Switches & Relays: Disconnects, Overload, Fan, Potential & Time Delay Relays

Voomi Supply carries switches and relays for HVAC equipment, motor control, and building systems, including current switches, disconnect switches, overload relays, rollout switches, flow switches, limit switches, fan relays, potential relays, switching relays, and time delay relays. Browse by part type or by brand, including Honeywell, Eaton, ABB, and White-Rodgers. Switches and relays are matched by voltage, current rating, and configuration, so check the specs on each listing.

Why buy from Voomidatasheet
CategoriesDisconnects, overloads, fan relays, flow switches & more
PartsPotential, time delay and switching relays
RatingsCoil voltage, amps and poles on listings
BrandsHoneywell, Eaton & more
ShippingSame-day on select items ordered by 12 pm
Find your switch, relay or part number
Same-DayDispatch on select items ordered by 12 pm
10 CategoriesCurrent switches to time delay relays
Name BrandsHoneywell, Eaton, ABB, Schneider and more
Spec DetailsVoltage, amperage and poles on listings
US SupportPhone, chat and email help

Popular switches & relays

Shop all switches & relays →

Brands we carry

Which switch or relay do I need?

Most orders start with a job: prove a motor is running, isolate equipment for service, protect a motor, or start and stop a fan or compressor. Match the job to the device type, then check voltage, current, and contact configuration on the listing.

What you need to doProductShop
Prove current is flowing in a motor or fan circuitCurrent switchCurrent switches
Isolate equipment for serviceDisconnect switchDisconnect switches
Protect a motor from overloadOverload relayOverload relays
Shut off a furnace if flame rolls outRollout switchRollout switches
Prove water or air is flowingFlow switchFlow switches
Open or close at a set temperature or positionLimit switchLimit switches
Start and stop a blower or fanFan relayFan relays
Drop out a compressor start capacitorPotential relayPotential relays
Switch a load from a control signalSwitching relaySwitching relays
Delay a start or prevent short cyclingTime delay relayTime delay relays

Relays: fan, potential, and time delay

Relays handle control signals and smaller loads, while contactors carry heavier ones. Our guide to the difference between a relay and a contactor gives about 10 amps as the usual relay limit. Match the coil voltage first, then the contacts.

RelayKey specs from the listingUse
White-Rodgers 90-294Q115/120 VAC coil, 2,000 ohm coil resistance, SPDT; contact rating varies on the listingFan relay
Trane RLY196324V, 6A, 60 second on and 120 second off timingCycling fan relay
Mars 19163170 VAC continuous coil, 140 to 153 VAC pickup, 30 to 65 VAC dropout, 3.5 A, 1/4 inch quick connectPotential relay for compressor starting
Copeland 940-0001-62Potential relay kit, up to 115VReplacement for relays in light commercial refrigerant units
IDEC RH4B-UAC24V4PDT, 24VAC coil, plug-in; contact rating not listedControl circuits
Mars 32391240 VAC, 50/60 Hz, 0.1 to 8 minute adjustable delayTime delay
Carrier HK61EA009Solid-state, adjustable delay, -40 to 158 F; delay range and coil not listedTime delay for listed Carrier models

A potential relay is normally closed. The voltage generated by the motor in its start winding opens the contacts at about 75 percent of motor speed, which removes the start capacitor, and the relay closes again when the motor stops. Browse fan relays, potential relays, and time delay relays.

Disconnect switches

For air conditioning equipment, the National Electrical Code calls for the disconnecting means to be within sight of and readily accessible from the equipment, where within sight means visible and not more than 50 feet away. Our guide to choosing an AC disconnect box covers fusible and non-fusible types.

DisconnectKey specs from the listingNotes
DiversiTech DG322URB60A, 3-pole, 240V, non-fused, NEMA 3R, UL 98Rainproof steel enclosure
ABB OT200U03200A, 3-pole, DIN rail mounted, UL 98, 170 x 170 x 70 mmVoltage and enclosure not listed
Lennox 78W55150A, 3-pole, 600VListed for Lennox models such as KCA092H4-1 and KGA300S4-1

Match the amp rating, poles, voltage, and enclosure to the equipment, and use a weatherproof enclosure outdoors. Have a licensed electrician install disconnects. Browse disconnect switches.

Overload relays and motor starters

An overload relay protects a motor by cutting power when current stays too high. Trip class sets how fast it reacts. According to Schneider Electric, at 600 percent of the rated thermal current a class 10 relay trips in 10 seconds or less, class 20 in 20 seconds or less, and class 30 in 30 seconds or less. Our guide to the top uses for overload relays in HVAC and motor protection covers types and selection.

