EDWARDS Edwards 276B-1120 Fire Alarm Pull Station Key Reset

Edwards 276B-1120 Fire Alarm Pull Station Key Reset

Brand: EDWARDS
SKU: 276B-1120
Availability: In Stock

Ships same day if ordered by 12 pm

$53.73
$53.73
HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The EDWARDS 276B-1120 is a non-coded, single-action manual fire alarm pull station designed for use in commercial and institutional fire alarm initiating circuits. Part of the 276B series, it is constructed from Lexan polycarbonate and features a single-pole, open-circuit configuration with screw terminals for field wiring connections. The station uses a key-operated reset, requiring authorized personnel to restore the device after activation. When installed on a circuit shared with smoke detectors, a resistor can be added in series with the alarm initiating contacts to prevent the station's operation from extinguishing alarm LEDs on activated detectors.

The 276B-1120 is suited for surface or semi-flush mounting in commercial buildings, schools, healthcare facilities, and other occupancies requiring manual fire alarm initiation points. For semi-flush mounting, a standard North American 4-inch square box with a single-gang plaster cover and a minimum overall depth of 2.25 inches is required. For surface mounting, the compatible Cat. No. 276B-RSB surface back box is the appropriate enclosure. This station is installed by licensed fire alarm technicians in accordance with NFPA 72 and applicable local codes.

Key Features

  • Single-action activation with break-glass operation for fast, intuitive deployment
  • Single-pole, open-circuit design compatible with standard fire alarm initiating device circuits
  • Key-operated reset prevents unauthorized restoration after activation
  • Screw terminal connections support field wiring without special tooling
  • Lexan polycarbonate housing provides durability and contemporary styling
  • UL and CSFM certified for use in code-compliant fire alarm systems

Compatibility

Designed as an OEM-style replacement or new-installation pull station for use with standard fire alarm control panel initiating device circuits. Compatible with the Cat. No. 276B-RSB surface back box for surface-mount applications.

Installation Notes

Installation must be performed by a licensed fire alarm technician in compliance with NFPA 72 and applicable local authority having jurisdiction requirements. De-energize and isolate the initiating device circuit before making any wiring connections at the screw terminals. Verify mounting box depth meets the 2.25-inch minimum before semi-flush installation. Do not restore the station to service after testing without using the proper reset key.

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

Technical Specifications
Circuit Type
Single-pole, open circuit
Action Type
Single action
Reset Type
Key operated
Terminal Type
Screw terminal
Housing Material
Lexan polycarbonate
Mounting Location
Surface or flush
Operating Temperature
32 degrees F to 70 degrees F
Operating Humidity
95%
Certifications
UL, CSFM
Length
5 inches
Width
5 inches
Height
3 inches
Weight
1.52 pounds
Brand
EDWARDS
Manufacturer Part Number
276B-1120
EDWARDS Edwards 276B-1120 Fire Alarm Pull Station Key Reset

Vendor: EDWARDS

Edwards 276B-1120 Fire Alarm Pull Station Key Reset

$53.73

Vendor: EDWARDS

Edwards 276B-1120 Fire Alarm Pull Station Key Reset

$53.73

Related Products

Customer Support Image

Need Support?

Call Jack and His Team