EDWARDS Edwards EOL-4K7L Supervision Resistor 4.7K Ohm Crc

Edwards EOL-4K7L Supervision Resistor 4.7K Ohm Crc

Brand: EDWARDS
SKU: EOL-4K7L
Availability: In Stock

Ships same day if ordered by 12 pm

$32.05
$32.05
HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The EDWARDS EOL-4K7L is a 4.7K ohm end-of-line supervision resistor used in Controlled Releasing Circuits (CRC) and other supervised auxiliary loops in fire alarm and access control systems. Its primary function is to maintain line supervision on a CRC when no powered door strike or electric lock is connected to the circuit. Without this resistor in place, the fire alarm control panel would read the unloaded circuit as an open fault rather than a normal, supervised condition. Licensed fire alarm technicians install this component during system commissioning or when a releasing circuit is configured without a connected lock device.

The EOL-4K7L is designed for use in supervised releasing circuit applications where door strikes or electric locks are absent from the loop. It is typically installed at the end of the line in a CRC within a fire alarm system to satisfy supervision requirements imposed by NFPA 72 and similar codes. This resistor is a small but critical component that keeps the control panel from reporting a nuisance fault on circuits intentionally left without an electromagnetic locking device.

Key Features

  • 4.7K ohm resistance value maintains proper line supervision on unloaded CRC loops
  • Prevents false open-circuit faults on supervised releasing circuits with no connected lock or strike
  • End-of-line placement keeps the control panel in a normal supervisory state
  • Suitable for use in fire alarm and access control releasing circuit configurations

Compatibility

Designed for use in Controlled Releasing Circuits (CRC) and supervised auxiliary loops where no powered door strike or electric lock is connected. Specific panel compatibility was not provided; verify fitment against the control panel's installation manual before use.

Installation Notes

Installation should be performed by a licensed fire alarm technician in accordance with NFPA 72 and applicable local codes. De-energize the fire alarm control panel and place it in test mode before accessing any supervised circuit. The resistor is placed at the end of the supervised line to simulate a normal load on the circuit. Consult the control panel's wiring diagram to confirm the correct resistance value required for the specific CRC supervision configuration.

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

Technical Specifications
Resistance
4.7K ohm
Application
End-of-line supervision for Controlled Releasing Circuits (CRC)
Brand
EDWARDS
Manufacturer Part Number
EOL-4K7L