

Ships via freight in 1-3 business days
Manufacturer pricing rules prevent us from advertising our discount — no account or email required to see it.
This product weighs 40 lb each and will be shipped via LTL carrier. A lift gate option will be added free of charge for your convenience.
Secure Payments
Easy Returns
Expert Advice
Fast Shipping
The Bravo BRV-M18CT-230VI is an 18,000 BTU ceiling cassette indoor unit designed for ductless mini split heat pump systems operating on 208/230 volts, single-phase, 60 Hz power. Built for multi-zone configurations, this cassette mounts flush in the ceiling to deliver consistent, 360-degree airflow distribution across the conditioned space. The unit uses R32 refrigerant, which carries a lower global warming potential than older refrigerant blends. With a maximum indoor airflow of 442 CFM and an indoor noise level rated at 45 dB(A), it suits commercial and residential spaces where both comfort and quiet operation matter. A licensed HVAC technician performs installation.
The BRV-M18CT-230VI is intended for use as an indoor air handler in multi-zone ductless mini split systems. Its ceiling cassette form factor makes it well suited for open-plan commercial spaces, retail environments, offices, and larger residential rooms where wall-mount or floor-mount units are not practical. The unit pairs with compatible Bravo Milano multi-zone outdoor condensers. Documented system configurations include 2-zone setups at 30,000 BTU and 42,000 BTU outdoor capacity, as well as 3-zone setups at 42,000 BTU outdoor capacity, each using multiple BRV-M18CT-230VI indoor units.
The BRV-M18CT-230VI is a Milano Series ceiling cassette indoor unit confirmed for use in Bravo multi-zone ductless mini split systems. Documented configurations include 2-zone 30,000 BTU, 2-zone 42,000 BTU, and 3-zone 42,000 BTU outdoor capacity pairings using this indoor unit model.
Installation must be performed by a licensed HVAC technician in accordance with local mechanical codes and the manufacturer's installation manual. The ceiling structure must be capable of supporting the unit's weight, and adequate ceiling plenum clearance is required before mounting. Shut off all power to the circuit at the breaker panel before making any electrical connections, and recover or isolate refrigerant per EPA Section 608 requirements before servicing the refrigerant circuit. Do not exceed the maximum fuse rating of 5 amps for this indoor unit.
Thanks for subscribing!
This email has been registered!