The EDWARDS 1508-AQN5 is a heavy-duty electromagnetic door holder designed for surface wall mount installation in commercial and institutional life-safety applications. The unit operates on 24 volts AC/DC or 120 volts AC, drawing only 0.015 amps, making it compatible with a wide range of fire alarm and access control panel outputs. The housing is die cast metal finished in a durable baked polyester powder paint in silver, built to withstand the demands of high-traffic corridors and stairwell doors. It delivers a holding force of up to 25 pounds. A shock-absorbing nylon swivel ball on the contact plate allows the plate to self-adjust to door angle, ensuring consistent magnetic contact across varying door positions.
This door holder is suited for surface wall mount installations in commercial buildings, schools, healthcare facilities, and similar occupancies where fire-rated corridor doors must be held open during normal operations and released automatically upon fire alarm activation. The electromagnet section mounts to the wall while the contact plate attaches to the door. It is appropriate for single-door applications requiring a fail-safe, power-to-hold design. Electricians and fire alarm technicians typically install this unit as part of a door release system tied to a fire alarm control panel.
Key Features
Fail-safe operation: door releases automatically when power is interrupted by a fire alarm signal
Dual voltage input: accepts 24 volts AC/DC or 120 volts AC for flexible panel integration
Low current draw of 0.015 amps minimizes load on fire alarm or access control circuits
Die cast metal housing with baked polyester powder paint finish for durability in high-traffic areas
Shock-absorbing nylon swivel ball on contact plate self-adjusts to door angle
Surface wall mount design simplifies retrofit and new construction installation
Compatibility
Designed as an OEM-style surface wall mount electromagnetic door holder suitable for single-door fire-rated corridor applications in commercial and institutional buildings.
Installation Notes
Installation should be performed by a licensed electrician or certified fire alarm technician in accordance with NFPA 72, the National Electrical Code, and applicable local authority having jurisdiction requirements. Disconnect and lock out all power to the circuit before wiring the unit. The electromagnet body mounts to the wall at a height that aligns the contact plate on the door; verify door swing and gap before final fastening. Do not energize the unit until all wiring connections are confirmed and the contact plate is properly secured to the door.