Switches & Relays: Disconnects, Overload, Fan, Potential & Time Delay Relays
Voomi Supply carries switches and relays for HVAC equipment, motor control, and building systems, including current switches, disconnect switches, overload relays, rollout switches, flow switches, limit switches, fan relays, potential relays, switching relays, and time delay relays. Browse by part type or by brand, including Honeywell, Eaton, ABB, and White-Rodgers. Switches and relays are matched by voltage, current rating, and configuration, so check the specs on each listing.
Shop by category
View all switches & relays →Popular switches & relays
Shop all switches & relays →Brands we carry
Which switch or relay do I need?
Most orders start with a job: prove a motor is running, isolate equipment for service, protect a motor, or start and stop a fan or compressor. Match the job to the device type, then check voltage, current, and contact configuration on the listing.
| What you need to do | Product | Shop |
|---|---|---|
| Prove current is flowing in a motor or fan circuit | Current switch | Current switches |
| Isolate equipment for service | Disconnect switch | Disconnect switches |
| Protect a motor from overload | Overload relay | Overload relays |
| Shut off a furnace if flame rolls out | Rollout switch | Rollout switches |
| Prove water or air is flowing | Flow switch | Flow switches |
| Open or close at a set temperature or position | Limit switch | Limit switches |
| Start and stop a blower or fan | Fan relay | Fan relays |
| Drop out a compressor start capacitor | Potential relay | Potential relays |
| Switch a load from a control signal | Switching relay | Switching relays |
| Delay a start or prevent short cycling | Time delay relay | Time delay relays |
Relays: fan, potential, and time delay
Relays handle control signals and smaller loads, while contactors carry heavier ones. Our guide to the difference between a relay and a contactor gives about 10 amps as the usual relay limit. Match the coil voltage first, then the contacts.
| Relay | Key specs from the listing | Use |
|---|---|---|
| White-Rodgers 90-294Q | 115/120 VAC coil, 2,000 ohm coil resistance, SPDT; contact rating varies on the listing | Fan relay |
| Trane RLY1963 | 24V, 6A, 60 second on and 120 second off timing | Cycling fan relay |
| Mars 19163 | 170 VAC continuous coil, 140 to 153 VAC pickup, 30 to 65 VAC dropout, 3.5 A, 1/4 inch quick connect | Potential relay for compressor starting |
| Copeland 940-0001-62 | Potential relay kit, up to 115V | Replacement for relays in light commercial refrigerant units |
| IDEC RH4B-UAC24V | 4PDT, 24VAC coil, plug-in; contact rating not listed | Control circuits |
| Mars 32391 | 240 VAC, 50/60 Hz, 0.1 to 8 minute adjustable delay | Time delay |
| Carrier HK61EA009 | Solid-state, adjustable delay, -40 to 158 F; delay range and coil not listed | Time delay for listed Carrier models |
A potential relay is normally closed. The voltage generated by the motor in its start winding opens the contacts at about 75 percent of motor speed, which removes the start capacitor, and the relay closes again when the motor stops. Browse fan relays, potential relays, and time delay relays.
Disconnect switches
For air conditioning equipment, the National Electrical Code calls for the disconnecting means to be within sight of and readily accessible from the equipment, where within sight means visible and not more than 50 feet away. Our guide to choosing an AC disconnect box covers fusible and non-fusible types.
| Disconnect | Key specs from the listing | Notes |
|---|---|---|
| DiversiTech DG322URB | 60A, 3-pole, 240V, non-fused, NEMA 3R, UL 98 | Rainproof steel enclosure |
| ABB OT200U03 | 200A, 3-pole, DIN rail mounted, UL 98, 170 x 170 x 70 mm | Voltage and enclosure not listed |
| Lennox 78W55 | 150A, 3-pole, 600V | Listed for Lennox models such as KCA092H4-1 and KGA300S4-1 |
Match the amp rating, poles, voltage, and enclosure to the equipment, and use a weatherproof enclosure outdoors. Have a licensed electrician install disconnects. Browse disconnect switches.
