The COMMAND ACCESS TECHNOLOGIES ETH6W4040 626 CH-BB79 is a full-mortise electrified power transfer hinge designed to route low-voltage wiring from the hinge jamb to the door-mounted lockset or access control device without exposed wires. Built on a steel base with a US26D satin chrome finish, it measures 4 inches by 4 inches and uses a 6-wire, 26-gauge conductor configuration. The 5/8-inch radius corners match standard commercial door prep. With a 5-knuckle, plain-bearing, non-removable-pin construction, it provides the mechanical performance of a standard commercial hinge while delivering the electrical continuity required for electrified hardware installations.
This hinge is intended for commercial door applications where low-voltage power must cross the hinge line cleanly. It is commonly installed on doors fitted with electric mortise locks, electric cylindrical locks, electric strikes on pairs of doors, electric exit trims, latch pullback devices, door-mounted card readers, and low-voltage door lights. The concealed wiring path eliminates the need for external wire loops or surface-mounted conduit at the hinge, keeping the installation code-compliant and aesthetically clean in commercial entryways, office suites, and institutional facilities.
Key Features
6-wire, 26-gauge (6-26GA) conductor path transfers low-voltage power across the hinge line with no visible wiring
Full-mortise hinge type fits standard commercial door and frame prep
4 x 4 inch leaf size with 5/8-inch radius corners for common commercial door specifications
Steel base material with US26D satin chrome finish for durability and consistent appearance
5-knuckle, plain-bearing construction with non-removable pin for security
Compatible with a wide range of electrified locksets, exit trims, and access control devices
Compatibility
Designed for use with electric mortise locks, electric cylindrical locks, electric strikes on pairs of doors, electric exit trims, latch pullback devices, door-mounted card readers, and low-voltage door lights in commercial installations.
Installation Notes
Installation is typically performed by a licensed locksmith, door hardware specialist, or low-voltage access control technician. Disconnect and lock out all power to the access control system before wiring or handling the hinge conductors. Follow local building codes and applicable NFPA 70 (NEC) low-voltage wiring requirements when routing and terminating conductors. Do not exceed the voltage or current ratings of the hinge conductors, and avoid sharp bends or pinch points in the wire path during door installation.