

Ships via freight in 1-3 business days
Manufacturer pricing rules prevent us from advertising our discount — no account or email required to see it.
This product weighs 107 lb each and will be shipped via LTL carrier. A lift gate option will be added free of charge for your convenience.
Secure Payments
Easy Returns
Expert Advice
Fast Shipping
The GOODMAN ar9t800603bn is an 80 AFUE two-stage gas furnace built for upflow and horizontal ducted installations. Rated at 60,000 BTU/h high-fire input with a 48,000 BTU/h high-fire output, this unit operates at 80 percent annual fuel utilization efficiency. It uses a multi-speed ECM blower motor running at 115 volts, 60 Hz, single phase, drawing a minimum of 8.7 amps. The two-stage gas valve enables a low-fire input of 42,000 BTU/h, reducing temperature swings and improving comfort in variable-load conditions. Licensed HVAC technicians install this furnace as a central heating system component in ducted residential and light commercial applications.
This furnace is designed for upflow or horizontal ducted installations where a nominal 3-ton cooling coil is paired downstream. The unit cabinet measures 17.5 inches wide, 28 inches deep, and 33.375 inches tall, fitting standard 17.5-inch air handler openings. The Non-NOx burner configuration meets low-emissions requirements in applicable jurisdictions. A 10-inch by 8-inch blower assembly delivers up to 1,412.5 cubic feet per minute of airflow at high heat, supporting balanced airflow across typical residential duct systems.
Designed for upflow and horizontal ducted gas furnace installations with a nominal 3-ton cooling capacity. Cabinet width of 17.5 inches is compatible with standard coil cabinets and air handler platforms sized for that dimension. Specific compatible coil and air handler model numbers should be confirmed against the current Goodman or Amana product matching guides before installation.
Installation must be performed by a licensed HVAC technician in accordance with local mechanical codes, the National Fuel Gas Code (NFPA 54), and the manufacturer installation instructions. Shut off gas supply and disconnect electrical power at the breaker before any service or connection work. Maximum overcurrent protection is 15 amps; verify the branch circuit is correctly sized before energizing. Do not exceed the published temperature rise range, and confirm duct static pressure is within design limits before commissioning.
Thanks for subscribing!
This email has been registered!