Pool Equipment: Pumps, Filters, Motors, Lights, Jets & Safety Gear
Voomi Supply carries pool and spa equipment for repairs, upgrades, and new builds, including pool and spa pumps, pool pump motors, pool filters, pool jets, pool lights, pool and spa air blowers, pool and spa flow meters, pool and deck safety gear, and pool toys and accessories. Browse by part type or by brand, including Hayward, Zodiac, Pentair, and Balboa Water Group. Many listings are made for spas or for specific filter and jet models, so check the model and specs on each page.
Shop by category
View all pool equipment →Popular pool equipment
Shop all pool equipment →Brands we carry
Which pool equipment do I need?
Most pool equipment orders start with a job: move water, filter it, light it, or make it safer to enter. Match the job to the product type, then check size, voltage, and fit on the listing.
| What you need to do | Product | Shop |
|---|---|---|
| Circulate water through the filter | Pool or spa pump | Pool & spa pumps |
| Replace a worn pump motor | Pool pump motor | Pool motors |
| Filter out debris and fine particles | Filter, cartridge, or filter part | Pool filters |
| Check how much water is moving | Flow meter | Pool & spa flow meters |
| Add air to spa jets | Air blower | Pool & spa air blowers |
| Replace a jet or jet face | Pool or spa jet | Pool jets |
| Light a pool or spa | Underwater light or retrofit light | Pool lights |
| Make entry and exit safer | Ladder, steps, or deck safety gear | Pool & deck safety |
| Add toys and accessories | Floats, toys, and accessories | Pool toys & accessories |
Pumps and motors: sizing and matching
Pump size starts with flow rate. Many pool pros plan for a full turnover about every 8 hours, and the flow rate in GPM is the pool volume in gallons divided by the turnover time in minutes. Our guide to the best pool pumps for every pool size and budget gives these general horsepower ranges, which are a starting point rather than a rule.
| Pool size | General pump range | Notes |
|---|---|---|
| Small pools and spas, under 10,000 gallons | 0.25 to 1 HP | Compact residential systems and spas |
| Medium pools, 10,000 to 20,000 gallons | 1 to 1.5 HP | Dual-use systems and pools with a pressure-side cleaner may need more |
| Large pools, 20,000 gallons and up | 1.5 to 2 HP or more | Booster pumps for pressure cleaners are typically 0.5 to 1 HP |
When the motor fails but the pump is fine, replace the motor and match its specs. The examples below show the details to compare.
| Pump or motor | Key specs from the listing | Use |
|---|---|---|
| LX Pumps 56WUA400-II (NF) | 4.0 HP, 2-speed, 2 inch suction and discharge, 56 frame thru-bolt | Spa and hot tub pump; replaces the Aqua Flo XP2e |
| Balboa 5235212-S Vico Ultimax | 3.0 HP, 2-speed, 56 frame, side discharge | Spa pump |
| US Motors ASB848 | 1.65 HP, 3450 RPM, 56Y frame, square flange, 115/230V, ODP, 5/8 inch threaded shaft | Pool pump motor |
| Century Q3102 | 1 HP, 3450 RPM, 48Y frame, square flange, three-phase, 208-230/460V | Pool pump motor for three-phase power |
Compare horsepower, frame, voltage, phase, and shaft against your old motor before you order. Browse pool pump motors and pool and spa pumps.
Filters and cartridges
The filter type decides how fine the filtration is and how you maintain it. Our guide to choosing between sand, cartridge, and DE pool filters gives these ranges.
| Filter type | Particles captured | Maintenance |
|---|---|---|
| Sand | About 20 to 40 microns and larger | Backwashed; the sand media is replaced when it wears out |
| Cartridge | About 10 to 20 microns | Cartridge is removed and rinsed, then replaced when worn |
| DE | About 1 to 5 microns | Needs DE powder, plus inspection of the grids |
Replacement parts are model specific. The Zodiac R0554500 is a 7 x 27 inch cartridge with 85 square feet of area each and is listed for a 340 square foot filter, so confirm your filter model and how many cartridges it holds. The Hayward CX200B is a filter head assembly for the C200S SwimClear cartridge filter. A pressure gauge reading 8 to 10 psi above normal is a common sign it is time to clean or service the filter, as covered in our guide on when to replace your pool filter cartridge. Browse pool filters.