PartKey specs from the listingNotes
Schneider Electric LR2D3555Thermal overload relay, 30 to 40 A, class 20, phase unbalance protection, screw clamp terminalsMounts directly on TeSys D contactors
Eaton AN16KN0ANon-reversing starter, C306 bimetal overload relay, NEMA size 3 open, 90 A, 25 hp, 3-pole, 120/60 or 110/50 coilFull-voltage motor starter

Match the relay to the motor's voltage, current, and starting characteristics, and to the contactor it mounts on. Browse overload relays.

Current, flow, limit, and float switches

SwitchKey specs from the listingUse
Functional Devices RIBX24BF24 Vac/dc coil, 20 A SPDT relay, solid-state sensor contact 30 Vac/dc at 0.4 A, NEMA 1, UL ListedCurrent switch with relay
Veris H-938Split core, adjustable 2.5 to 135 A, relay output 10 A at 240 VAC, 24 to 240 VAC/DC operation, NEMA 1Motor monitoring
McDonnell & Miller FS2511 inch NPT, adjustable flow setting, NEMA 1, IP54Liquid flow proving
Honeywell BZE6-2RQEnclosed limit switch, top plunger, SPDT snap action, 600 VAC / 250 VDC, 22 A, 1/2-14 NPT conduitIndustrial position limit
Honeywell L4064B2228Fan and limit control, 5 inch insert, manual fan switch, -40 to 190 FForced-air furnace fan and limit
Liberty Pumps K001054115V float switch, 10 foot cordAutomatic submersible pump control

A current switch detects current flow, a flow switch proves liquid or air movement, and a limit switch acts at a temperature or position. Our guide to limit switches in HVAC, industrial, and home use explains furnace limit and fan limit switches. Browse current switches, flow switches, and limit switches.

Transfer switches

A transfer switch moves a load between two power sources, such as the utility and a generator, and it prevents the generator from feeding power back into the utility line. An open transition switch breaks contact with one source before it makes contact with the other.

Transfer switchKey specs from the listingNotes
Honeywell RXSM200A3200 A, 120/240V single phase, open transition, NEMA 3R, 22,000 A withstand ratingAutomatic transfer switch
Generac RXGW20SHA3200 A, 20 circuit load center, 120/240V, open transition, NEMA 3RWorks with Generac Evolution and Nexus controllers; ships LTL

Have a licensed electrician install transfer switches and confirm local code and utility requirements.

Before you order: things to check

  • Match the coil voltage before anything else on a relay
  • Check the contact configuration (SPST, SPDT, DPDT) and the contact current rating
  • Match the amp rating, poles, voltage, and enclosure on a disconnect
  • Match the overload relay current range and trip class to the motor
  • Confirm the fit or model, since some listings name only certain equipment
  • Check the title, the specifications, and the description together, since ratings can differ between them
  • Disconnect and verify power is off before replacing any switch or relay
  • Hire a licensed electrician for disconnect, panel, and transfer switch work
  • Read the explanation in our safety switches guide

Switches & relays glossary

SPDT
Single pole, double throw, a contact arrangement with one common terminal that switches between a normally open and a normally closed contact. Shop switching relays →
Trip class
The rating that tells how fast an overload relay trips under a heavy overload; class 10 trips in 10 seconds or less at 6 times its rated current, class 20 in 20 seconds or less. Shop overload relays →
Potential relay
A normally closed relay that drops the start capacitor out of a compressor circuit once the motor reaches speed. Shop potential relays →
Split-core current switch
A current switch that clamps around an existing conductor, so the wire does not have to be disconnected for installation. Shop current switches →
Non-fused disconnect
A switch that cuts power to equipment without containing fuses, relying on an overcurrent device elsewhere. Shop disconnect switches →
Open transition
A transfer switch design that breaks contact with one power source before it makes contact with the other. Shop switching relays →
Limit switch
A switch that opens or closes at a set temperature or position, such as a furnace limit that shuts the unit down to prevent overheating. Shop limit switches →

Frequently asked questions

What switches and relays does Voomi Supply carry?

The range covers ten areas: current switches, disconnect switches, overload relays, rollout switches, flow switches, limit switches, fan relays, potential relays, switching relays, and time delay relays. Brand collections add parts from Honeywell, Eaton, ABB, Schneider Electric, White-Rodgers, McDonnell & Miller, and others. Browse the full switches and relays collection or search by part number.

