Product Description

The COOPER BUSSMANN BP/FRN-R-30ID is a 30-amp, 250-volt indicating fuse rated for Class RK5 service. It uses a dual-element, time-delay design that tolerates motor inrush current while still providing current-limiting protection against sustained overloads and short circuits. A key field feature is the indicating label: if the fuse opens, the label darkens, giving technicians a fast visual confirmation of fuse status without removing the fuse or using a meter. This pack contains two fuses and is suitable for use by licensed electricians and qualified maintenance personnel working on commercial and industrial electrical systems.

These fuses are suited for AC power distribution applications including service mains, feeders, and branch circuits. The dual-element time-delay characteristic makes them appropriate for motor branch circuits where inrush current would nuisance-trip a standard fuse. They also serve transformer and other inductive load circuits, as well as lighting and heating loads. The carded two-pack format is intended for service and replacement work where a spare on hand is standard practice.

Key Features

  • Indicating label darkens visually when fuse has opened — no meter required for quick status check
  • Dual-element, time-delay construction tolerates motor inrush without sacrificing short-circuit protection
  • Current-limiting Class RK5 rating provides downstream component protection during fault events
  • Rated 30 amps at 250 volts for AC power distribution service
  • UL Listed
  • Sold as a two-pack on a card for convenient replacement inventory

Compatibility

Designed for use in AC power distribution system mains, feeders, branch circuits, motor branch circuits, transformer and inductive load circuits, and lighting and heating non-inductive load circuits requiring a Class RK5 time-delay fuse rated 30A at 250V.

Installation Notes

Installation and replacement of current-limiting fuses must be performed by a licensed electrician in accordance with the National Electrical Code (NEC) and all applicable local codes. De-energize and lock out the circuit at the disconnect or panel before handling any fuse or fuseholder. Verify the replacement fuse ampere rating, voltage rating, and class match the fuseholder and circuit requirements before installing. Never substitute a higher-ampere or different-class fuse to restore service.

Technical Specifications
Ampere Rating
30A
Voltage Rating
250V
Fuse Class
RK5
Fuse Type
Dual Element, Time Delay, Current Limiting, Indicating
Package Quantity
2 fuses per pack
Dimensions
2.375 inches L x 1.375 inches W x 0.25 inches H
Weight
1.3 pounds
Certifications
UL Listed
Packaging
Carded
Brand
COOPER BUSSMANN
Manufacturer Part Number
BP/FRN-R-30ID
BUSSMANN Cooper Bussmann BP/FRN-R-30ID 30A 250V Class RK5 Indicating Fuse

Vendor: BUSSMANN

Cooper Bussmann BP/FRN-R-30ID 30A 250V Class RK5 Indicating Fuse

$124.94

Vendor: BUSSMANN

Cooper Bussmann BP/FRN-R-30ID 30A 250V Class RK5 Indicating Fuse

$124.94

Related Products

Customer Support Image

Need Support?

Call Jack and His Team