The BEA 10MAGLOCK5UL is a double electromagnetic surface mount lock designed for access control applications requiring high holding force and reliable operation. Rated at 1200 pounds holding force, it operates on 12 or 24 volts DC and carries UL and ULC listings, which require a UL Listed power supply for compliant installation. The lock includes an integrated LED status indicator, a lock status sensor with selectable normally open or normally closed outputs, and a single bond status relay. A built-in hold open timer is adjustable from 0 to 90 seconds, allowing the door to relock automatically after a timed release cycle.
This electromagnetic lock is suited for double-door commercial and institutional entry points where surface mounting is required. Typical installations include office buildings, schools, hospitals, and secured facilities where both door leaves must be held simultaneously. The selectable NO/NC sensor outputs offer flexibility for integration with a variety of access control panels and alarm systems. The adjustable relock timer reduces the need for separate timer modules in the control circuit.
Key Features
1200-pound holding force for double-door surface mount applications
Operates on 12 or 24 volts DC for compatibility with common access control power supplies
UL and ULC Listed - requires a UL Listed power supply for code-compliant installation
Integrated LED status indicator for quick visual verification of lock state
Lock status sensor with selectable normally open or normally closed outputs for panel integration
Adjustable hold open timer from 0 to 90 seconds for automatic relock after door release
Single bond status relay included for monitoring door bond condition
Compatibility
Designed as an OEM-style electromagnetic lock for double-door surface mount access control installations. Compatible with access control systems that accept dry contact NO or NC door status inputs. A UL Listed power supply capable of supplying 12 or 24 volts DC is required for listed operation.
Installation Notes
Installation should be performed by a licensed low-voltage or access control technician familiar with applicable codes, including NFPA 101 and local authority having jurisdiction requirements for electromagnetic locks on egress paths. Disconnect and lock out all power to the access control system before mounting or wiring the lock. Confirm that the power supply carries a UL Listing and is rated for the selected operating voltage before energizing. Verify sensor output polarity and timer settings match the connected access control panel configuration before placing the system in service.