What is the difference between a relay, a contactor, and an overload relay?

A relay uses a low-power signal to switch a small or control circuit, and our technician guide describes relays as handling currents up to about 10 amps. A contactor switches heavy loads such as motors and compressors, typically at 9 amps and above. An overload relay does not switch the load on demand. It protects a motor by cutting power when current stays too high for too long. The Schneider LR2D3555 is an example of an overload relay, and the IDEC RH4B-UAC24V is an example of a 4PDT control relay.

What is the difference between a current switch and a relay?

A current switch detects current flowing in a conductor and gives a signal, which is why it is often used to prove that a motor or fan is running. A relay uses a low-power signal to switch a higher-power circuit. Some products combine both, such as the Functional Devices RIBX24BF, which pairs a current switch with a 20 amp SPDT relay. Split-core models like the Veris H-938 clamp around an existing conductor without disconnecting it, while fixed-core models require the conductor to be disconnected. See current switches for the full range.

What does a potential relay do, and how do I choose one?

A potential relay takes the start capacitor out of a compressor motor circuit once the motor is up to speed. The relay is normally closed, and the voltage generated by the motor in the start winding opens the contacts at about 75 percent of motor speed. It drops out and closes again when the motor stops. Match the coil voltage, pickup and dropout voltages, and contact rating to the original. The Mars 19163, for example, lists a 170 VAC continuous coil, 140 to 153 VAC pickup, and 30 to 65 VAC dropout. Browse potential relays for more.

How do I choose a fan relay?

Match the coil voltage, which is commonly 24V, 110/120V, or 208/240V, then the contact configuration (SPST or SPDT) and the contact current rating. For example, the White-Rodgers 90-294Q has a 115/120 VAC coil with SPDT contacts, while the Trane RLY1963 is a 24V relay rated 6 amps with a 60 second on and 120 second off timing. The White-Rodgers listing shows more than one contact rating, so confirm it against the manufacturer sheet. Disconnect power before replacing any relay.

What does a time delay relay do?

An on-delay relay starts the connected equipment only after a set delay following a control signal, and an off-delay relay keeps equipment running for a set time after the signal ends. In HVAC, delays are used for fan start timing and compressor delays, and their main job is preventing short cycling. The Mars 32391 offers an adjustable delay from 0.1 to 8 minutes at 240 VAC. Check the delay range and the coil voltage on the listing, because some listings do not state them.

What does overload relay trip class mean?

Trip class tells you how quickly the relay trips under a heavy overload. According to Schneider Electric, at 600 percent (6 times) of the rated thermal current, a class 10 relay trips in 10 seconds or less, class 20 in 20 seconds or less, and class 30 in 30 seconds or less. The Schneider LR2D3555 is a class 20 relay with a 30 to 40 amp setting range. Choose the class that suits the motor's starting characteristics, and see overload relays for the available ranges.

What is the difference between fusible and non-fused disconnect switches, and where do they go?

A fused disconnect holds fuses for overcurrent protection, while a non-fused disconnect relies on a separate device such as a circuit breaker. For air conditioning equipment, the National Electrical Code calls for the disconnecting means to be within sight of and readily accessible from the equipment, and within sight means visible and not more than 50 feet away. Match the amp rating, poles, voltage, and enclosure. The DiversiTech DG322URB is a 60 amp, 3-pole, 240 volt non-fused switch in a NEMA 3R enclosure.

How does a flow switch work, and which type do I need?

A paddle flow switch uses a mechanical paddle in the pipe to detect liquid flow, while electronic models use non-mechanical sensors. Choose by fluid, pipe size, flow rate, pressure rating, and reset type. The McDonnell & Miller FS251 is a general purpose flow switch with a 1 inch NPT connection and an adjustable flow setting. Flow switches are commonly used to protect pumps, fans, and heating or cooling coils, so confirm fit with your equipment before ordering. See flow switches for other models.

What is a transfer switch, and what does open transition mean?

A transfer switch moves a load between two power sources, such as the utility and a generator, and it prevents the generator from feeding power back into the utility line. An open transition switch is a break-before-make design, meaning it breaks contact with one source before it makes contact with the other. The Honeywell RXSM200A3 and the Generac RXGW20SHA3 are both listed as 200 amp, 120/240 volt, open transition automatic transfer switches in NEMA 3R enclosures. Have a licensed electrician install them and check local code.

Read more

Visit the blog →

Keep shopping