PANDUIT Panduit P38D25M-BL1A Vertical Pdu 32 C13 6 C19

Panduit P38D25M-BL1A Vertical Pdu 32 C13 6 C19

Brand: PANDUIT
SKU: P38D25M-BL1A
Availability: In Stock

Ships same day if ordered by 12 pm

$3,465.39
$3,465.39
HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The PANDUIT P38D25M-BL1A is a vertical monitored power distribution unit (PDU) designed for rack-mounted data center and IT infrastructure applications. It provides 32 IEC C13 outlets and 6 IEC C19 outlets, supporting a wide range of server, storage, and networking equipment. The monitored design gives facility and IT technicians real-time visibility into power consumption at the unit level, supporting capacity planning and uptime management. This PDU mounts vertically within a standard equipment rack, keeping outlet density high while preserving rack unit space for active equipment.

The P38D25M-BL1A is suited for high-density server rack deployments in data centers, network closets, and server rooms. The combination of C13 and C19 outlets accommodates both standard 1U and 2U servers and higher-draw equipment such as rack-mounted UPS units and high-performance storage arrays. Installation is typically performed by licensed electricians or qualified data center technicians following NFPA 70 (NEC) guidelines and the facility power design specifications.

Key Features

  • 32 IEC C13 outlets for standard server and networking loads
  • 6 IEC C19 outlets for higher-current rack equipment
  • Monitored functionality provides unit-level power consumption data
  • Vertical mounting form factor preserves rack unit space
  • Single-unit quantity per package for straightforward procurement

Compatibility

Designed as an OEM-style vertical PDU for use in standard 2-post and 4-post equipment racks accommodating vertical-mount power distribution units with IEC C13 and C19 outlet configurations.

Installation Notes

Installation should be performed by a licensed electrician or qualified data center technician in accordance with NFPA 70 (NEC) and applicable facility electrical codes. De-energize the upstream circuit breaker and verify zero voltage at the input connection before mounting or wiring the unit. Ensure the rack structure is properly grounded before securing the PDU. Do not exceed the rated load capacity of the unit or any individual outlet bank.

Technical Specifications
Outlet Configuration
32 x IEC C13, 6 x IEC C19
Mounting Orientation
Vertical
Monitoring Type
Monitored (unit-level)
Unit of Measure
Each
Quantity Per Package
1
Brand
PANDUIT
Manufacturer Part Number
P38D25M-BL1A