The SOUTHWIRE 962634606 is a Category 5e riser-rated data and voice cable designed for structured wiring installations in commercial and residential buildings. Built on 24 AWG solid copper conductors arranged in four unshielded twisted pairs, this cable carries a CMR jacket rating that qualifies it for vertical runs between floors without the need for conduit in many code-compliant applications. The polyethylene-insulated conductors are jacketed in PVC and tested to 100 MHz, meeting or exceeding TIA/EIA 568-C.2 specifications. It is ETL Listed for CMR and C(ETL) Listed CMR FT4. Licensed electricians and low-voltage cabling contractors are the primary installers.
This cable is suited for structured cabling systems supporting Gigabit Ethernet, 100Base-T, Fast Ethernet, T1, ISDN, and broadband video distribution. The 1,000 ft reel-in-box format is sized for full-floor or multi-room pulls in new construction and retrofit projects. The blue jacket aids circuit identification in telecom rooms and patch panels. The cable is TAA/BAA compliant and GSA approved, making it eligible for government and federal facility projects.
Key Features
Category 5e performance tested to 100 MHz, meeting TIA/EIA 568-C.2
CMR riser jacket rating for vertical runs between building floors
24 AWG solid bare copper conductors for consistent signal integrity in permanent installations
Unshielded twisted pair (UTP) construction with polyethylene insulation
PVC outer jacket rated at 300 volts AC
TAA/BAA compliant and GSA approved for government procurement
1,000 ft reel-in-box format reduces pull-through time on larger jobs
Compatibility
Designed as a CMR-rated Cat 5e replacement or new-installation cable for structured data and voice cabling systems supporting Gigabit Ethernet, 100Base-T, Fast Ethernet, T1, ISDN, and broadband video applications.
Installation Notes
Installation should be performed by a licensed electrician or certified low-voltage cabling contractor in accordance with NEC Article 800 requirements for communications wiring. De-energize any adjacent circuits before beginning the pull and confirm the riser pathway meets local fire-stop code requirements at each floor penetration. Avoid exceeding the cable's minimum bend radius during the pull to prevent damage to the twisted pairs. Terminate to keystone jacks or patch panels rated for Cat 5e or higher.
WARNING:
This product can expose you to chemicals including lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.