{"product_id":"weidmuller-8965490000-act20x-hui-sao-s","title":"Weidmuller 8965490000 Act20x-hui-sao-s","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Weidmuller 8965490000 ACT20X-HUI-SAO-S transmits analog signals from hazardous areas safely galvanically separated into non or less hazardous areas. For this purpose the input circuits are designed intrinsically safe.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConfiguration and diagnosis via FDT\/DTM Software “WI-Manager”.\u003c\/li\u003e\n  \u003cli\u003eCan be mounted in the safe area and in zone 2 \/ division 2 and receive signals from zone 0, 1, 2, 20, 21 and 22, as well as Class I\/II\/III, division 1, group A-G.\u003c\/li\u003e\n  \u003cli\u003eActive or passive signal inputs for RTD, TC, potentiometer, V and mA are completely electrically isolated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe Weidmuller ACT20X-HUI-SAO-S is a signal isolating converter with intrinsically safe input circuits, designed for transmitting analog signals from hazardous to safe areas. It supports RTD, TC, potentiometer, voltage, and current inputs with 3-way galvanic isolation.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Weidmuller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 8965490000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersion\u003c\/strong\u003e: EX signal isolating converter, Ex-output: U, I, R,\t1, Safe-output: 4-20mA\/ relay, 1-channel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder No.\u003c\/strong\u003e: 8965490000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Status relay, 1 NC (voltage-free)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e: 4032248785100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 113.6 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth (inches)\u003c\/strong\u003e: 4.472 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 119.2 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight (inches)\u003c\/strong\u003e: 4.693 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 22.5 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth (inches)\u003c\/strong\u003e: 0.886 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet weight\u003c\/strong\u003e: 202 g\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage temperature\u003c\/strong\u003e: -20 °C...85 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: -20 °C...60 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 0...95 % (no condensation)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSIL in compliance with IEC 61508\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMTBF\u003c\/strong\u003e: 74 a\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status\u003c\/strong\u003e: Compliant with exemption\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Exemption (if applicable\/known)\u003c\/strong\u003e: 7a, 7cI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH SVHC\u003c\/strong\u003e: Lead 7439-92-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCIP\u003c\/strong\u003e: 2f6dd957-421a-46db-a0c2-cf1609156924\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting position\u003c\/strong\u003e: horizontal or vertical\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting rail\u003c\/strong\u003e: TS 35\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of mounting\u003c\/strong\u003e: Snap mounting support rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput current\u003c\/strong\u003e: 0...20 mA, 4...20 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput resistance\u003c\/strong\u003e: configurable, 0\t10 kΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput resistance, current\u003c\/strong\u003e: 20 Ω + PTC 50 Ω\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput resistance, voltage\u003c\/strong\u003e: \u0026gt; 10 MΩ @ 600 mV, 2 MΩ @ 28 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput voltage\u003c\/strong\u003e: configurable, 0\t1 V DC, 0,2\t1 V DC, 1\t5 V DC, 0...(5)10 V, 2\t10 V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLine resistance in measuring circuit\u003c\/strong\u003e: ≤ 50 Ω\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of inputs, Ex\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotentiometer\u003c\/strong\u003e: 10 Ω\t10 kΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor\u003c\/strong\u003e: 2-\/3-\/4-wire, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResistance\u003c\/strong\u003e: 0  - 12 kΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor supply\u003c\/strong\u003e: 21.4\t16.5 V DC \/ 0\t20 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature input range\u003c\/strong\u003e: Configurable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad resistance current\u003c\/strong\u003e: \u0026lt;600 Ω\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber analogue outputs\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput behaviour on failure downscale\u003c\/strong\u003e: 23 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput behaviour on failure upscale\u003c\/strong\u003e: 3.5 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput current\u003c\/strong\u003e: 4...20 mA, loop-powered, 0\/4...20 mA, 0(4)...20 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal output\u003c\/strong\u003e: direct or inverted\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType (analogue output)\u003c\/strong\u003e: 'active','connected control must be passive'\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlarm function\u003c\/strong\u003e: configurable, Limit values: high, low, window, Sensor error, No supply voltage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuous current\u003c\/strong\u003e: ≤ 0.5 A AC \/ 0.3 A DC (safe zone), ≤ 0,5 A AC \/ 1 A DC (zone 2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHysteresis\u003c\/strong\u003e: 0.1 mA (switching threshold)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal switching voltage\u003c\/strong\u003e: ≤ 125 V AC \/ 110 V DC (safe area), ≤ 32 V AC \/ 32 V DC (zone 2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of alarm outputs\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower rating\u003c\/strong\u003e: ≤ 62.5 VA \/ 32 W (safe area), ≤ 16 VA \/ 32 W (Zone 2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: With FDT\/DTM software, Requires configuration adapter 8978580000 CBX200 USB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat dissipation\u003c\/strong\u003e: ≤1,7 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating altitude\u003c\/strong\u003e: ≤ 2000 m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection degree\u003c\/strong\u003e: IP20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply voltage\u003c\/strong\u003e: 19.2\t31.2 V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of connection\u003c\/strong\u003e: Screw connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC standards\u003c\/strong\u003e: EN 61326-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e: 2.6 kV (input \/ output)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePollution severity\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated voltage\u003c\/strong\u003e: 300 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: EN 61010-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX - dust labelling\u003c\/strong\u003e: II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX - gas labelling\u003c\/strong\u003e: II (1) G [Ex ia Ga] IIC\/IIB\/IIA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIECEx - gas labelling\u003c\/strong\u003e: Ex ec nC IIC T4 Gc, [Ex ia Ga] IIC\/IIB\/IIA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation location\u003c\/strong\u003e: Device installed in safe area, zone 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTightening torque, min.\u003c\/strong\u003e: 0.4 Nm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTightening torque, max.\u003c\/strong\u003e: 0.6 Nm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClamping range, rated connection\u003c\/strong\u003e: 2.5 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClamping range, min.\u003c\/strong\u003e: 0.25 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClamping range, max.\u003c\/strong\u003e: 2.5 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire connection cross section AWG, min.\u003c\/strong\u003e: AWG 26\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire connection cross section AWG, max.\u003c\/strong\u003e: AWG 12\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Weidmüller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: ACT20X-HUI-SAO-S\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN\u003c\/strong\u003e: 8965490000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Signal Conditioner\/Transmitter\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.00 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":51150719549746,"sku":"8965490000","price":490.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305963272.jpg?v=1778616883","url":"https:\/\/voomisupply.com\/products\/weidmuller-8965490000-act20x-hui-sao-s","provider":"Voomi Supply","version":"1.0","type":"link"}