The CPS PRODUCTS LS790B Leak-Seeker combines advanced microcomputer circuitry with Ion-pump sensor technology for highly sensitive and accurate refrigerant leak detection. It features over 100 computer-generated tones and a high-intensity bar graph display. The detector is individually calibrated to detect a leak rate of better than 0.25 oz/yr (7g/yr) of HFC and can detect all non-combustible CFC, HCFC, HFC gases and blends.
Key Features
Individually calibrated to detect a leak rate of better than 0.25 oz/yr (7g/yr) of HFC
Patented Ion-Pump sensor technology proven effective in detecting all refrigerant types
Patented water vapor filter provides greater stability under high humidity conditions
Patented automatic calibration, user-selectable sensitivity ranges, and a lock-out mode for locating leaks in contaminated zones
Auto-off function
Technical Specifications
Detector Type
Proprietary Ion-Pump sensor with built-in selective filter housing
Sensitivity
Better than 0.25 oz (7g) / year leak rate of HFC
Sensitivity Selection
Manual
Refrigerant Sensitivity
All, including those with hydrocarbon components (CFC, HCFC, HFC, HFO, NH3, HC)
Visual Alarm
High intensity LED (Varies in brightness); High intensity bar graph display
Flex Probe
18 inch long metal flex probe
Operating Temperature
0 to 140 degrees F (-18 to 60 degrees C)
Controls
6 button keypad
Power (Battery Life)
(4) AA alkaline batteries (>40 hr continuous use)
Audible Alarms
128 computer generated tones to precisely guide user to the source of the leak