

Manufacturer pricing rules prevent us from advertising our discount — no account or email required to see it.
This product weighs 60 lb each and will be shipped via LTL carrier. A lift gate option will be added free of charge for your convenience.
Secure Payments
Easy Returns
Expert Advice
Fast Shipping
The GREE OWC12HP230V1R32AH is a one-way ceiling cassette indoor unit designed for ductless mini split systems operating on R32 refrigerant at 230 volts. Rated at 12,000 BTU/h, this unit pairs with a compatible GREE All Match outdoor unit to deliver directional airflow from a flush ceiling-mounted position. A brushless DC motor drives the cross-flow fan, supporting DC inverter-driven variable-capacity operation across a heating range down to -22 degrees F ambient and a cooling range down to -20 degrees F ambient. The unit includes a built-in condensate pump and an R32 gas sensor. Licensed HVAC technicians handle installation and commissioning.
This cassette is suited for single-zone residential and light commercial applications where ceiling-mounted, directional airflow is required — narrow rooms, corridors, retail spaces, and similar layouts. The one-way discharge pattern concentrates airflow along a defined axis, making it effective in elongated spaces where a four-way cassette would waste conditioned air. The unit is part of GREE's All Match R32 single-zone lineup and is intended to be matched with a compatible GREE R32 outdoor condensing unit. Cooling capacity ranges from 3,070 to 14,600 BTU/h; heating capacity ranges from 3,070 to 16,000 BTU/h at rated conditions.
Designed for use as the indoor air handler in GREE All Match single-zone R32 mini split systems operating at 230 volts. Must be matched with a compatible GREE R32 outdoor unit; consult GREE system pairing documentation to confirm the correct outdoor unit before ordering. AHRI Certificate 214810380 applies to verified system combinations.
Installation must be performed by an EPA Section 608-certified HVAC technician familiar with R32 flammable refrigerant handling procedures and local mechanical codes. Before any service or wiring work, shut off power at the disconnect and verify zero voltage at the unit. R32 is an A2L mildly flammable refrigerant — follow manufacturer safety guidelines and applicable local codes regarding ventilation and ignition source control during line set connection and leak testing. Secure the cassette mounting plate to ceiling structure capable of supporting the unit weight, verify the condensate pump operation after startup, and confirm airflow direction aligns with the room layout before closing the ceiling opening.
Thanks for subscribing!
This email has been registered!