Voomi Supply carries plumbing supplies for homeowners, contractors, and plumbers, including water heaters, water heater parts, valves and valve parts, plumbing supplies such as fittings, drains, and insulation, and bathroom and kitchen faucets and hardware. Brands include Rheem, Watts, Bradford White, and Navien. Compare sizes, connections, and ratings on each product page, plus US-based support to help you match the right part to your job.
Most plumbing orders start with a job: heating water, controlling flow, protecting the supply, draining a fixture, or finishing a bathroom or kitchen. Match the job to the category and the exact part follows from the specifications.
| What you need to do | Supply | Shop |
|---|---|---|
| Replace or add a water heater | Storage, tankless, or compact heater | Water heaters |
| Repair a water heater | Burner, valve, thermostat, ignitor, or anode part | Water heater parts |
| Shut off, check, or regulate flow | Ball, gate, check, or pressure reducing valve | Valves & valve parts |
| Protect the water supply | Backflow preventer assembly | Valves & valve parts |
| Connect, seal, or drain piping | Fittings, cements, sealants, drains | Plumbing supplies |
| Protect pipes from cold or condensation | Pipe insulation | Plumbing supplies |
| Update a faucet, shower, or sink | Faucets, shower heads, drains, hardware | Bathroom & kitchen |
Water heaters come as conventional storage tanks in gas and electric versions, tankless on-demand systems, heat pump or hybrid units, and specialty options such as solar, condensing, and immersion models. Storage heaters are sized by first hour rating, the maximum gallons of hot water the unit can supply in an hour when fully heated, so compare it with your household's busiest hour rather than tank size alone. A compact unit suits a different job: the Bradford White RE1-2U6-1NAL holds 2 gallons, draws 1.5 kW at 120 VAC, and is listed for locations with low hot water demand or a long distance from the main heater, such as an under-sink or wash station. Tank heaters last 10 to 15 years according to our water heater guide, versus 20 or more for tankless. Compare the full range of water heaters by fuel, capacity, and type.
| Part | What it does |
|---|---|
| Burners and pilot assemblies | Burn gas to heat the water on gas models; pilot parts keep the flame lit |
| Ignitors and ignition switches | Light the burner on models with electronic ignition |
| Flame scanners and retainers | Detect the flame so the control can shut off gas if it goes out |
| Gas control thermostats and gas valves | Regulate temperature and the flow of gas to the burner |
| Thermostats and aquastats | Set and hold water temperature on electric and hydronic heaters |
| T&P relief valve and discharge tube | Safely release excess temperature or pressure; required on storage heaters |
| Anode rod | Corrodes in place of the tank; replace every 3 to 5 years, or more often in soft water |
| Fan and motor vent assemblies | Move combustion air and exhaust on power vent models, such as the Rheem AP10983-4 for 40 and 50 gallon heaters |
Electric heater components are often user-replaceable, while gas valves, pilot assemblies, dip tubes, expansion tanks, and gas burners may require professional installation because of plumbing and safety codes. Find the full range in water heater parts, and read our guide to gas control thermostats for how the control and gas valve work together.
Two parts often show up together on the same water line. A reduced pressure zone backflow preventer protects the supply: it has two check valves in one body with a relief valve between them, and the relief valve discharges to the atmosphere if the pressure in the central chamber nears the inlet pressure. These assemblies are used on high hazard connections, the relief port must never be plugged, and testing and installation follow local rules. The Watts 1LF009M2-QT-FS is a 1 inch lead-free assembly with quarter-turn shutoff valves, and the Wilkins 975XL2-1 is a 1 inch wye-pattern bronze assembly with independent access to the check valves and relief valve. A backflow preventer also closes the system, so heated water can no longer push back into the main. The Uniform Plumbing Code calls for an approved, listed, adequately sized expansion tank on a water system that has such a device. Use the right kind of tank: a potable tank for domestic water, and a hydronic tank such as the Flexcon HTX15, listed at 2.1 gallons, 100 psi, and 240 F, for heating loops only.
| Valve type | Best use |
|---|---|
| Ball valve | Quarter-turn shutoff with a tight seal; standard in modern residential and commercial plumbing |
| Gate valve | Full flow when open and slower to operate; suited to valves left open or closed for long periods |
| Globe valve | Throttling and managing flow rates |
| Check valve | Allows flow in one direction only to prevent backflow |
| Pressure reducing valve | Lowers and manages water pressure in the system |
| Thermostatic mixing valve | Mixes hot and cold water for safer showers |
| Butterfly and diaphragm valves | Compact valves used in HVAC and similar systems |
Match the valve to the pipe diameter and choose a connection style that suits the job, such as threaded, soldered, flanged, or push-fit. Valves come in brass, stainless steel, PVC or CPVC, and cast iron. Our guide on gate valves versus ball valves compares the two in detail, and common valve issues and how to rebuild them covers leaks, sticking, and packing failure.
