The GREE LIV24HP230V1R32AH is the indoor air handler component of the Livo single-zone wall mount mini split heat pump system, operating on 230V with R32 refrigerant. This unit delivers 24,000 BTU/h of both cooling and heating capacity using high-efficiency DC inverter technology, which modulates compressor speed to match the load and hold precise setpoints without constant cycling. The air handler mounts on an interior wall and connects to a compatible GREE Livo outdoor condensing unit. It is installed by licensed HVAC technicians in residential and light commercial single-zone applications requiring ductless climate control.
The LIV24HP230V1R32AH is suited for single-zone residential and light commercial spaces where ducted systems are impractical or unavailable. The unit supports low ambient cooling operation down to 0 degrees F and low ambient heating operation down to -13 degrees F, making it viable in cold climates year-round. It ships as the indoor wall mount head only and pairs with the GREE LIV24HP230V1R32AO outdoor unit to form a complete system. Wi-Fi connectivity is included, and wired controller options are supported for installations that require hard-wired control rather than the included wireless remote with LCD display.
This indoor air handler is designed for use as a matched single-zone system with the GREE LIV24HP230V1R32AO outdoor condensing unit. AHRI Certificate 214779349 applies to this matched system. Do not pair with outdoor units outside the Livo R32 single-zone product family without verifying compatibility through GREE engineering documentation.
Installation must be performed by a licensed HVAC technician holding the appropriate EPA Section 608 certification for handling R32 refrigerant. Power down the circuit at the breaker before any wiring work, and verify voltage at the disconnect before connecting the line set and control wiring. The wall mount bracket must be secured to structural framing capable of supporting the unit weight, and the refrigerant line set must be leak-tested and evacuated before charging. Consult GREE installation documentation and applicable local mechanical codes before commissioning.