The DAIKIN FDMA24AVJU9 is a concealed ducted indoor air handler rated at 24,000 BTU/h for both heating and cooling, designed for single-zone mini split systems using R-32 refrigerant. It operates on 208/230V single-phase power and integrates inverter-driven capacity modulation for efficient part-load operation. The low-profile cabinet measures 39.38 inches wide, 9.63 inches tall, and 31.50 inches deep, allowing installation above ceilings or in tight mechanical spaces where a standard air handler would not fit. Built-in Wi-Fi enables remote monitoring and control. Licensed HVAC technicians handling R-32 systems install this unit as part of a ducted mini split setup serving residential or light-commercial applications.
The FDMA24AVJU9 is suited for single-zone ducted applications where the indoor unit must remain hidden from the occupied space. The unit connects to existing or new low-static ductwork and supports three selectable fan speeds with adjustable external static pressure settings to match the duct system design. It is paired with a compatible Daikin Aurora RXP-series outdoor condenser - such as the RXP24AVJU9 - to form a complete heat pump system capable of heating operation down to -13 degrees F ambient and cooling operation from 50 degrees F to 115 degrees F, with system efficiencies up to 18.3 SEER2 and up to 9.2 HSPF2 when matched with that outdoor unit.
The FDMA24AVJU9 is the indoor air handler component of the Daikin Aurora single-zone ducted mini split system and is matched with the RXP24AVJU9 outdoor condenser to form an 18.3 SEER2 system. Confirm outdoor unit compatibility with Daikin documentation before installation.
Installation must be performed by an EPA Section 608-certified HVAC technician familiar with R-32 flammable refrigerant handling procedures. Shut off all electrical power to the system before making any wiring or refrigerant connections. R-32 requires the use of tools and components rated for A2L refrigerants; follow applicable local mechanical codes and manufacturer installation instructions for minimum clearances, drain line routing, and duct connection sizing. Do not commission the refrigerant circuit until all connections are leak-tested and the system is properly evacuated.