Product Description

The WEST PENN WIRE D990RD1000 is a 16 AWG, 2-conductor solid-conductor direct-burial fire alarm cable supplied in a 1000-foot reel. Constructed for non-plenum installations, this cable carries a red jacket that meets standard color-coding conventions for fire alarm wiring. Solid conductors at 16 AWG provide reliable low-resistance signal transmission in initiating device circuits (IDC) and notification appliance circuits (NAC) within commercial and residential fire alarm systems. Licensed fire alarm technicians and low-voltage electricians are the primary installers of this cable type.

This cable is suited for non-plenum, non-air-handling-space applications including in-wall, conduit, and direct-burial runs where a rated plenum jacket is not required by the authority having jurisdiction. Typical install scenarios include connecting smoke detectors, pull stations, horn-strobes, and other fire alarm field devices back to a fire alarm control panel (FACP). The 1000-foot reel length supports larger commercial jobs and multi-floor residential installations with minimal splicing.

Key Features

  • 16 AWG solid conductors for low-resistance, stable signal transmission over long runs
  • 2-conductor configuration sized for standard IDC and NAC wiring loops
  • Red jacket for fire alarm circuit identification per common industry practice
  • Non-plenum (direct-burial rated) jacket appropriate for conduit, in-wall, and underground runs
  • 1000-foot reel reduces mid-run splices on large commercial or multi-unit jobs

Compatibility

Designed as a non-plenum, direct-burial fire alarm cable for use in standard 2-conductor initiating device and notification appliance circuit wiring in commercial and residential fire alarm systems.

Installation Notes

Installation must be performed by a licensed low-voltage electrician or fire alarm technician in accordance with NFPA 72 and applicable local codes. Always de-energize the fire alarm control panel and follow lockout/tagout procedures before making conductor connections. Non-plenum cable must not be routed through air-handling spaces or plenums where a CL2P, CMP, or FPL-rated jacket is required by code. Verify burial depth requirements with the authority having jurisdiction when running cable underground.

Technical Specifications
Conductor Size
16 AWG
Number of Conductors
2
Conductor Type
Solid
Jacket Color
Red
Cable Rating
Non-Plenum (Direct Burial)
Reel Length
1000 feet
Application Category
Fire Alarm / Non-Plenum Audio
Unit of Measure
Each (1 reel)
Brand
WEST PENN WIRE
Manufacturer Part Number
D990RD1000
WEST PENN WIRE West Penn Wire D990RD1000 16 Awg 2C Fire Alarm Cable 1000 Ft

Vendor: WEST PENN WIRE

West Penn Wire D990RD1000 16 Awg 2C Fire Alarm Cable 1000 Ft

$763.77

Vendor: WEST PENN WIRE

West Penn Wire D990RD1000 16 Awg 2C Fire Alarm Cable 1000 Ft

$763.77

Related Products

Customer Support Image

Need Support?

Call Jack and His Team