Flow meters: choosing a range
A flow meter shows how much water your system is moving, which helps you spot a clogged filter or a failing pump early. Our guide to reading and using a pool flow meter says residential pools typically run about 30 to 50 GPM and suggests checking the meter at least once a month. Pick a meter whose range and pipe size fit your system.
| Flow meter | Key specs from the listing | Typical fit |
|---|---|---|
| H2Flow Controls FV-15 FlowVis | 1.5 inch, CPVC, 50 psi, accuracy listed as 98.1% or better, also acts as a check valve | Pool and spa plumbing |
| Rola-Chem 570371V | 3 inch PVC, vertical mount, 80 to 300 GPM (303 to 1136 LPM) | Higher-flow systems |
Check the range before you buy, because a meter that reads 80 to 300 GPM will not give a useful reading on a low-flow residential line. Browse pool and spa flow meters.
Jets, blowers, and spa parts
| Part | Key specs from the listing | Use |
|---|---|---|
| Balboa 16-5200WHT | Complete Microssage 2-1/2 HS Roto jet, white | Pools and spas |
| Jacuzzi 6541-557 | Intellijet jet face with escutcheon | Spa jet replacement |
| Zodiac JLPBBL | Pebble lid and collar for Jandy JLFBR and JLLED laminar jets | Pool water feature |
| Air Supply 6310241 | 1 HP, 240V, bottom mount, 2 inch fitting, thermally protected | Hot tub and spa air blower |
| Balboa 59303 Ultra Gateway Module RF | Spa control module for ControlMySpa | Spa control upgrade |
Jet parts vary by brand and model, so match the jet series and size to your fitting. Browse pool jets and pool and spa air blowers.
Pool and spa lights
Match the light to the niche, the voltage, and the transformer. Our guide to the best LED pool lights covers fixtures and installation accessories.
| Light | Key specs from the listing | Notes |
|---|---|---|
| Spa Electrics A3 L12 L0 CMP Atom 3 inch | 12W, 10.5 to 13V AC, color changing, IPX8, about 850 lumens, concrete, vinyl, and fiberglass pools | Needs a 12V AC UL-listed transformer |
| Spa Electrics R10H L12 R1 GMP Retro R10 | 45W, 12V AC, color changing, about 3200 lumens, 10 inch niche, universal retrofit | Includes a Hayward 10 inch niche adapter and plug seal kit |
Low-voltage lights run from a transformer, and the National Electrical Code treats 15 volts AC as the low-voltage contact limit. Pool wiring is regulated, so have a licensed electrician install it and check local code. Browse pool lights.
Ladders, steps, and deck safety
| Item | Key specs from the listing | Notes |
|---|---|---|
| S.R.Smith VLLS-104E | 4-step economy ladder, 1.90 inch tubing, Type 304 and 316L stainless steel | Listed as not salt friendly; ships by LTL freight |
| Custom Molded Products 25578-000-000 | Set of 3 pool wall steps, white | Check size and mounting on the listing |
Confirm the entry type, the material, and whether the product suits your water chemistry. Browse pool and deck safety and pool toys and accessories. For floats and games, our guide to pool toys and accessories for families recommends non-toxic, pool-safe materials and always supervising children.
Before you order: things to check
- Check whether the listing is for a pool, a spa, or both
- Match pump and motor horsepower, RPM, frame, voltage, phase, and shaft to the unit you are replacing
- Confirm your filter model and how many cartridges it holds before ordering
- Pick a flow meter whose GPM range and pipe size fit your plumbing
- Check the niche size, voltage, and transformer for pool and spa lights
- Check whether a ladder or rail is listed as salt friendly if you have a saltwater pool
- Check the title, the specifications, and the description together, since model details can differ between them
- Read the setup basics in our essential pool equipment checklist
Pool equipment glossary
- Turnover rate
- The time it takes the pump to circulate the entire volume of the pool through the filter; many residential pools are planned for about 8 hours. Shop pool & spa pumps →
- GPM
- Gallons per minute, the unit used to rate pump output and flow meter range. Shop pool & spa flow meters →
- Frame size
- A standard motor frame designation, such as 48Y or 56Y, that sets the mounting dimensions of the motor. Shop pool pump motors →
- Square flange motor
- A motor with a square mounting face that bolts to the pump housing, common on pool pump replacement motors. Shop pool pump motors →
- Filter area
- The surface area of filter media, measured in square feet, which is listed on cartridges such as the Zodiac R0554500 at 85 square feet each. Shop pool filters →
- Wet niche
- The recess in a pool or spa wall that holds an underwater light fixture. Shop pool lights →
- Laminar jet
- A water feature jet that sends out a smooth, clear arc of water, such as the Jandy JLFBR and JLLED laminar jets. Shop pool jets →
Frequently asked questions
What pool equipment does Voomi Supply carry?
