Product Description

The American Standard AUHMD120ACV5VB is a Platinum 95 series gas furnace configured for upflow installations that provides fully modulating heating, variable-speed airflow, and converts up to 97% of fuel into heat. The unit communicates via the AccuLink system and offers a simplified Comfort Control connection. It includes a heavy steel insulated cabinet and Comfort-R humidity reduction for seasonal humidity management.

  • Fully modulating gas valve with 40% to 100% firing rates for precise temperature control
  • AccuLink communicating system and simplified Comfort Control connection with variable-speed fan for even, quiet air distribution
  • High-efficiency condensing design converting up to 97% of fuel into heat; dimensions 40 in x 24.5 in x 28 in

Product Highlights

Upflow condensing modulating gas furnace, 120,000 BTU input, nominal 5 ton capacity, 97% AFUE, AccuLink communicating, Comfort-R humidity reduction

Product Information

Standard Information

  • Brand: AMERICAN STANDARD
  • Manufacturer Part Number: AUHMD120ACV5VB

Technical Specifications

  • Brand: American Standard
  • Model: AUHMD120ACV5VB
  • Series: Platinum 95
  • Type: Condensing modulating gas furnace
  • Configuration: Upflow (multi-position: upflow/horizontal options supported)
  • BTU Input: 120,000 BTU/hr
  • BTU Output: 114,000 BTU/hr
  • Capacity: 5 Ton (nominal)
  • AFUE: 97%
  • Heating stages: Modulating (variable)
  • Firing range: 40% to 100%
  • Fuel Type: Natural gas
  • Motor Type: Variable speed motor
  • Motor Power: 1 HP (blower drive); 1/50 HP (combustion fan) -- (low confidence on combustion fan rating)
  • Number of Burners: 6
  • Voltage (Input Voltage): 115 VAC, 60 Hz (blower drive)
  • Combustion Fan Voltage: 115 VAC, 60 Hz (combustion fan)
  • Current Rating: 10 A FLA (blower drive); 1 A FLA (combustion fan); 15 A (MOP)
  • Ignition Type: Silicon nitride hot surface ignition
  • Vent Size: 3 in diameter (typical for PVC high-efficiency venting; moderate confidence)
  • Blower Dimension: 10 in diameter x 10 in width
  • Orientation: Upflow / Horizontal Left (multi-position)
  • Dimensions (H x W x D): 40 in x 24.5 in x 28 in
  • Applicable Standards / Certifications: ETL (Canada and US); ANSI Z21.47 / CSA 2.3
  • Communications: AccuLink communicating system (plug-and-play design)
  • Cabinet Material: Heavy steel insulated cabinet
  • Features: Variable-speed blower, low energy power venter, vent proving pressure switch, direct drive blower, modulating gas valve