Customer Support Image
Need Support?

Call Jack and His Team

Voomi Supply carries HVAC thermostats from Resideo, Honeywell, Aprilaire, White-Rodgers, Marley and Goodman, in programmable, non-programmable, WiFi smart, line voltage, electric heat and pneumatic types across low voltage and line voltage ratings. A thermostat senses room temperature and switches heating, cooling or fan equipment to hold the setpoint, and zoning uses several thermostats with motorized dampers so different areas of a building can be controlled separately. Every order ships with Voomi's 30-day return policy and free help matching a thermostat to your system.

Thermostat Types We Carry

Type

What it does

Typical use

Programmable thermostats

Runs a schedule so the setpoint changes by time of day

Homes and offices with regular occupancy

Non-programmable thermostats

Holds one setpoint that you set by hand

Simple replacements and rooms with steady use

WiFi & smart thermostats

Adds app control and remote scheduling over WiFi

Homes where remote control or usage reports are wanted

Line voltage thermostats

Switches 120V or 240V power directly to the heater

Electric baseboards, convectors and wall heaters

Electric heat thermostats

Controls electric heating equipment

Baseboard and other electric heaters

Pneumatic thermostats

Controls equipment through air pressure signals instead of electrical ones

Buildings with pneumatic control systems

Thermostat parts

Sensors, covers and replacement components

Repairs to an existing thermostat

Programmable Thermostats for Ultimate Convenience

Take control of your HVAC system with our programmable thermostats, designed to maximize comfort and energy savings. These thermostats allow you to set schedules, ensuring your home stays at the perfect temperature when you need it most.

WiFi Thermostats for Smart Home Integration

Integrate your HVAC system into your smart home with our WiFi thermostats. These devices allow you to control your home’s temperature from anywhere using your smartphone, providing both comfort and convenience at your fingertips. ENERGY STAR reports average savings of about 8 percent of heating and cooling bills, or about $50 per year, for certified smart thermostats, with more savings in climates with large seasonal swings and less in homes that are always occupied.

Low Voltage vs Line Voltage Thermostats

This is the first thing to check, because the two kinds are not interchangeable.

 

Low voltage (24V)

Line voltage (120V or 240V)

What it does

Signals the equipment to turn on or off and does not power the heater

Acts as an in-line switch that sends power straight to the heater

Found on

Furnaces, central air conditioners, heat pumps, boilers, PTAC units and fan coils

Electric baseboards, convectors, wall heaters and in-floor heating

Wiring

Thin multi-colored wire to terminals such as R, W, Y, G and C

Thick wire, typically 12 or 14 gauge, often on its own breaker

Safety

Still switch off power before opening the cover

Turn off the breaker before opening the faceplate, since 120V or 240V can cause serious injury

Reading Low Voltage Thermostat Terminals

Terminal

What it does

R (Rc / Rh)

24V power from the transformer. Dual-transformer systems use Rh for heating and Rc for cooling.

C

Common wire that supplies continuous 24VAC to power the thermostat

W1 / W2

First and second heating stages on conventional systems, or auxiliary heat on a heat pump

Y1 / Y2

First and second cooling stages on conventional systems, or compressor stages on a heat pump

G

Fan

O/B

Reversing valve on heat pump systems

E

Emergency heat on heat pump systems

Terminal labels follow common practice, but check the wiring diagram of your own equipment.

How HVAC Zoning Works

Zoning lets one heating and cooling system serve several areas with separate temperature control. A zoned system usually includes the parts below.

Component

Role

Zone dampers

Motorized dampers on the supply ducts open and close to send air only where it is needed. There can be a few large dampers or one per outlet.

Thermostats or sensors

Each zone has its own thermostat, or one master thermostat works with small temperature sensors in each zone

Zone control board

Sits near the air handler and connects the thermostats, the dampers and the air handler control board with low voltage wiring

Bypass duct and damper

Routes supply air back to the return when zones close to relieve supply plenum pressure. It stays closed when all zones are open. A barometric bypass damper opens on its own using an adjustable weight.

How to Choose a Thermostat

Check

What to compare

Voltage

Low voltage (24V) or line voltage (120V or 240V), and the amperage of the load

Equipment type

Furnace and air conditioner, heat pump, electric baseboard, fan coil or pneumatic system

Stages

The number of heating and cooling stages your equipment has, such as 2 heat and 1 cool

Heat pump support

O/B and auxiliary or emergency heat terminals if you have a heat pump

C wire

Whether the thermostat needs a common wire and whether your wiring has one

Features

Schedule, WiFi, sensors or a plain manual dial

Browse the parent category: HVAC parts & supplies.

Frequently Asked Questions

A programmable thermostat follows a schedule you set on the device. A smart thermostat does that and adds WiFi, so you can change the setpoint from an app, and many models add learning, sensors or usage reports. Both are low voltage in most homes, so confirm your system before you buy. See our programmable thermostats.

ENERGY STAR reports average savings of about 8 percent of heating and cooling bills, or about $50 a year, and says savings vary with climate, comfort preferences and occupancy. Homes with variable-capacity heat pumps or air conditioners generally do best with the thermostat the equipment maker recommends. See WiFi & smart thermostats.

Usually not. Baseboard heaters normally run on 120V or 240V and need a line voltage thermostat that switches the heater power directly. A 24V thermostat only signals equipment and cannot carry that load. Turn off the breaker before opening any thermostat. See line voltage thermostats.

The C (common) wire supplies continuous 24VAC to power the thermostat, which matters for WiFi and touchscreen models. If your wiring has no C wire, check the thermostat specifications, since some models include an adapter or can run without one, and ask us before you buy.

Choose a thermostat that lists heat pump support. It needs an O/B terminal to control the reversing valve and usually terminals for auxiliary or emergency heat. Stage count matters too, since many heat pumps use more than one compressor stage.

A zone control board connects separate thermostats or sensors to motorized dampers in the ducts. When a zone calls for heating or cooling, its damper opens and others close, and a bypass damper relieves the extra pressure. Zoning is matched to the air handler, so ask us before you plan a retrofit.