Overload relays and motor starters
An overload relay protects a motor by cutting power when current stays too high. Trip class sets how fast it reacts. According to Schneider Electric, at 600 percent of the rated thermal current a class 10 relay trips in 10 seconds or less, class 20 in 20 seconds or less, and class 30 in 30 seconds or less. Our guide to the top uses for overload relays in HVAC and motor protection covers types and selection.
| Part | Key specs from the listing | Notes |
|---|---|---|
| Schneider Electric LR2D3555 | Thermal overload relay, 30 to 40 A, class 20, phase unbalance protection, screw clamp terminals | Mounts directly on TeSys D contactors |
| Eaton AN16KN0A | Non-reversing starter, C306 bimetal overload relay, NEMA size 3 open, 90 A, 25 hp, 3-pole, 120/60 or 110/50 coil | Full-voltage motor starter |
Match the relay to the motor's voltage, current, and starting characteristics, and to the contactor it mounts on. Browse overload relays.
Current, flow, limit, and float switches
| Switch | Key specs from the listing | Use |
|---|---|---|
| Functional Devices RIBX24BF | 24 Vac/dc coil, 20 A SPDT relay, solid-state sensor contact 30 Vac/dc at 0.4 A, NEMA 1, UL Listed | Current switch with relay |
| Veris H-938 | Split core, adjustable 2.5 to 135 A, relay output 10 A at 240 VAC, 24 to 240 VAC/DC operation, NEMA 1 | Motor monitoring |
| McDonnell & Miller FS251 | 1 inch NPT, adjustable flow setting, NEMA 1, IP54 | Liquid flow proving |
| Honeywell BZE6-2RQ | Enclosed limit switch, top plunger, SPDT snap action, 600 VAC / 250 VDC, 22 A, 1/2-14 NPT conduit | Industrial position limit |
| Honeywell L4064B2228 | Fan and limit control, 5 inch insert, manual fan switch, -40 to 190 F | Forced-air furnace fan and limit |
| Liberty Pumps K001054 | 115V float switch, 10 foot cord | Automatic submersible pump control |
A current switch detects current flow, a flow switch proves liquid or air movement, and a limit switch acts at a temperature or position. Our guide to limit switches in HVAC, industrial, and home use explains furnace limit and fan limit switches. Browse current switches, flow switches, and limit switches.
Transfer switches
A transfer switch moves a load between two power sources, such as the utility and a generator, and it prevents the generator from feeding power back into the utility line. An open transition switch breaks contact with one source before it makes contact with the other.
| Transfer switch | Key specs from the listing | Notes |
|---|---|---|
| Honeywell RXSM200A3 | 200 A, 120/240V single phase, open transition, NEMA 3R, 22,000 A withstand rating | Automatic transfer switch |
| Generac RXGW20SHA3 | 200 A, 20 circuit load center, 120/240V, open transition, NEMA 3R | Works with Generac Evolution and Nexus controllers; ships LTL |
Have a licensed electrician install transfer switches and confirm local code and utility requirements.
Before you order: things to check
- Match the coil voltage before anything else on a relay
- Check the contact configuration (SPST, SPDT, DPDT) and the contact current rating
- Match the amp rating, poles, voltage, and enclosure on a disconnect
- Match the overload relay current range and trip class to the motor
- Confirm the fit or model, since some listings name only certain equipment
- Check the title, the specifications, and the description together, since ratings can differ between them
- Disconnect and verify power is off before replacing any switch or relay
- Hire a licensed electrician for disconnect, panel, and transfer switch work
- Read the explanation in our safety switches guide
Switches & relays glossary
- SPDT
- Single pole, double throw, a contact arrangement with one common terminal that switches between a normally open and a normally closed contact. Shop switching relays →
- Trip class
- The rating that tells how fast an overload relay trips under a heavy overload; class 10 trips in 10 seconds or less at 6 times its rated current, class 20 in 20 seconds or less. Shop overload relays →
- Potential relay
- A normally closed relay that drops the start capacitor out of a compressor circuit once the motor reaches speed. Shop potential relays →
- Split-core current switch
- A current switch that clamps around an existing conductor, so the wire does not have to be disconnected for installation. Shop current switches →
- Non-fused disconnect
- A switch that cuts power to equipment without containing fuses, relying on an overcurrent device elsewhere. Shop disconnect switches →
- Open transition
- A transfer switch design that breaks contact with one power source before it makes contact with the other. Shop switching relays →
- Limit switch
- A switch that opens or closes at a set temperature or position, such as a furnace limit that shuts the unit down to prevent overheating. Shop limit switches →
Frequently asked questions
What switches and relays does Voomi Supply carry?
The range covers ten areas: current switches, disconnect switches, overload relays, rollout switches, flow switches, limit switches, fan relays, potential relays, switching relays, and time delay relays. Brand collections add parts from Honeywell, Eaton, ABB, Schneider Electric, White-Rodgers, McDonnell & Miller, and others. Browse the full switches and relays collection or search by part number.
