The EDWARDS 757-8A-RS25W is a 110 candela re-entrant speaker/strobe combination device designed for life safety notification in commercial and institutional fire alarm systems. Operating at 25 volts DC and listed under UL 1971 and UL 464, this wall-mounted unit delivers synchronized visual strobe output alongside audible speaker notification in a single housing. The 110 cd strobe output meets sleeping area requirements as defined by NFPA 72, making it suitable for dormitories, patient rooms, and hotel applications where higher candela output is mandated. Fire alarm technicians and low-voltage contractors install this device as part of addressable or conventional notification appliance circuits.
This device is specified in commercial and institutional environments where both audible and visual notification are required. Typical applications include healthcare facilities, educational institutions, office buildings, and industrial settings. The re-entrant speaker design improves sound projection and speech intelligibility in spaces with complex acoustic profiles such as corridors, open floor plans, and hard-surface rooms. The white housing is intended for wall-mount installation in vertical orientation, blending with standard commercial interior finishes while maintaining code-visible strobe placement.
Key Features
110 candela strobe output meets NFPA 72 sleeping area requirements
Combined speaker/strobe in a single wall-mount housing reduces installation points
UL 1971 listed for visible notification appliances
UL 464 listed for audible signaling appliances
Operates at 25 volts DC for compatibility with standard notification appliance circuits
Re-entrant speaker geometry improves audio intelligibility in reverberant environments
White finish with vertical wall orientation for code-compliant placement
Compatibility
Designed for use in fire alarm notification appliance circuits requiring UL 1971 listed visual appliances and UL 464 listed audible appliances per NFPA 72. No specific panel or system family compatibility was provided in the product data.
Installation Notes
Installation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and applicable local codes. De-energize the notification appliance circuit at the fire alarm control panel before wiring or mounting the device. Confirm strobe synchronization module requirements at the control panel to maintain UL 1971 compliance when multiple strobes are installed in the same field of view. Mount in the specified vertical wall orientation to preserve the listed candela rating.