

Ships via freight in 1-3 business days
Manufacturer pricing rules prevent us from advertising our discount — no account or email required to see it.
This product weighs 168 lb each and will be shipped via LTL carrier. A lift gate option will be added free of charge for your convenience.
Secure Payments
Easy Returns
Expert Advice
Fast Shipping
The GOODMAN aszs604810 is a 4-ton, single-phase, inverter-driven split heat pump outdoor unit rated at 16.2 SEER2 and 8.1 HSPF2. It delivers 45,000 BTU/h of rated cooling capacity and 45,500 BTU/h of rated heating capacity using R-410A refrigerant. The side-discharge configuration and multi-speed inverter compressor allow the unit to modulate output across a wide operating range, from -10 degrees F up to 70 degrees F on the heating side and down to 0 degrees F on the cooling side. Installation is ducted and requires a licensed HVAC technician. The unit includes communication capability compatible with the Amana Brand smart thermostat, enabling advanced system integration and diagnostics.
The aszs604810 is designed for ducted residential and light commercial applications where inverter technology is required to meet regional efficiency standards. It carries DOE regional compliance across all climate zones. The side-discharge layout suits installations where vertical airflow is not practical, such as tight equipment yards or side-yard setbacks. The unit ships pre-charged with 118 oz of R-410A refrigerant, supporting a standard line set run of up to 100 ft horizontal or 90 ft vertical, with a 3/8-inch liquid line and a 7/8-inch suction line O.D. The unit was manufactured in Thailand and is part of the Amana ASZS6 series.
The aszs604810 is part of the Amana ASZS6 series and is designed for use with compatible ducted split-system indoor coil and air handler combinations. Referenced component accessories include 130-DK-006, 130-DK-008, ATST-CWE-BL-A, DACA-WB-3, KEH3P573567, KPS00601, KPS00602, KPS00603, KPS00604, KPW5G112, and TXV-FX-KX-5T. Consult the manufacturer matchup tool or ARI-certified system matchup data to confirm approved indoor unit pairings before installation.
Installation must be performed by a licensed HVAC technician in accordance with local mechanical codes and the manufacturer installation instructions. Disconnect and lock out all electrical power at the disconnect box before servicing or making electrical connections. Minimum circuit ampacity is 34.4 A and maximum overcurrent protection is 35 A; verify that the supply circuit is properly sized before startup. Do not exceed the rated maximum line set lengths or deviate from the specified pipe sizes, as doing so may affect refrigerant charge balance and system performance.
Thanks for subscribing!
This email has been registered!