


Ships via freight in 1-3 business days
Manufacturer pricing rules prevent us from advertising our discount — no account or email required to see it.
This product weighs 163 lb each and will be shipped via LTL carrier. A lift gate option will be added free of charge for your convenience.
Secure Payments
Easy Returns
Expert Advice
Fast Shipping
The Goodman axv6ss4210 is a 3.5-ton, 16.2 SEER2 inverter-driven outdoor split air conditioner designed for residential and multi-family cooling applications. Part of the Amana AXV6SS series, this side-discharge unit operates on R-32 refrigerant and delivers 41,000 BTU/h of rated cooling capacity. The variable-speed inverter compressor allows the unit to modulate output to match load, reducing short-cycling and improving runtime efficiency. Rated at 208/230 volts, single-phase, 60 Hz with a minimum circuit ampacity of 31.8 amps, this unit is installed by licensed HVAC contractors and is compatible with the Amana Brand smart thermostat for communicating-system configurations.
The axv6ss4210 is suited for residential and multi-family installations in both Southeast and North DOE regional compliance zones. The side-discharge airflow pattern fits installations where top-discharge clearances are restricted. Operating across a wide ambient range of 0 degrees F to 115 degrees F, this unit handles extreme seasonal conditions without lockout. The unit ships factory pre-charged with 100 oz of R-32 refrigerant for a standard 15-foot line set, with maximum line set lengths of 100 feet horizontal and 90 feet vertical. Compatible components referenced by the manufacturer include product references 130-DK-008, DACA-WB-3, and KPW5G112.
Designed for use within the Amana AXV6SS series split-system platform. Manufacturer-referenced compatible components include 130-DK-008, DACA-WB-3, and KPW5G112. Communication feature requires Amana Brand smart thermostat. Verify indoor unit compatibility and refrigerant circuit design before installation.
Installation must be performed by a licensed HVAC technician holding EPA Section 608 certification for R-32 refrigerant handling. Disconnect and lock out all electrical power before making any electrical or refrigerant connections. Maximum overcurrent protection is 35 amps; verify that the disconnect and branch-circuit breaker are sized accordingly per NEC requirements. Do not exceed the manufacturer-specified maximum line set lengths, and confirm adequate clearances for the side-discharge airflow path before mounting the unit.
Thanks for subscribing!
This email has been registered!
