The SOUTHWIRE 32151106 is an 18 AWG, 4-conductor stranded bare copper multiconductor cable with an overall aluminum shield, rated for plenum air-handling spaces. The jacket and insulation are both constructed from low-smoke PVC (LS-PVC), meeting CMP and FT6 ratings for installations in air ducts, raised floors, and plenum ceilings where flame spread and smoke density requirements are strictly enforced. This cable ships in a 1000-foot REELEX pull box that feeds smoothly during installation, reducing kinking and tangles. It is a standard choice for licensed low-voltage technicians and security system installers working in commercial and institutional environments.
This cable is designed for use in security, access control, and general low-voltage control wiring applications where plenum-rated cabling is required by code. The aluminum overall shield provides protection against electromagnetic interference, making it well suited for signal-sensitive runs in commercial buildings, hospitals, schools, and office environments. The blue jacket aids in visual identification during rough-in and service work. Installers running cable through HVAC plenum spaces, above drop ceilings, or through air-handling cavities will find this cable appropriate for those regulated environments.
Designed as a plenum-rated multiconductor shielded cable for security, access control, and low-voltage control wiring applications in commercial and institutional buildings where CMP-rated cable is required by the National Electrical Code or local authority having jurisdiction.
Installation should be performed by a licensed low-voltage or electrical contractor in accordance with NFPA 70 (NEC) Article 800 and applicable local codes governing plenum-rated communications and control cable. De-energize all associated control circuits and verify lockout before making terminations. Maintain minimum bend radius during the pull to avoid degrading the aluminum shield continuity. The REELEX pull box should remain stationary during the pull; do not place tension on the box itself.
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
We pulled together the parts most installs need for this unit, plus a few add-ons worth a look. Check what you need — nothing here blocks checkout.
Add install kit to cart
—
Thanks for subscribing!
This email has been registered!