Product Description

The NAPCO GEM-P9600 Gemini P9600 Security Panel is a multi-tasking hybrid security control panel suitable for security applications and home automation. It supports up to 96 users and offers 8 to 96 hardwired or wireless zones, including eight 2-wire fire zones. The system features automatic arming/disarming and three relay outputs, expandable to 96.

  • Supports 8 to 96 hardwire zones/points including 8 2-wire fire zones.
  • Offers up to eight independent area partitions and supports up to 96 users, 15 keypads and 800 logged events.
  • Allows permanent panel connection to home automation hubs using the GEM-RS232 interface.

Product Highlights

The Gemini P9600 is designed for ease of programming and use, with advanced compatibility features and is built for security professionals.

Product Information

Standard Information

  • Brand: NAPCO
  • Manufacturer Part Number: GEM-P9600
  • Country of Origin: Dominican Republic
Technical Specifications
Type
Home Automation and Security Controllers
Zones
8 TO 63
Item
Control Panel
Auto Arm
Yes
Auto Disarm
Yes
Input Power
16.5VAC
Max. Number Areas
8.0
Max. Number Zones
96.0
Max. Number Outputs
6.0
Max. Number Event Logs
800.0
Max. Number User Codes
96.0
Max. Number Event Schedules
255.0
Max. Number Wireless Points
96.0
Max. Number Wireless Keyfobs
16.0
Number of Wireless Receivers Supported
4.0
User Codes
Up to 96
Areas
Up to 8
Relay Outputs
3 on-board, expandable to 96
Programmable Lug
1 on-board
RF Receivers
Up to 4
Keypads
Up to 15
X-10 Devices
Up to 64
Event Log
800 event log
Scheduler
255 event scheduler
Control Panel
8 End-of-line-resistor burglary zones programmable for area, exit/entry delay, interior, follower, day zone, chime, fire option, sensor watch, swinger shutdown, zone anding and a variety of other features
Fire Zones
Including up to 8 2-wire fire zones
Users
Up to 96 individually coded users, each with a programmable authority level
Panel-Port
Exclusive RS232 panel-port supports PC home automation/ networking integration for 9600 baud comprehensive communications
Keypad Panics
Three keypad panics: fire, police and auxiliary
Area Partitions
Up to 8 independent area partitions
Access Stations
Up to 8 separate access stations by up to 96 users
Keypad
English-language prompts and system status messages from choice of keypad models
Zone Descriptions
User-customized zone descriptions, reprogrammable as required
Smoke Detectors
Supports 2-wire and 4-wire smoke detectors
Reporting
Reports alarms, restores and troubles by zone
Overview Mode
Overview mode permits monitoring and control of total system from one keypad
Guard-Tour
Guard-tour programmable for start time, tour length, and checkpoints (tour stations)
Entry Delay Times
2 Programmable entry delay times
Interior-Bypass Groups
2 Interior-bypass groups
Battery Test
Dynamic battery test interrupts charging and places battery under load every four hours
Chime
Chime by zone; programmable duration
Memory
Non-volatile RAM retains memory during power losses
Quickloader
Quickloader programmable
Auto-Download
Auto-download log
V.A.L.I.D. Feature
Exclusive V.A.L.I.D. feature (verifying automatic line integrity diagnostic) reduces false alarms due to changes in line resistance
Communicator
Compatible with all major receiver formats, including BFSK, 4/2, modem 2, SIA, 4/3/1, 4 + 2 express and point ID
Dial
Rotary dial and touchtone with rotary backup
Telephone Numbers
3 20-Digit telephone numbers
Reporting Options
Backup reporting; double reporting; split reporting
AC Failure Reporting
AC failure reporting with programmable report delay
Telephone Line
Supervised telephone line cut with programmable delay
Pager
Pager capability
SIA CP01
SIA CP01 compliant versions available
Operating temperature
32 to 120 degrees F (0 to 49 degrees C)
Loop voltage
10-13VAC
Loop current
2.5mA with 2.2ohm end-of-line resistor (model EOL2.2K); 5mA for 2-wire smoke detector zones
Loop resistance
300W max.; 50W for 2-wire smoke detector zones
Relay outputs (burglary; reset; aux)
wet, 12VDC, 1.2A max.; Dry (cut related jumper for dry contacts), SPDT contacts 24VDC, 2A, 0:6 PF
Auxiliary power output
12VDC regulated
Remote power output
12VDC regulated (for keypads), 750 mA combined standby current (remote power + aux. power + reset relay power)
Standby time
residential fire/burglary and commercial burglary, 4 hours minimum
EZM module
GEM-EZM8: input, 50mA (including PGM output) PGM output: 5mA, 12V special application
Keypad current
GEM-RP1CAE2: 100mA; 35mA if backlighting is disabled (cut W1, W2, W3)
PGM output
5mA, 12V special
Brand
Napco Security Systems
MPN
GEM-P9600
Model
GEM-P9600
Compatible Brand
Napco Security
Connectivity
N/A
NAPCO Napco GEM-P9600 Gemini P9600 Security Panel 8-96 Zones

Vendor: NAPCO

Napco GEM-P9600 Gemini P9600 Security Panel 8-96 Zones

$488.07

Vendor: NAPCO

Napco GEM-P9600 Gemini P9600 Security Panel 8-96 Zones

$488.07

Related Products

Customer Support Image

Need Support?

Call Jack and His Team