The EDWARDS G4SVWF is a wall-mounted speaker-strobe unit designed for fire alarm notification in commercial and institutional life-safety systems. It combines high-intelligibility audio output with a field-selectable strobe rated from 15 to 110 candela, making it adaptable to a wide range of notification zone requirements. The unit operates on 25 VRMS or 70 VRMS audio circuits, selectable in the field, and offers four wattage tap settings: 1/4W, 1/2W, 1W, and 2W. The 520 Hz audio capability supports low-frequency tone requirements increasingly specified in updated fire alarm codes. Installation is room-side, keeping wire terminations accessible during commissioning and service.
The G4SVWF is suited for use in commercial office buildings, schools, healthcare facilities, hotels, and similar occupancies where wall-mounted audible-visible notification is required. The white finish with FIRE marking meets common AHJ aesthetic and labeling requirements. Field-selectable strobe intensity and wattage taps allow a single SKU to cover multiple notification zone designs, reducing the need to stock multiple device variants. Licensed fire alarm technicians and low-voltage contractors typically specify and install this device as part of a listed fire alarm control panel system.
Key Features
Field-selectable strobe output from 15 to 110 candela to meet varying candela placement requirements
Dual-voltage audio operation at 25 VRMS or 70 VRMS, selectable in the field
Four wattage taps (1/4W, 1/2W, 1W, 2W) for flexible circuit loading
520 Hz audio capability for low-frequency notification compliance
Energy-efficient LED strobe technology with approximately 1 flash per second
Room-side wiring installation simplifies rough-in and final termination
White housing with FIRE marking for code-compliant device identification
Compatibility
Designed as an OEM-style wall notification appliance for use with listed fire alarm control panels that support 25 VRMS or 70 VRMS audio distribution circuits.
Installation Notes
Installation must be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and applicable local codes. De-energize the fire alarm control panel audio and notification appliance circuits before making wire terminations. Strobe candela and wattage tap selections should be confirmed against the system designer's notification appliance circuit calculations prior to final installation. Verify AHJ requirements for device placement height and candela rating before mounting.