

Ships same day if ordered by 12 pm
Manufacturer pricing rules prevent us from advertising our discount — no account or email required to see it.
Secure Payments
Easy Returns
Expert Advice
Fast Shipping
The EMBERGLOW EWPO2430PV is a millivolt-ignition, vent-free burner system designed for liquid propane (LP) operation in indoor, vent-free fireboxes. Rated at a maximum of 39,000 BTU/h, it delivers high-output radiant heat without requiring a flue or dedicated venting. The millivolt control circuit allows manual operation directly at the burner and supports optional remote-control accessories, though no remote is included. An Oxygen Depletion System (ODS) monitors room oxygen levels and automatically shuts off the gas supply if levels fall below a safe threshold. Installation is approved for mobile homes. This burner is intended for professional installation by a licensed gas technician.
This burner is rated for use with 18-inch, 24-inch, and 30-inch Everwarm Palmetto and Low Country Timber log sets inside a vent-free firebox. Minimum firebox requirements vary by log size: an 18-inch log set requires a firebox at least 17 inches tall, 13.5 inches deep, 24 inches wide at the front, and 20.5 inches wide at the rear. A 24-inch log set requires the same height and depth with a 28-inch front width and 20.5-inch rear width. A 30-inch log set requires the same height and depth with a 32-inch front width and 26-inch rear width. Due to maximum BTU output, this burner cannot be used in the following Monessen fireboxes: ACUF32-BD, ACUF32-GD, BUF32A, BUF32-T, BUF32-H, LCUF32CR-C, LCUF32CR-BT, LCUF32CR-GT, or LCUF32CR-GH.
Certified for use with Everwarm Palmetto and Low Country Timber log sets in 18-inch, 24-inch, and 30-inch sizes only. Burners are not universal — use with non-certified log sets creates serious risk of fire, carbon monoxide poisoning, and property damage. This burner cannot be installed in the following Monessen fireboxes: ACUF32-BD, ACUF32-GD, BUF32A, BUF32-T, BUF32-H, LCUF32CR-C, LCUF32CR-BT, LCUF32CR-GT, or LCUF32CR-GH. This product cannot be shipped to California. State and local codes in some jurisdictions prohibit vent-free products — verify local building codes before installation.
Installation must be performed by a licensed gas technician in accordance with applicable local codes and the National Fuel Gas Code (NFPA 54). Shut off the LP supply at the tank or meter before making any gas connections. Verify manifold and inlet supply pressures against the specifications below using a manometer before commissioning the burner. Vent-free appliances require adequate room volume and air exchange per manufacturer and code requirements — do not install in sealed or undersized spaces.
Thanks for subscribing!
This email has been registered!