The Goodman alxs3nn4810 is a single-stage, R-32 refrigerant outdoor condensing unit rated at 13.4 SEER2 and 48,000 BTU/h nominal cooling capacity. Built on the Amana ALXS3N series platform, this non-communicating unit operates on 208/230 volts single phase at 60 Hz and uses a scroll compressor with top-discharge airflow. At 188 pounds and a footprint of 29 inches wide by 29 inches deep by 39.5 inches tall, it is sized for residential and light-commercial applications in DOE North regional compliance zones. Licensed HVAC technicians perform installation and commissioning.
This unit is intended for split-system cooling-only applications in DOE North regional markets. It pairs with a compatible indoor air handler or coil to form a complete split system. The unit operates over a standard ambient cooling range of 55 degrees F to 115 degrees F. Typical installations are new construction or replacement projects in residential or multi-family settings where a non-communicating, single-stage outdoor unit is specified. The factory refrigerant charge of 84 ounces of R-32 supports a pre-charged line length of 15 feet, with a maximum standard line set of 200 feet and a maximum vertical run of 79 feet.
Designed for use in DOE North regional split cooling-only systems requiring a non-communicating, single-stage outdoor unit. Compatible accessory and component references listed in supplier data include 0130R00000S, ABK-20, ASC01A, CSR-U-1, FSK01A, LAKT01, and LSK02A. Confirm indoor coil or air handler compatibility and regional DOE compliance before installation.
Installation must be performed by a licensed HVAC technician holding an EPA Section 608 certification, as R-32 is a mildly flammable A2L refrigerant requiring appropriate handling procedures and tools. Disconnect and lock out all electrical power before making any connections or servicing the unit. Liquid line connection is 3/8 inch O.D. and suction line connection is 1-1/8 inch O.D.; verify line set sizing against manufacturer tables for runs beyond the pre-charged 15-foot length, adding 0.58 pounds per foot of additional line. Follow all applicable local mechanical and electrical codes, including NEC requirements for minimum circuit ampacity of 25.6 amps and maximum overcurrent protection of 40 amps.