Voomi Supply carries HVAC thermostats from Resideo, Honeywell, Aprilaire, White-Rodgers, Marley and Goodman, in programmable, non-programmable, WiFi smart, line voltage, electric heat and pneumatic types across low voltage and line voltage ratings. A thermostat senses room temperature and switches heating, cooling or fan equipment to hold the setpoint, and zoning uses several thermostats with motorized dampers so different areas of a building can be controlled separately. Every order ships with Voomi's 30-day return policy and free help matching a thermostat to your system.
|
Type |
What it does |
Typical use |
|
Runs a schedule so the setpoint changes by time of day |
Homes and offices with regular occupancy |
|
|
Holds one setpoint that you set by hand |
Simple replacements and rooms with steady use |
|
|
Adds app control and remote scheduling over WiFi |
Homes where remote control or usage reports are wanted |
|
|
Switches 120V or 240V power directly to the heater |
Electric baseboards, convectors and wall heaters |
|
|
Controls electric heating equipment |
Baseboard and other electric heaters |
|
|
Controls equipment through air pressure signals instead of electrical ones |
Buildings with pneumatic control systems |
|
|
Sensors, covers and replacement components |
Repairs to an existing thermostat |
Take control of your HVAC system with our programmable thermostats, designed to maximize comfort and energy savings. These thermostats allow you to set schedules, ensuring your home stays at the perfect temperature when you need it most.
Integrate your HVAC system into your smart home with our WiFi thermostats. These devices allow you to control your home’s temperature from anywhere using your smartphone, providing both comfort and convenience at your fingertips. ENERGY STAR reports average savings of about 8 percent of heating and cooling bills, or about $50 per year, for certified smart thermostats, with more savings in climates with large seasonal swings and less in homes that are always occupied.
This is the first thing to check, because the two kinds are not interchangeable.
|
|
Low voltage (24V) |
Line voltage (120V or 240V) |
|
What it does |
Signals the equipment to turn on or off and does not power the heater |
Acts as an in-line switch that sends power straight to the heater |
|
Found on |
Furnaces, central air conditioners, heat pumps, boilers, PTAC units and fan coils |
Electric baseboards, convectors, wall heaters and in-floor heating |
|
Wiring |
Thin multi-colored wire to terminals such as R, W, Y, G and C |
Thick wire, typically 12 or 14 gauge, often on its own breaker |
|
Safety |
Still switch off power before opening the cover |
Turn off the breaker before opening the faceplate, since 120V or 240V can cause serious injury |
|
Terminal |
What it does |
|
R (Rc / Rh) |
24V power from the transformer. Dual-transformer systems use Rh for heating and Rc for cooling. |
|
C |
Common wire that supplies continuous 24VAC to power the thermostat |
|
W1 / W2 |
First and second heating stages on conventional systems, or auxiliary heat on a heat pump |
|
Y1 / Y2 |
First and second cooling stages on conventional systems, or compressor stages on a heat pump |
|
G |
Fan |
|
O/B |
Reversing valve on heat pump systems |
|
E |
Emergency heat on heat pump systems |
Terminal labels follow common practice, but check the wiring diagram of your own equipment.
Zoning lets one heating and cooling system serve several areas with separate temperature control. A zoned system usually includes the parts below.
|
Component |
Role |
|
Zone dampers |
Motorized dampers on the supply ducts open and close to send air only where it is needed. There can be a few large dampers or one per outlet. |
|
Thermostats or sensors |
Each zone has its own thermostat, or one master thermostat works with small temperature sensors in each zone |
|
Zone control board |
Sits near the air handler and connects the thermostats, the dampers and the air handler control board with low voltage wiring |
|
Bypass duct and damper |
Routes supply air back to the return when zones close to relieve supply plenum pressure. It stays closed when all zones are open. A barometric bypass damper opens on its own using an adjustable weight. |
|
Check |
What to compare |
|
Voltage |
Low voltage (24V) or line voltage (120V or 240V), and the amperage of the load |
|
Equipment type |
Furnace and air conditioner, heat pump, electric baseboard, fan coil or pneumatic system |
|
Stages |
The number of heating and cooling stages your equipment has, such as 2 heat and 1 cool |
|
Heat pump support |
O/B and auxiliary or emergency heat terminals if you have a heat pump |
|
C wire |
Whether the thermostat needs a common wire and whether your wiring has one |
|
Features |
Schedule, WiFi, sensors or a plain manual dial |
Browse the parent category: HVAC parts & supplies.