PANDUIT Panduit P36F16M Metered Pdu 30A 30 C13 6 C19 Rackmount

Panduit P36F16M Metered Pdu 30A 30 C13 6 C19 Rackmount

Brand: PANDUIT
SKU: P36F16M
Availability: Out Of Stock
HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The PANDUIT P36F16M is a metered rack power distribution unit (PDU) rated for 30 amps and designed to distribute and monitor electrical power across multiple connected loads in a server rack or network enclosure. It provides 30 IEC C13 outlets and 6 IEC C19 outlets, supporting a mix of standard and high-draw equipment. The built-in metering function allows technicians to monitor real-time current draw at the unit level, helping prevent overloads and supporting capacity planning. This unit is intended for installation by qualified electricians or data center infrastructure technicians.

The P36F16M is suited for rackmount deployments in data centers, telecommunications rooms, network closets, and enterprise server environments. The combination of C13 and C19 outlet types accommodates servers, storage arrays, network switches, patch panels with active components, and other IT equipment with varying power requirements. The 30-amp rating makes it appropriate for high-density rack configurations where standard 20-amp circuits would be insufficient.

Key Features

  • 30-amp rated input for high-density rack power distribution
  • 30 IEC C13 outlets for standard IT equipment connections
  • 6 IEC C19 outlets for high-draw devices such as servers and storage
  • Metered design provides real-time current monitoring at the PDU level
  • Rackmount form factor for integration into standard equipment enclosures

Compatibility

Designed as an OEM-style rackmount PDU for use in standard 19-inch rack enclosures with equipment requiring IEC C13 and C19 power connections.

Installation Notes

Installation should be performed by a qualified electrician or trained data center technician in accordance with NEC requirements and the facility's power infrastructure standards. De-energize the upstream circuit breaker before making any connections to the PDU input. Verify that the circuit supplying this unit is rated to support the 30-amp load before energizing. Do not exceed the rated amperage of the unit or of individual outlet groups.

Technical Specifications
Input Current Rating
30 amps
C13 Outlet Count
30
C19 Outlet Count
6
Metering
Yes, current metering
Form Factor
Rackmount
Unit of Measure
Each
Brand
PANDUIT
Manufacturer Part Number
P36F16M