Kidde - Edwards K-278B-1120 Break Glass Pull Station

SKU: K-278B-1120
Availability: In Stock

Ships same day if ordered by 12 pm

$98.03
$98.03
HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The KIDDE - EDWARDS K-278B-1120 is a single-action, break-glass pull station designed for use in fire alarm systems. When activated, the user breaks the glass element to trigger the alarm circuit, providing a clear, tamper-evident indication of manual activation. The terminal-style wiring connections allow for straightforward integration into conventional fire alarm control panel circuits. This pull station is installed by licensed fire alarm technicians and low-voltage electricians in commercial and institutional buildings requiring code-compliant manual initiation devices.

The K-278B-1120 is suited for manual fire alarm initiation in commercial, institutional, and light industrial environments. It is typically mounted at exit points, corridors, and stairwells in accordance with NFPA 72 requirements for manual pull station placement. The break-glass design provides a visual tamper indicator, making post-event inspection straightforward for AHJ review and system reset procedures.

Key Features

  • Single-action break-glass activation — no pull handle required, glass element breaks to trigger alarm
  • Terminal-style wiring connections for direct integration with fire alarm control panel wiring
  • Tamper-evident design — broken glass provides visible confirmation of activation
  • Compact form factor suitable for standard surface or flush mounting at code-required heights
  • Sold individually (unit of measure: each)

Compatibility

Designed as an OEM-style manual initiation device compatible with conventional fire alarm control panel circuits requiring a terminal-connected, single-action pull station.

Installation Notes

Installation must be performed by a licensed fire alarm technician or qualified low-voltage electrician in accordance with NFPA 72 and applicable local codes. De-energize the fire alarm control panel circuit before making wiring connections at the terminal block. Mount the pull station at the height specified by NFPA 72 and the local AHJ, typically 42 to 48 inches above finished floor. After installation, perform a full system functional test before returning the panel to service.

Technical Specifications
Activation Type
Single action, break glass
Wiring Connection
Terminal
Unit of Measure
Each
Quantity Per
1
Category
Pull Stations
Brand
KIDDE - EDWARDS
Manufacturer Part Number
K-278B-1120
EDWARDS SIGNALING Kidde - Edwards K-278B-1120 Break Glass Pull Station

Vendor: EDWARDS SIGNALING

Kidde - Edwards K-278B-1120 Break Glass Pull Station

$98.03

Vendor: EDWARDS SIGNALING

Kidde - Edwards K-278B-1120 Break Glass Pull Station

$98.03

Related Products

Customer Support Image

Need Support?

Call Jack and His Team