What is the difference between a relay, a contactor, and an overload relay?
A relay uses a low-power signal to switch a small or control circuit, and our technician guide describes relays as handling currents up to about 10 amps. A contactor switches heavy loads such as motors and compressors, typically at 9 amps and above. An overload relay does not switch the load on demand. It protects a motor by cutting power when current stays too high for too long. The Schneider LR2D3555 is an example of an overload relay, and the IDEC RH4B-UAC24V is an example of a 4PDT control relay.
What is the difference between a current switch and a relay?
A current switch detects current flowing in a conductor and gives a signal, which is why it is often used to prove that a motor or fan is running. A relay uses a low-power signal to switch a higher-power circuit. Some products combine both, such as the Functional Devices RIBX24BF, which pairs a current switch with a 20 amp SPDT relay. Split-core models like the Veris H-938 clamp around an existing conductor without disconnecting it, while fixed-core models require the conductor to be disconnected. See current switches for the full range.
What does a potential relay do, and how do I choose one?
A potential relay takes the start capacitor out of a compressor motor circuit once the motor is up to speed. The relay is normally closed, and the voltage generated by the motor in the start winding opens the contacts at about 75 percent of motor speed. It drops out and closes again when the motor stops. Match the coil voltage, pickup and dropout voltages, and contact rating to the original. The Mars 19163, for example, lists a 170 VAC continuous coil, 140 to 153 VAC pickup, and 30 to 65 VAC dropout. Browse potential relays for more.
How do I choose a fan relay?
Match the coil voltage, which is commonly 24V, 110/120V, or 208/240V, then the contact configuration (SPST or SPDT) and the contact current rating. For example, the White-Rodgers 90-294Q has a 115/120 VAC coil with SPDT contacts, while the Trane RLY1963 is a 24V relay rated 6 amps with a 60 second on and 120 second off timing. The White-Rodgers listing shows more than one contact rating, so confirm it against the manufacturer sheet. Disconnect power before replacing any relay.
What does a time delay relay do?
An on-delay relay starts the connected equipment only after a set delay following a control signal, and an off-delay relay keeps equipment running for a set time after the signal ends. In HVAC, delays are used for fan start timing and compressor delays, and their main job is preventing short cycling. The Mars 32391 offers an adjustable delay from 0.1 to 8 minutes at 240 VAC. Check the delay range and the coil voltage on the listing, because some listings do not state them.
What does overload relay trip class mean?
Trip class tells you how quickly the relay trips under a heavy overload. According to Schneider Electric, at 600 percent (6 times) of the rated thermal current, a class 10 relay trips in 10 seconds or less, class 20 in 20 seconds or less, and class 30 in 30 seconds or less. The Schneider LR2D3555 is a class 20 relay with a 30 to 40 amp setting range. Choose the class that suits the motor's starting characteristics, and see overload relays for the available ranges.
What is the difference between fusible and non-fused disconnect switches, and where do they go?
A fused disconnect holds fuses for overcurrent protection, while a non-fused disconnect relies on a separate device such as a circuit breaker. For air conditioning equipment, the National Electrical Code calls for the disconnecting means to be within sight of and readily accessible from the equipment, and within sight means visible and not more than 50 feet away. Match the amp rating, poles, voltage, and enclosure. The DiversiTech DG322URB is a 60 amp, 3-pole, 240 volt non-fused switch in a NEMA 3R enclosure.
How does a flow switch work, and which type do I need?
A paddle flow switch uses a mechanical paddle in the pipe to detect liquid flow, while electronic models use non-mechanical sensors. Choose by fluid, pipe size, flow rate, pressure rating, and reset type. The McDonnell & Miller FS251 is a general purpose flow switch with a 1 inch NPT connection and an adjustable flow setting. Flow switches are commonly used to protect pumps, fans, and heating or cooling coils, so confirm fit with your equipment before ordering. See flow switches for other models.
What is a transfer switch, and what does open transition mean?
A transfer switch moves a load between two power sources, such as the utility and a generator, and it prevents the generator from feeding power back into the utility line. An open transition switch is a break-before-make design, meaning it breaks contact with one source before it makes contact with the other. The Honeywell RXSM200A3 and the Generac RXGW20SHA3 are both listed as 200 amp, 120/240 volt, open transition automatic transfer switches in NEMA 3R enclosures. Have a licensed electrician install them and check local code.