SOUTHWIRE Genesis Cable 43201004 Fplr Fire Alarm Cable 12/2 1000 Ft Red

Genesis Cable 43201004 Fplr Fire Alarm Cable 12/2 1000 Ft Red

SOUTHWIRE
Brand: SOUTHWIRE
SKU: 43201004
Availability: In Stock

Ships same day if ordered by 12 pm

$1,438.37
$1,438.37
HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The GENESIS CABLE 43201004 is a 12 AWG 2-conductor unshielded solid fire alarm cable rated FPLR (Riser) and supplied on a 1000-foot roll in red jacket. FPLR-rated cable is listed for use in riser applications where the cable passes between floors through penetrations and vertical runs inside a building. The solid conductor construction delivers reliable, low-resistance signal paths for fire alarm initiating circuits and notification appliance circuits. Licensed fire alarm installers and low-voltage electricians specify this cable for new construction and retrofit fire alarm system wiring where a riser-rated, unshielded solid conductor product is required by the system design and local AHJ.

This cable is used in commercial and residential fire alarm systems where FPLR-rated wiring is required by NFPA 72 and local fire codes. Typical applications include connecting smoke detectors, pull stations, horn-strobes, and control panel zones in multi-story buildings. The red jacket color is the industry-standard identifier for fire alarm circuit wiring, aiding inspection and code compliance. Electricians and fire alarm technicians use this product during rough-in and trim-out phases of construction and renovation projects requiring riser-rated fire alarm wiring.

Key Features

  • FPLR (Riser) rating listed for vertical runs and floor-to-floor riser applications per NFPA 72 requirements
  • 12 AWG solid conductor construction for consistent conductivity across long circuit runs
  • 2-conductor unshielded configuration suitable for Class B initiating device circuits and notification appliance circuits
  • Red jacket provides instant visual identification as fire alarm circuit wiring during inspection
  • 1000-foot roll quantity supports large commercial or multi-unit residential installations from a single spool

Compatibility

Designed as an OEM-style riser-rated fire alarm cable for use with conventional and addressable fire alarm control panels requiring 12 AWG 2-conductor unshielded solid FPLR wiring on initiating device circuits or notification appliance circuits.

Installation Notes

Installation must be performed by a licensed fire alarm technician or electrician in accordance with NFPA 72, NFPA 70 (NEC Article 760), and all applicable local codes. De-energize the fire alarm control panel and notify the monitoring center before making any circuit connections. Maintain minimum bend radii when routing through conduit or open plenum to avoid conductor damage. All penetrations through fire-rated assemblies must be properly firestopped per the project specifications and local AHJ requirements.

Technical Specifications
Conductor Size
12 AWG
Number of Conductors
2
Conductor Type
Solid (Stranded per label notation; verify datasheet)
Cable Rating
FPLR (Riser)
Shielding
Unshielded
Jacket Color
Red
Roll Length
1000 feet
Category
Fire Unshielded Solid
Unit of Measure
Each (1 roll per unit)
Brand
GENESIS CABLE
Manufacturer Part Number
43201004
SOUTHWIRE Genesis Cable 43201004 Fplr Fire Alarm Cable 12/2 1000 Ft Red