Pool Heaters & Accessories: Flow-Thru Heaters, Elements, Hi-Limits & Thermostats

Voomi Supply carries pool and spa heaters and heater parts for repairs, replacements, and upgrades, including pool flow thru heaters, low flow heaters, pool heater elements, pool hi limit sensors, pool thermostats, and pool heater unions. Browse by part type or by brand, including Raypak, Coates Heater, HydroQuip, and Balboa Water Group. Heater parts are matched to specific models, so check the voltage, wattage, and fit on each listing.

Why buy from Voomidatasheet
CategoriesHeaters, elements, hi-limits, thermostats & unions
HeatersFlow-thru and low flow, pool and spa
PartsElements, sensors, controls & flame sense rods
BrandsRaypak, Coates Heater & more
ShippingSame-day on select items ordered by 12 pm
Find your heater part or model number
Same-DayDispatch on select items ordered by 12 pm
6 CategoriesHeaters to thermostats
Name BrandsRaypak, Coates, HydroQuip, Balboa and more
Spec DetailsPower, voltage and fit on listings
US SupportPhone, chat and email help

Popular pool heaters & accessories

Shop all pool heaters & accessories →

Brands we carry

Which pool heater product do I need?

Most heater orders start with a symptom or a project: no heat, a tripped limit, a worn element, or a replacement spa heater. Match the job to the part type, then check power, voltage, and fit on the listing.

What you need to doProductShop
Replace a spa or small-pool electric heaterFlow-thru heaterPool flow thru heaters
Heat a spa or above-ground pool with reduced circulationLow flow heaterLow flow heaters
Restore heat after an element wears outHeater elementPool heater elements
Fix repeated high limit faults or replace a cutoffHi-limit sensorPool hi limit sensors
Control the water temperature setpointThermostat or temperature sensorPool thermostats
Reconnect a heater to the plumbingHeater unionPool heater unions

Heater power: kW, BTU, and sizing

Electric heaters are rated in kilowatts, while gas heaters are rated in BTU. One kilowatt-hour equals about 3,412 BTU, so each kW of electric heat is about 3,412 BTU per hour. The U.S. Department of Energy gives a basic sizing method: multiply the pool surface area in square feet by the temperature rise you want in degrees Fahrenheit and by 12 to estimate the BTU per hour needed, and it recommends a sizing analysis from a trained pool professional.

Heater or elementPowerApprox. BTU per hourNotes
Balboa G7412-014.0 kW13,650Flow-thru heater for BP Series systems
HydroQuip 48-PS40-B4 kW13,650Flow-thru heater for Platinum B systems
HydroQuip 27-V310-7T-K5.5 kW18,770Vertical low flow canister heater
Coates 2000600415 kW51,180Replacement element, not a complete heater

For example, a 15 x 30 foot pool is 450 square feet, and raising it by 10 degrees needs about 54,000 BTU per hour, or roughly 15.8 kW of electric resistance heat. That is why the 4 kW and 5.5 kW heaters above are intended for spas and small volumes rather than a full-size pool.

Spa and flow-thru heaters

HeaterKey specs from the listingNotes
Balboa G7412-014.0 kW, 230V, 2 inch inlet and outlet, 15 inch length, straight housing, Plug-n-Click connectorBP Series; replaces 26-G7412-K and 388670
HydroQuip 48-PS40-B4 kW, 15 x 2 inch tube, 60 inch cord, two Balboa M7 sensorsFor HydroQuip Platinum B control systems; confirm voltage on the listing
HydroQuip 27-V310-7T-K5.5 kW, vertical low flow canister, titanium element, manual-reset hi-limit, heater-on indicator lightUniversal replacement; confirm fit and voltage

Browse pool flow thru heaters and low flow heaters.

Heater elements

An element is a wear part, so match it exactly. Voltage, wattage, flange or fitting type, length, and model number must all agree with the original.

ElementKey specs from the listingListed fit
Coates 2000600415 kW, 208V, 4-bolt flange, gasket includedCoates CPH and PHS heaters
Raypak 001801F5.5 kW, 240V, 3 x 3 inch flange with four holes, welded, flying wire leads, gasket includedRaypak heating systems; confirm model

Before ordering, compare the listing with the label on your heater, since models and voltages vary. Browse pool heater elements.

Hi-limits, thermostats, and control parts

PartKey specs from the listingListed fit
Pentair 471694 Hi-Limit150 F, 1/4 inch NPT thread, threads into the top of the main headerMiniMax NT and CH heaters
Raypak 011585F ThermostatSolid state thermostatRaypak Versa 106A and 130A DSI heaters
Zodiac R0387000 Flame Sense RodDetects flame so the heater operates safelyJandy LX and LT Low NOx heaters, models 250 and 400
Pentair FPSAUX Freeze SensorFreeze protection sensorCompool CP30 and CP100 controllers and auxiliary pumps

Browse pool hi limit sensors and pool thermostats by heater brand and model.

Electric, gas, and heat pump heating

The heater type sets the parts you need. Our guide to the best pool heaters for every climate and pool type compares gas heaters and heat pumps, with models up to 406,000 BTU.

TypeHow it heatsWhat to know
Electric resistanceAn element heats the water as it flows past; about 3,412 BTU per hour per kWCommon in spa packs and small volumes, sized in kW
Gas or propaneA burner heats the water, rated in BTUParts include flame sense rods, hi-limits, and thermostats matched to the model
Heat pumpMoves heat from outside air to the pool waterDOE lists COP of 3.0 to 7.0, efficient above about 45 to 50 F air temperature

Match replacement parts to the heater type and model, and have gas, wiring, and venting work done by a qualified professional.

