The SOUTHWIRE 11584058 is a 500-foot roll of 14 AWG solid copper THHN building wire with yellow insulation, rated for 600 volts and 90 degrees C. It is designed for power, lighting, and control wiring applications in commercial and residential construction. The conductor is solid copper, insulated with flame-retardant PVC and protected by a nylon outer jacket. This combination provides resistance to oil, gasoline, chemicals, and abrasion, making it a reliable choice for installations where wire is pulled through conduit or raceways. Licensed electricians and electrical contractors are the primary installers of this product.
This wire is suited for branch-circuit wiring, lighting circuits, and control runs in both residential and light commercial buildings. It is intended for use in conduit and raceway systems where THHN-rated conductors are required by code. The yellow color coding aids in quick identification during installation and service. Its solid conductor construction makes it well suited for home runs and straight pulls where flexibility is not a primary requirement.
Key Features
14 AWG solid copper conductor for reliable conductivity and code-compliant branch-circuit use
600-volt rating suitable for standard building power, lighting, and control applications
90 degrees C temperature rating for use in dry and wet locations where THHN is permitted
Flame-retardant PVC insulation with nylon jacket resists oil, gasoline, chemicals, and abrasion
Yellow outer color for easy conductor identification in multi-wire installations
UL listed to meet code requirements for general-purpose building wire
Compatibility
Designed as a general-purpose THHN building wire for use in conduit and raceway systems in residential and commercial electrical installations where 14 AWG, 600-volt, solid-conductor wire is specified.
Installation Notes
Installation should be performed by a licensed electrician in accordance with the National Electrical Code (NEC) and applicable local codes. De-energize the circuit and verify with a meter before making any connections. This wire is rated for use in conduit and raceways and should not be run as a free-air or direct-burial conductor unless the installation method is independently rated for those conditions. Observe minimum bend radius requirements when pulling through conduit to avoid insulation damage.