{"product_id":"weidmuller-8965350000-act20x-hdi-sdo-rnc-s","title":"Weidmuller 8965350000 ACT20X-HDI-SDO-RNC-S","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Weidmuller 8965350000 ACT20X-HDI-SDO-RNC-S is an EX signal isolating converter with one channel. It is designed with an Ex-input for NAMUR sensors or switches and a safe-output relay with NC contact. This device transmits digital signals, galvanically isolated, from potentially explosive atmospheres to safer areas. The input circuits are intrinsically safe and can process NAMUR sensor signals.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEX signal isolating converter, 1-channel\u003c\/li\u003e\n  \u003cli\u003eEx-input: NAMUR sensor\/switch\u003c\/li\u003e\n  \u003cli\u003eSafe-output: relay, NC contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis converter is designed for recording NAMUR sensor signals and digital switching signals from Ex zone 0, enhancing system availability with integrated alarm contacts for malfunction alerts.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Weidmuller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 8965350000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersion\u003c\/strong\u003e: EX signal isolating converter, 1-channel, Ex-input: NAMUR sensor\/switch, Safe-output: relay, NC contact\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder No.\u003c\/strong\u003e: 8965350000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Status relay\n1 NC (voltage-free)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e: 4032248784868\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 113.6 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth (inches)\u003c\/strong\u003e: 4.472 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 119.2 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight (inches)\u003c\/strong\u003e: 4.693 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 22.5 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth (inches)\u003c\/strong\u003e: 0.886 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet weight\u003c\/strong\u003e: 175 g\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage temperature\u003c\/strong\u003e: -20 °C...85 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: -20 °C...60 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 0...95 % (no condensation)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSIL in compliance with IEC 61508\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMTBF\u003c\/strong\u003e: 207 a\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status\u003c\/strong\u003e: Compliant with exemption\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Exemption (if applicable\/known)\u003c\/strong\u003e: 7a, 7cI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH SVHC\u003c\/strong\u003e: Lead 7439-92-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCIP\u003c\/strong\u003e: 2f6dd957-421a-46db-a0c2-cf1609156924\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting position\u003c\/strong\u003e: horizontal or vertical\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting rail\u003c\/strong\u003e: TS 35\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of mounting\u003c\/strong\u003e: Snap mounting support rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput frequency\u003c\/strong\u003e: \u0026lt;20 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput resistance\u003c\/strong\u003e: 1 kΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNAMUR supply\u003c\/strong\u003e: 8 V DC \/ 8 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of inputs, Ex\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput signal in case of wire break\u003c\/strong\u003e: \u0026lt;0.1 mA\n\u0026gt; 6.5 mA (in case of wire break)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePulse duration\u003c\/strong\u003e: \u0026gt; 0.1 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResistance\u003c\/strong\u003e: RP = 750 Ω \/ RS = 15kΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor\u003c\/strong\u003e: NAMUR sensor, according to EN60947-5-6\nswitch with or without RS, RP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor supply\u003c\/strong\u003e: 8 V DC \/ 8 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrigger level high\u003c\/strong\u003e: \u0026gt; 2.1 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrigger level low\u003c\/strong\u003e: \u0026lt;1.2 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuous current\u003c\/strong\u003e: ≤ 0.5 A AC \/ 0.3 A DC (safe zone)\n≤ 0,5 A AC \/ 1 A DC (zone 2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e: Output = input\ndirect or inverse (configurable)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax. switching frequency\u003c\/strong\u003e: 20 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal switching voltage\u003c\/strong\u003e: ≤ 125 V AC \/ 110 V DC (safe area)\n≤ 32 V AC \/ 32 V DC (zone 2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of digital outputs\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSwitching capacity\u003c\/strong\u003e: 500 VA \/ 60 W (safe area)\n16 VA \/ 60 W  (zone 2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlarm function\u003c\/strong\u003e: Device error\nFailure of power supply\nShort circuit at input\nOpen circuit at input\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHysteresis\u003c\/strong\u003e: 0.1 mA (switching threshold)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of alarm outputs\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower rating\u003c\/strong\u003e: ≤ 62.5 VA \/ 32 W (safe area)\n≤ 16 VA \/ 32 W (Zone 2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: With FDT\/DTM software\nRequires configuration adapter 8978580000 CBX200 USB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat dissipation\u003c\/strong\u003e: ≤1,2 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating altitude\u003c\/strong\u003e: ≤ 2000 m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection degree\u003c\/strong\u003e: IP20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply voltage\u003c\/strong\u003e: 19.2…31.2 V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of connection\u003c\/strong\u003e: Screw connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC standards\u003c\/strong\u003e: EN 61326-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e: 2.6 kV (input \/ output)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated voltage\u003c\/strong\u003e: 300 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: EN 61010-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX - dust labelling\u003c\/strong\u003e: II (1) D [Ex ia Da] IIIC\nI (M1) [Ex ia Ma] I\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX - gas labelling\u003c\/strong\u003e: II (1) G [Ex ia Ga] IIC\/IIB\/IIA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIECEx - gas labelling\u003c\/strong\u003e: Ex ec nC IIC T4 Gc\n[Ex ia Ga] IIC\/IIB\/IIA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation location\u003c\/strong\u003e: Device installed in safe area, zone 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTightening torque, min.\u003c\/strong\u003e: 0.4 Nm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTightening torque, max.\u003c\/strong\u003e: 0.6 Nm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClamping range, rated connection\u003c\/strong\u003e: 2.5 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClamping range, min.\u003c\/strong\u003e: 0.25 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClamping range, max.\u003c\/strong\u003e: 2.5 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire connection cross section AWG, min.\u003c\/strong\u003e: AWG 26\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire connection cross section AWG, max.\u003c\/strong\u003e: AWG 12\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTime interval\u003c\/strong\u003e: 3 years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eETIM 8.0\u003c\/strong\u003e: EC002653\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eETIM 9.0\u003c\/strong\u003e: EC002653\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eETIM 10.0\u003c\/strong\u003e: EC002653\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eECLASS 14.0\u003c\/strong\u003e: 27-21-01-20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eECLASS 15.0\u003c\/strong\u003e: 27-21-01-20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComponent\u003c\/strong\u003e: EX Signal Isolating Converter\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Weidmuller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN\u003c\/strong\u003e: 8965350000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: Weidmuller 8965350000 ACT20X\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondition\u003c\/strong\u003e: New\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal Conditioner Input\u003c\/strong\u003e: Digital\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal Conditioner Output\u003c\/strong\u003e: Digital\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo. of Output Channels\u003c\/strong\u003e: 1Channels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy %\u003c\/strong\u003e: -\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Range\u003c\/strong\u003e: -\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":51150206632242,"sku":"8965350000","price":214.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305963479.jpg?v=1778607734","url":"https:\/\/voomisupply.com\/products\/weidmuller-8965350000-act20x-hdi-sdo-rnc-s","provider":"Voomi Supply","version":"1.0","type":"link"}