Abb TL24415C Mlo Load Center 150A 24-circuit 3P4W

ABB
Brand: ABB
SKU: TL24415C
Availability: In Stock

Ships same day if ordered by 12 pm

%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E
$1,304.44
$1,304.44
HAVE A QUESTION?

Our team is ready to help!

  • Voomi Supply

    Secure Payments

  • Voomi Supply

    Easy Returns

  • Voomi Supply

    Expert Advice

  • Voomi Supply

    Fast Shipping

Product Description

The ABB TL24415C is a main lug only (MLO) load center rated for 150 amps with a 24-circuit capacity in a 3-phase, 4-wire configuration. MLO panels do not include an integrated main breaker, requiring a separately installed upstream disconnect. This load center is designed for use in commercial and light industrial electrical distribution systems where a main breaker is already present upstream. Licensed electricians install this type of panel as a sub-panel or branch distribution point in larger electrical systems.

This load center suits commercial sub-panel installations where 3-phase power distribution is required. The 3-phase, 4-wire (3P4W) configuration supports balanced load distribution across phases, making it appropriate for facilities with a mix of single-phase and three-phase branch circuits. The 24-circuit capacity allows for a dense distribution of branch circuit breakers within a single enclosure.

Key Features

  • Main lug only (MLO) design requires an upstream disconnect or main breaker
  • 150-amp main lug rating for high-capacity sub-panel applications
  • 24-circuit capacity for multi-branch distribution
  • 3-phase, 4-wire (3P4W) configuration supports single-phase and three-phase loads
  • Suitable for commercial and light industrial sub-panel installations

Compatibility

Designed as an OEM-style load center for 3-phase, 4-wire commercial electrical distribution systems requiring a main lug only sub-panel configuration.

Installation Notes

Installation must be performed by a licensed electrician in accordance with the National Electrical Code (NEC). De-energize the upstream feed and verify absence of voltage at all lugs before making any connections. MLO panels require a properly rated upstream disconnect or main breaker to be installed per NEC requirements. Verify conductor sizing and conduit fill comply with applicable local codes before energizing.

Technical Specifications

  • Amperage Rating: 150 amps
  • Number of Circuits: 24
  • Phase Configuration: 3-Phase, 4-Wire (3P4W)
  • Panel Type: Main Lug Only (MLO)
  • UPC: 78316418991

Standard Information

  • Brand: ABB
  • Manufacturer Part Number: TL24415C