Product Description

The THHNCU-GENERIC thhn2stryelmr is a 2 AWG stranded copper THHN building wire with yellow PVC insulation and a nylon jacket, rated for use in dry and wet locations up to 90 degrees C. Constructed with 19 strands of copper for flexibility during pull-through in conduit runs, this wire carries a 600-volt rating and delivers ampacity of 95 amps at 60 degrees C, 115 amps at 75 degrees C, and 130 amps at 90 degrees C. Electricians use it for branch circuit wiring, feeder runs, and panel connections in commercial and residential installations. The outer diameter measures 0.381 inches and weight runs 241 pounds per thousand feet.

This wire is suited for conduit-installed branch circuit and feeder applications in both residential and commercial construction. The yellow insulation color aids in phase identification and circuit tracing during installation and maintenance. It is commonly pulled through EMT, rigid metal conduit, or PVC conduit in service entrance, subpanel feeder, and large-load branch circuit work. Licensed electricians install this wire in compliance with NEC requirements for conductor sizing, ampacity derating, and conduit fill calculations.

Key Features

  • 2 AWG copper conductor with 19-strand construction for improved flexibility during conduit pulls
  • THHN type rating — suitable for dry and wet locations up to 90 degrees C
  • 600-volt rating covers standard commercial and residential power distribution applications
  • Ampacity up to 130 amps at 90 degrees C per NEC temperature correction guidelines
  • Yellow PVC insulation with nylon jacket for abrasion resistance and pull-through durability
  • Outer diameter of 0.381 inches — factor into conduit fill calculations per NEC Chapter 9

Compatibility

Designed as a general-purpose THHN building wire for use in conduit systems where 2 AWG copper conductor wire meeting 600-volt, 90 degrees C insulation standards is specified.

Installation Notes

Installation must be performed by a licensed electrician in accordance with the National Electrical Code and applicable local codes. De-energize and lock out the circuit before terminating conductors at any panel, disconnect, or device. Use appropriate wire-pulling lubricant and verify conduit fill does not exceed NEC limits for the conduit type and size. Confirm terminal ratings at lugs and breakers are rated for the conductor temperature rating being applied.

Technical Specifications

  • Conductor Material: Copper
  • Conductor Size: 2 AWG
  • Stranding: 19 Strand
  • Ampacity: 95 amps at 60 degrees C, 115 amps at 75 degrees C, 130 amps at 90 degrees C
  • Voltage Rating: 600 volts
  • Temperature Rating: 90 degrees C (Dry/Wet)
  • Insulation Material: PVC
  • Jacket Material: Nylon
  • Insulation Color: Yellow
  • Outer Diameter: 0.381 inches
  • Weight: 241 pounds per 1,000 feet
  • Wire Type: THHN

Standard Information

  • Brand: THHNCU-GENERIC
  • Manufacturer Part Number: thhn2stryelmr