VALUE COLLECTION Value Collection RNB14-8 Ring Terminal 6 Awg Crimp 5/16

Value Collection RNB14-8 Ring Terminal 6 Awg Crimp 5/16

SKU: RNB14-8
Availability: In Stock

Ships same day if ordered by 12 pm

HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The VALUE COLLECTION RNB14-8 is a non-insulated circular ring terminal designed for crimp connections on 6 AWG copper wire. Used in electrical panel work, control wiring, and equipment grounding applications, this terminal provides a secure mechanical and electrical connection to a 5/16 inch stud. The copper contact construction ensures solid conductivity, and the uninsulated design is suited for installations where the terminal will be covered by a lug or landing that provides its own protection. Electricians and installers working in HVAC control panels, motor wiring, and industrial equipment will find this terminal sized and rated for everyday service work.

This ring terminal is intended for use in low-voltage and line-voltage wiring applications where a 6 AWG conductor must be terminated at a threaded stud or binding post. The crimp connection type requires a proper ratcheting or indent-style crimping tool to achieve a reliable termination. Applications include equipment grounding, panel bonding, motor lead terminations, and control circuit wiring in both residential and light commercial settings. Terminals of this type are sold in minimum order quantities of 25 units.

Key Features

  • Non-insulated design for use in covered or protected termination points
  • Crimp connection type for fast, consistent field installation
  • Copper contact material for reliable conductivity
  • Compatible with 6 AWG wire (14.00 sq mm)
  • Fits 5/16 inch stud size (8.40 mm)
  • CSA Certified, cUL Listed, UL Listed, and RoHS Compliant

Compatibility

Designed as a standard crimp-style ring terminal for 6 AWG conductors terminating at 5/16 inch studs, suitable for use in electrical panels, grounding applications, and motor wiring installations where a non-insulated lug is appropriate.

Installation Notes

Installation should be performed by a qualified electrician in accordance with NEC requirements for terminal and conductor sizing. De-energize the circuit completely before terminating or removing any ring terminal. Use a calibrated ratcheting crimping tool rated for the wire gauge and terminal type to ensure a gas-tight, mechanically secure crimp. Do not re-crimp or reuse a terminal that has already been seated on a conductor.

Technical Specifications
Terminal Type
Circular Ring
Insulation Type
Non-Insulated
Connection Type
Crimp
Compatible Wire Size
6 AWG (14.00 sq mm)
Stud Size
5/16 inches (8.40 mm)
Contact Material
Copper
Overall Length
1.28 inches
Ring Width
0.63 inches (16.00 mm)
Thickness
0.0590 inches
Weight
0.01 pounds
Certifications
CSA Certified, cUL Listed, UL Listed, RoHS Compliant
UNSPSC Code
39121432
Minimum Order Quantity
25
Brand
VALUE COLLECTION
Manufacturer Part Number
RNB14-8