Pipe material depends on the system. According to our PVC versus CPVC guide, PVC is rated for water up to 140 F and suits cold water and drains, while CPVC withstands up to 200 F for hot water, and PVC can degrade in direct sunlight without protection. For drains, the Jones Stephens C60170 is a 4 inch PVC clean-out with a 4-1/2 inch nickel bronze cover designed for post-pour concrete installation, the Wingtite SD1000-043 is a 2 inch PVC shower drain that installs entirely from the top, and the Jay R. Smith 2010X is a cast iron adapter that raises a strainer head to meet deeper floor fills. For cold climates our insulation guide recommends R-4 or higher, with elastomeric foam, fiberglass, and foil-backed wraps as the main materials. Browse plumbing supplies for fittings, cements, sealants, and insulation.
For faucets, start with the sink and the mounting holes. A vessel sink needs a tall or wall-mounted faucet, while undermount and integrated sinks suit deck-mounted or single-hole styles, and finish and hole configuration matter as much as looks. The Moen 7565ESRS Align is a one-handle, high-arc pull-down kitchen faucet with MotionSense hands-free operation, a 1.5 GPM flow rate at 60 PSI, and a lead-free Spot Resist Stainless finish, listed to NSF 61 among other standards. If a faucet only needs a repair, a model-specific part such as the Kohler 1176882-CP spray head is sold for the Simplice K-596, K-597, K-647, K-649, and K-R648. Our guide to matching bathroom faucets with modern sink styles covers sink types and finishes, and the full range is in bathroom and kitchen.
The plumbing range covers five areas: water heaters, water heater parts, valves and valve parts, general plumbing supplies, and bathroom and kitchen products. General supplies include adhesives and cements, caulks and sealants, drain cleaners, drains and sinks, galvanized piping, pipe cutters and threading tools, pipe fittings, and pipe insulation, while bathroom and kitchen covers faucets, shower heads, vanities, toilets, tubs, and hardware. Browse the full range of plumbing supplies or contact us if you need help finding a part.
Tank water heaters are sized by first hour rating, which ENERGY STAR defines as an estimate of the maximum volume of hot water, in gallons, that a storage water heater can supply within an hour when fully heated. Compare that rating with your household's peak hour of use, such as several showers plus a dishwasher. As a starting point, our water heater guide suggests 30 to 40 gallons for 1 to 2 people, 40 to 50 gallons for 3 to 4 people, and 50 to 80 gallons for 5 or more. Check the space, fuel type, and venting as well, and compare options in water heaters.
Our guide recommends flushing the tank annually, or every 6 months in hard water areas, and replacing the anode rod every 3 to 5 years, or more often in soft water. Every storage water heater also needs a combination temperature and pressure relief valve, so check that it is in place and the discharge tube is clear. Gas valves, pilot assemblies, dip tubes, expansion tanks, and gas burners can require professional installation because of plumbing and safety codes, so call a licensed plumber when in doubt.
You need one when the water system is closed, which means a check valve, pressure reducing valve, or backflow preventer stops expanding hot water from flowing back into the main. The Uniform Plumbing Code requires an approved, listed, adequately sized expansion tank on a water system with such a device. Water expands about 2 percent when heated from 50 to 120 degrees F, and in a closed system that expansion raises pressure in the tank, piping, and fixtures. Potable and hydronic tanks are not interchangeable: the Flexcon HTX15, for example, is listed for hydronic heating systems, not for drinking water. Match the tank pre-charge to your static supply pressure.
A reduced pressure zone assembly has two check valves in one body with a relief valve between them, and it keeps the pressure in the central chamber lower than the incoming supply. If a check valve fails, the relief valve discharges to the atmosphere instead of letting contaminated water flow back into the supply. These assemblies are used on high hazard connections, and the relief port must never be plugged. They are tested in the field with a differential pressure gauge, and testing and installation rules vary by local authority, so confirm what your water provider requires. See valves and valve parts for assemblies such as the Watts 1LF009M2-QT-FS and Wilkins 975XL2.
Ball valves use a quarter-turn handle, seal tightly, and are standard in modern residential and commercial plumbing. Gate valves use a wedge-shaped gate raised and lowered by a handwheel, which is slower to operate, and our guide notes they suit valves that stay open or closed for long periods and can leak over time. Ball valves cost more at first, but the guide calls them the better long-term investment for most systems. Match the valve size, material, and connection style, such as threaded, soldered, flanged, or push-fit, to your pipe.
Under the Safe Drinking Water Act, EPA defines lead-free for pipes, fittings, and fixtures as a weighted average of no more than 0.25 percent lead across the wetted surfaces, and 0.2 percent for solder and flux. Look for lead-free statements and certifications on the listing, such as the NSF 61 listing on the Moen 7565ESRS faucet. Products meant only for non-potable uses, such as hydronic heating, are not made for drinking water. Browse bathroom and kitchen faucets and fixtures for lead-free faucets and hardware.
Select in-stock items ship the same day when ordered by 12 pm, and some listings offer same-day delivery in the Greater Chicago area for orders placed before 4 pm CT, Monday to Friday. For bathroom and kitchen products, unused items may be returned within 30 days in original packaging, and some returns may carry a restocking fee. Terms differ by listing, so check the product page before ordering and contact us with the model number if you are unsure about a fit.