PANDUIT Panduit P24E30M-BL2A Vertical Pdu 18 C13 6 C19

Panduit P24E30M-BL2A Vertical Pdu 18 C13 6 C19

Brand: PANDUIT
SKU: P24E30M-BL2A
Availability: In Stock

Ships same day if ordered by 12 pm

$5,120.57
$5,120.57
HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The PANDUIT P24E30M-BL2A is a vertical rack-mount power distribution unit (PDU) designed for data center and server room power management. It provides 18 IEC C13 outlets and 6 IEC C19 outlets for a combined 24-outlet capacity, supporting a range of IT equipment from standard 1U servers to high-draw devices such as blade chassis and storage arrays. The monitored design allows facility and IT staff to track power consumption at the unit level, supporting load balancing and capacity planning. Licensed electricians and data center technicians are the primary installers.

This PDU is suited for vertical mounting in standard 2-post or 4-post open-frame racks and enclosed cabinets. The mix of C13 and C19 receptacles accommodates diverse equipment power cords, making it appropriate for mixed-load rack deployments in enterprise data centers, colocation facilities, and network equipment rooms. The monitored functionality provides real-time power data useful for energy audits and infrastructure management.

Key Features

  • 18 IEC C13 outlets support standard server and networking device power cords
  • 6 IEC C19 outlets accommodate high-current devices such as blade servers and PDU-fed UPS loads
  • Monitored unit-level power tracking supports load balancing and capacity planning
  • Vertical form factor maximizes outlet density within the rack footprint
  • Unit of measure: each (1 PDU per unit)

Compatibility

Designed as an OEM-style vertical rack PDU for use in standard 2-post and 4-post equipment racks accepting IEC C14 and IEC C20 power cord connections.

Installation Notes

Installation should be performed by a licensed electrician or qualified data center technician in accordance with applicable NEC requirements. De-energize the circuit and verify input voltage and amperage ratings match the facility branch circuit before connecting. Secure the PDU to the rack using the manufacturer-supplied mounting hardware before energizing. Do not exceed the rated load capacity across the outlet bank.

Technical Specifications
Outlet Configuration
18 x IEC C13, 6 x IEC C19
Total Outlets
24
Monitoring
Monitored
Mounting Orientation
Vertical
Unit of Measure
Each
Quantity Per Unit
1
Brand
PANDUIT
Manufacturer Part Number
P24E30M-BL2A
PANDUIT Panduit P24E30M-BL2A Vertical Pdu 18 C13 6 C19

Vendor: PANDUIT

Panduit P24E30M-BL2A Vertical Pdu 18 C13 6 C19

$5,120.57

Vendor: PANDUIT

Panduit P24E30M-BL2A Vertical Pdu 18 C13 6 C19

$5,120.57