Before you order: things to check

  • Find the heater model and the part number on the data label
  • Match voltage, wattage, flange or fitting type, and length on elements
  • Match the temperature rating and mounting on hi-limits
  • Confirm the listed fit, since some listings name only certain models
  • Check the title, the specifications, and the description together, since voltage and model details can differ between them
  • Size the heater to the pool volume and the temperature rise you want
  • Confirm unions match your pipe size and end type
  • Turn off power before servicing, and hire a professional for gas or high-voltage work

Pool heater glossary

Flow-thru heater
A heater that warms water as it flows through a tube past the heating element, common in spa packs. Shop pool flow thru heaters →
Low flow heater
A heater built for spas and above-ground pools that run with reduced water circulation. Shop low flow heaters →
Heater element
The part that converts electricity into heat, rated by wattage and voltage and mounted with a flange or fitting. Shop pool heater elements →
Hi-limit
A safety switch or sensor that prevents the heater from overheating. Shop pool hi limit sensors →
Pool thermostat
A control that tells the heater when to turn on or off to hold the temperature setpoint. Shop pool thermostats →
Heater union
A fitting that connects a heater to the plumbing and lets you disconnect it without cutting the pipe. Shop pool heater unions →
BTU
British thermal unit, the unit used to rate heater output; 1 kW of electric heat is about 3,412 BTU per hour. Shop pool heaters & accessories →

Frequently asked questions

What does Voomi Supply carry in pool heaters and accessories?

The range covers six areas: pool flow-thru heaters, low flow heaters, pool heater elements, pool heater unions, pool hi-limit sensors, and pool thermostats. Brand collections add heater parts from Raypak, Coates Heater, HydroQuip, Balboa Water Group, Zodiac, and Pentair. Browse the full pool heaters and accessories collection or search by part number.

How do I size a pool heater?

The U.S. Department of Energy gives a basic method: multiply the pool surface area in square feet by the temperature rise you want in degrees Fahrenheit, then multiply by 12 to estimate the BTU per hour needed. A 450 square foot pool raised by 10 degrees needs about 54,000 BTU per hour, which is roughly 15.8 kW of electric resistance heat. The DOE also recommends a proper sizing analysis from a trained pool professional, because climate, wind, and pool covers change the result.

How many BTU is a 4 kW or 5.5 kW heater?

One kilowatt-hour equals about 3,412 BTU, so an electric resistance heater puts out about 3,412 BTU per hour for every kW. A 4 kW heater is about 13,650 BTU per hour, a 5.5 kW heater is about 18,770 BTU per hour, and a 15 kW element is about 51,180 BTU per hour. These are the heating outputs only, so check the voltage and the circuit requirements on the listing.

What is the difference between a flow-thru heater and a low flow heater?

Both heat water as it passes through the heater. Flow-thru heaters are compact units common in spa packs, while low flow heaters are built for spas and above-ground pools with reduced circulation. The Balboa G7412-01 is a 4.0 kW flow-thru heater with 2 inch inlet and outlet for BP Series systems, and the HydroQuip 27-V310-7T-K is a 5.5 kW vertical low flow canister heater with a titanium element. Match the type, size, and connections to the heater you are replacing.

How do I choose the right heater element?

Match the voltage, wattage, flange or fitting type, length, and model number of your current element or heater. For example, the Coates 20006004 is a 15 kW, 208 volt element with a 4-bolt flange and gasket for Coates CPH and PHS heaters, while the Raypak 001801F is a 5.5 kW, 240 volt element on a 3 x 3 inch flange with four holes and flying leads. Elements with different voltage, wattage, or terminals are not interchangeable, so confirm fit before you order.

What does a hi-limit do, and which one do I need?

A hi-limit is a safety device that prevents the heater from overheating. Pick one that matches your heater model, its temperature rating, and its mounting. The Pentair 471694 is rated 150 degrees Fahrenheit, threads into the top of the main header with a 1/4 inch NPT thread, and is listed as a replacement for MiniMax NT and CH heaters. Repeated high limit faults are a reason to check water flow before replacing parts.

What is the difference between a pool thermostat, a sensor, and a hi-limit?

A thermostat or temperature sensor tells the heater when to heat to your setpoint, while a hi-limit is a separate safety cutoff for overheating. The Raypak 011585F is a solid state thermostat listed for Raypak Versa 106A and 130A DSI heaters, and the Pentair FPSAUX is a freeze sensor listed for Compool CP30 and CP100 controllers and auxiliary pumps. Replace each part with the type specified for your heater or control.

Are heat pumps more efficient than electric or gas heaters?

According to the U.S. Department of Energy, heat pump pool heaters have a coefficient of performance (COP) of about 3.0 to 7.0, so they deliver 3 to 7 units of heat for every unit of electricity used, and they typically have much lower annual operating costs than gas heaters. They work efficiently as long as the outside air temperature stays above about 45 to 50 degrees Fahrenheit. Read our guide to heat pumps for inground pools for sizing and care.

Can I use these heaters for a full-size pool as well as a spa?

Check the listing. Many of the complete heaters here, such as the Balboa G7412-01 and the HydroQuip 48-PS40-B, are made for spa and BP or Platinum B control systems and output only about 13,650 BTU per hour at 4 kW. A full-size pool usually needs much more heat, so size the heater to the pool before choosing. Heater elements, hi-limits, and thermostats are matched to the heater model rather than to the pool.

Do I need a heater union?

A union lets you disconnect a heater from the plumbing without cutting or re-gluing pipe, which makes service easier. Match the pipe size, end type, temperature and pressure rating, and gasket style, and replace a leaking or loose union promptly, because it can reduce flow, let in air, and trigger low-flow shutoffs. Browse pool heater unions for the sizes in stock.

Read more

Visit the blog →

Keep shopping