The GOODMAN arvt800804cn is an 80 AFUE two-stage, variable-speed ECM upflow/horizontal gas furnace rated at 80,000 BTU/h high-fire input and 64,000 BTU/h high-fire output. It runs a 56,000 BTU/h low-fire input stage for quieter, more efficient part-load operation. The variable-speed blower motor delivers airflow from 1,090 to 1,400 cubic feet per minute across heating stages, reducing temperature swings and improving comfort. Powered at 115 volts, 60 Hz, single phase, the unit draws a minimum of 7.75 amps with a 15-amp maximum overcurrent protection rating. Licensed HVAC technicians perform installation in residential and light-commercial applications.
This furnace is configured for upflow or horizontal installation, making it suitable for basement, closet, attic, or crawlspace applications where the air handler sits above or alongside the living space. The two-stage gas valve reduces input to 56,000 BTU/h on low fire, cutting cycling and noise during mild weather. The non-NOx burner design meets low-emissions requirements in regulated markets. With a nominal cooling capacity pairing of 48,000 BTU/h (4 tons), this unit is sized to match a 4-ton cooling coil in a split system. The communication feature allows integration with compatible communicating thermostats and controls.
Designed as an OEM upflow/horizontal gas furnace for pairing with a 4-ton (48,000 BTU/h nominal) cooling coil in a split-system configuration. Specific compatible coil and air handler model numbers were not provided in the product data; consult the manufacturer documentation to confirm matched-system pairings.
Installation must be performed by a licensed HVAC technician in accordance with local mechanical codes, the National Fuel Gas Code (NFPA 54/ANSI Z223.1), and the manufacturer installation instructions. Shut off gas supply and disconnect electrical power before servicing or connecting the unit. Maintain a minimum 1-foot clearance to combustible materials on all applicable sides as specified. The 4-inch vent diameter connection requires a properly sized venting system; verify vent material compatibility and local code requirements before installation.