Leviton Telcom 8200-IGB Isolated Ground Receptacle

Brand: LEVITON
SKU: 8200-IGB
Availability: Out Of Stock
HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The LEVITON TELCOM 8200-IGB is an isolated ground, hospital grade duplex receptacle rated for NEMA 5-15R configurations. Isolated ground receptacles are designed to reduce electrical noise on sensitive equipment circuits by running a separate grounding conductor back to the panel without picking up noise from conduit or other ground paths. Hospital grade units meet the heightened durability and safety standards required for patient care environments. Licensed electricians install this receptacle in locations where electronic equipment performance depends on a clean ground reference.

This receptacle is suited for use in hospitals, medical offices, laboratories, and other commercial or institutional settings where sensitive electronic or diagnostic equipment requires isolated grounding. The NEMA 5-15R rating covers standard 15-amp, 125-volt, two-pole, three-wire grounding applications. It is appropriate for both new construction wiring and retrofit installations in existing patient care or critical equipment rooms.

Key Features

  • Isolated ground design reduces electrical noise interference on sensitive equipment circuits
  • Hospital grade construction meets elevated durability and safety requirements for medical environments
  • NEMA 5-15R configuration for 15-amp, 125-volt, two-pole, three-wire grounding circuits
  • Sold individually as a single unit (each)

Compatibility

Designed as an OEM-style replacement or new-installation isolated ground hospital grade receptacle for standard NEMA 5-15R branch circuit applications in medical and institutional facilities.

Installation Notes

Installation must be performed by a licensed electrician in accordance with the National Electrical Code (NEC) and all applicable local codes. De-energize the branch circuit at the panel and verify absence of voltage with a meter before beginning work. The isolated ground conductor must be routed separately back to the panel ground bus and must not be bonded to the equipment grounding conductor in the box. Hospital grade receptacles in patient care areas are subject to additional inspection and testing requirements under NFPA 99.

Technical Specifications
NEMA Configuration
5-15R
Grade
Hospital Grade
Grounding Type
Isolated Ground
Unit of Measure
Each
Quantity Per Unit
1
Brand
LEVITON TELCOM
Manufacturer Part Number
8200-IGB