The range covers nine areas: pool and spa air blowers, pool and spa flow meters, pool and spa pumps, pool filters, pool jets, pool lights, pool pump motors, pool and deck safety gear, and pool toys and accessories. Brand collections add parts from Hayward, Zodiac, Pentair, Balboa Water Group, Waterway Plastics, Jacuzzi and others. Browse the full pool equipment collection or search by part number.
How do I size a pool pump?
Start with the flow rate your pool needs. Many pool pros plan for a full turnover about every 8 hours for a residential pool, and the flow rate in GPM is the pool volume in gallons divided by the turnover time in minutes. For a 20,000 gallon pool, 20,000 divided by 480 minutes is about 41.7 GPM. Our pump guide also lists general horsepower ranges by pool volume, from 0.25 to 1 HP for small pools and spas up to 1.5 to 2 HP or more for large pools. Plumbing size, filter size, and any pressure-side cleaner affect the final choice, so treat these numbers as a starting point.
What is the difference between single-speed and two-speed pumps?
A single-speed pump runs at one speed, while a two-speed pump has a high speed for jets, cleaning and heavy circulation and a low speed for everyday filtering. The Waterway 3420610-15 in our pump guide, for example, is listed at 3450 and 1725 RPM. Running the low speed more of the time is the usual reason to choose a two-speed model. Variable-speed pumps let you set the speed more finely.
How do I choose a replacement pool pump motor?
Match the motor to the one you are replacing. Check horsepower, RPM, frame size, voltage, phase, rotation, shaft, and the mounting style. For example, the US Motors ASB848 is a 1.65 HP, 3450 RPM, 56Y frame, square flange pool motor for 115 or 230 volts, with a 5/8 inch threaded shaft and counterclockwise rotation, while the Century Q3102 is a 1 HP, 48Y frame, three-phase motor for 208-230 or 460 volts. A three-phase motor needs a three-phase supply, so confirm your power before ordering.
Should I choose a sand, cartridge, or DE pool filter?
The three types differ in how fine they filter and how they are cleaned. Our filter guide lists sand filters as removing particles larger than about 20 to 40 microns, cartridge filters at about 10 to 20 microns, and DE filters down to about 1 to 5 microns. Sand filters are backwashed, cartridge filters are removed and rinsed, and DE filters need DE powder and grid care. Pick the type that matches your pool, your maintenance habits, and the filter you already own, because replacement cartridges and parts are model specific.
When should I clean or replace a pool filter cartridge?
Look at the signs: weaker flow from the returns, cloudy water, a pressure gauge reading 8 to 10 psi above normal, visible damage, or an old cartridge. Rinsing a cartridge on a regular schedule helps it last longer. Replacement timing depends on pool use, debris, and water chemistry, so use the condition of the cartridge rather than a calendar date. When you order a new one, match the model and the surface area listed, such as the Zodiac R0554500 at 85 square feet per cartridge.
How do I read a pool flow meter, and what range do I need?
Read the flow rate at the marker or scale on the meter while the pump is running, and check the meter regularly for debris or mineral buildup. Our flow meter guide says residential pools typically run about 30 to 50 GPM, so the range matters. The Rola-Chem 570371V covers 80 to 300 GPM and suits higher-flow systems, while the H2Flow Controls FV-15 is a 1.5 inch CPVC meter rated to 50 psi. Pick a meter whose range and pipe size match your plumbing and pump. See the full list of pool and spa flow meters.
What do I need to install an underwater pool or spa light?
Check the niche size, the voltage, the cord length, and the transformer. The Spa Electrics A3 Atom 3 inch light runs on 10.5 to 13 volts AC and requires a 12 volt AC UL-listed transformer, and the Retro R10 fits 10 inch niches with a universal retrofit design. Under the National Electrical Code, low-voltage fixtures are fed from a transformer whose output stays at or below the 15 volt AC low-voltage contact limit. Pool wiring is regulated, so have a licensed electrician handle installation and check local code. Browse pool lights by size and voltage.
Are these parts for pools, spas, or both?
Both, and the listing tells you which. The LX Pumps 56WUA400-II and Balboa 5235212-S are spa pumps, the Air Supply 6310241 blower is for hot tubs and spas, and the Balboa 16-5200WHT jet is listed for pools and spas. Pool filters, motors, and lights are listed for the equipment they fit. Read the application and compatibility notes before ordering, and send us the model number if you are unsure.
Can I use a stainless steel ladder in a saltwater pool?
Check the listing first. The S.R.Smith VLLS-104E economy ladder is made of Type 304 and 316L stainless steel tubing and is marked Salt Friendly: No on its listing, so it is not listed for saltwater pools. If you have a saltwater pool, look for a ladder or rail that states it is salt friendly. See the full range of pool and deck safety products.