BELDEN Belden Inc. 8725 0601000 Fire Shielded Cable 4PR 20AWG

Belden Inc. 8725 0601000 Fire Shielded Cable 4PR 20AWG

Brand: BELDEN
SKU: 8725 0601000
Availability: Out Of Stock
HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The BELDEN INC. 8725 0601000 is a fire shielded solid conductor cable designed for low-voltage signal and control wiring applications. This 4-pair, 20 AWG construction uses polypropylene (PP) insulation with a PVC jacket finished in chrome, providing reliable protection in installations where fire shielding is required by code. It is sold by the unit and is typically installed by licensed electricians and low-voltage systems technicians in commercial and light industrial environments.

This cable is suited for use in fire alarm, security, and control wiring systems where fire-rated or fire-shielded cable is specified. The solid conductor construction supports stable signal transmission over fixed runs in walls, conduit, and cable trays. Installers working on new construction or retrofit projects that require shielded cable per applicable codes will find this cable appropriate for those applications.

Key Features

  • Fire shielded construction meets shielded cable requirements for applicable low-voltage system installations
  • 4-pair configuration supports multiple signal or control circuits in a single run
  • 20 AWG solid conductors provide consistent impedance over fixed-route installations
  • Polypropylene insulation offers resistance to moisture and chemical exposure
  • PVC outer jacket in chrome finish provides durable mechanical protection

Compatibility

Designed as an OEM-style replacement or direct-use fire shielded solid cable for low-voltage control and signal wiring systems requiring a 4-pair, 20 AWG shielded cable configuration.

Installation Notes

Installation should be performed by a licensed electrician or qualified low-voltage technician in accordance with NEC Article 760 for fire alarm systems or other applicable local codes. De-energize all circuits before terminating conductors and verify that the cable routing complies with separation requirements from high-voltage wiring. Avoid sharp bends that exceed the cable minimum bend radius, and secure the cable at intervals per code requirements.

Technical Specifications
Number of Pairs
4
Conductor Gauge
20 AWG
Conductor Type
Solid
Insulation Material
Polypropylene (PP)
Jacket Material
PVC
Jacket Color
Chrome
Cable Category
Fire Shielded Solid
Unit of Measure
Each
Quantity Per Unit
1
Brand
BELDEN INC.
Manufacturer Part Number
8725 0601000

Related Products

Customer Support Image

Need Support?

Call Jack and His Team