficiency system can reduce energy costs by up to 15–30% over time. Savings are largest when replacing an older 70 to 80 percent unit, and they depend on duct losses and the home envelope.
|
Orientation |
How air moves |
Where it is used |
|
Upflow |
Air enters at the bottom and exits through the top |
Closets and basements |
|
Downflow |
Air enters at the top and exits through the bottom |
Most often attics |
|
Horizontal |
The unit lies on its side with air entering one end and exiting the other |
Attics and crawl spaces |
A multipoise furnace can be installed in more than one position. Trane, for example, makes its 80% models 4-way and its 90%+ models 3-way with no downflow, so always check which positions your model supports.
Choosing the right gas heating furnace depends on several important factors:
Select a system that matches your home size to ensure efficient heating and avoid energy waste. Size from a Manual J load calculation, not from square footage. Compare the output rating, which is input multiplied by AFUE, against the calculated heat loss. An oversized furnace can short cycle, running only about 4 to 8 minutes at a time, while an undersized one runs almost nonstop on the coldest days.
Ensure compatibility with your ductwork, gas supply, and home layout. Condensing models also need a vent run, a condensate drain and a gas type match for natural gas or propane.
A gas forced air furnace is ideal for colder climates due to its ability to produce strong, consistent heat.
Typical timing is shown below. Exact times vary by model, so use the service manual for your furnace.
|
Stage |
What happens |
|
Inducer pre-purge |
The inducer runs for about 10 to 60 seconds |
|
Igniter warm-up |
The hot surface igniter heats for about 10 to 30 seconds |
|
Gas valve trial |
The valve opens for about 4 to 7 seconds while the control looks for flame |
|
Blower on delay |
The blower starts about 30 to 90 seconds after ignition |
|
Blower off delay |
The blower runs about 60 to 120 seconds after the burners stop |
Furnace parts also appear in this category, such as filter bases and inducer motors. Browse related categories: AC & furnace systems, heat pump systems, dual fuel systems, boilers, furnace control boards and ignition control boards.