{"product_id":"weidmuller-1506220000-act20p-ci-2co-p-s","title":"Weidmuller 1506220000 Act20p-ci-2co-p-s","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Weidmuller 1506220000 ACT20P-CI-2CO isolates analogue standard current signals from a power source or from a 2- or 3-wire sensor. An analogue input current signal is converted linearly and doubled to provide two galvanically isolated output current signals. The power supply is galvanically isolated from the input and output (4-way isolation).\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHART-compatible for 0.5 - 2.5 kHz\u003c\/li\u003e\n  \u003cli\u003eThe active or passive mA signal inputs are fully galvanically isolated.\u003c\/li\u003e\n  \u003cli\u003eOperating status display on a front panel LED\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis analog isolating amplifier doubles an analog input current signal to provide two galvanically isolated output current signals. It features 4-way isolation between input, output and supply.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Weidmuller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 1506220000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: CN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersion\u003c\/strong\u003e: Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 2 x 0(4) - 20 mA, Voltage supply also via CH20M rail bus, HART\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder No.\u003c\/strong\u003e: 1506220000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: active\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e: 4050118314724\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 113.7 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth (inches)\u003c\/strong\u003e: 4.476 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 127.1 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight (inches)\u003c\/strong\u003e: 5.004 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 12.5 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth (inches)\u003c\/strong\u003e: 0.492 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage temperature\u003c\/strong\u003e: -40 °C...85 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: -20 °C...60 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity at operating temperature\u003c\/strong\u003e: 0...95 % (no condensation)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5...95 %, no condensation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSIL in compliance with IEC 61508\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status\u003c\/strong\u003e: Compliant with exemption\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Exemption (if applicable\/known)\u003c\/strong\u003e: 7a, 7cI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH SVHC\u003c\/strong\u003e: Lead 7439-92-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCIP\u003c\/strong\u003e: 2f6dd957-421a-46db-a0c2-cf1609156924\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput current\u003c\/strong\u003e: 0...20 mA\n4…20mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput signal\u003c\/strong\u003e: HART signal\nbidirectional\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber inputs\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor\u003c\/strong\u003e: 2-wire transmitter (without own power supply)\n3-wire sensor\n4- wire sensor (with own power supply)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor supply\u003c\/strong\u003e: \u0026gt; 17 V DC at 20 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage drop\u003c\/strong\u003e: ca. 3.8 V @ R\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad\u003c\/strong\u003e: = 600 Ω; (I\ninput\n= 20 mA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad impedance current\u003c\/strong\u003e: \u0026lt;300 Ω\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of outputs\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput current\u003c\/strong\u003e: 0…20 mA (if input: 0…20 mA)\n4…20 mA (if input: 4…20 mA)\nHART\ndigital signal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: \u0026lt;0.1 % of end value\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: none\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent consumption\u003c\/strong\u003e: ≤60 mA (24V power supply, 20mA output)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting rail\u003c\/strong\u003e: TS 35\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal power consumption\u003c\/strong\u003e: 2 VA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating altitude\u003c\/strong\u003e: ≤ 2000 m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection degree\u003c\/strong\u003e: IP20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStep response time\u003c\/strong\u003e: ≤ 0,5 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply voltage\u003c\/strong\u003e: 20…30 V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature coefficient\u003c\/strong\u003e: 80 ppm\/K\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of signal forwarding according to HART\u003c\/strong\u003e: unchanged\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC standards\u003c\/strong\u003e: EN 61326-1\nEN 61000-6-2\nEN 61000-6-4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGalvanic isolation\u003c\/strong\u003e: 3-way isolator\nbetween input ⁄ output ⁄ supply\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eImpulse withstand voltage\u003c\/strong\u003e: 4 kV (1.2\/50 µs)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e: 2 kV inputs \/ outputs \/ power supply\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation voltage input or output\/supply\u003c\/strong\u003e: 2 kV inputs \/ outputs \/ power supply\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePollution severity\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSurge voltage category\u003c\/strong\u003e: III\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTest voltage\u003c\/strong\u003e: 0.3 kV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIECEx - gas labelling\u003c\/strong\u003e: Ex ec IIC T5 Gc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarking\u003c\/strong\u003e: II 3 G  Ex ec IIC T5 Gc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of connection\u003c\/strong\u003e: Screw connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTightening torque, min.\u003c\/strong\u003e: 0.4 Nm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTightening torque, max.\u003c\/strong\u003e: 0.6 Nm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClamping range, rated connection\u003c\/strong\u003e: 2.5 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClamping range, min.\u003c\/strong\u003e: 0.5 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClamping range, max.\u003c\/strong\u003e: 2.5 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire connection cross section AWG, min.\u003c\/strong\u003e: AWG 26\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire connection cross section AWG, max.\u003c\/strong\u003e: AWG 12\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated supply voltage DC (V)\u003c\/strong\u003e: 24 - 24\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of input ranges 0 mA ... 20 mA\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of input ranges 4 mA ... 20 mA\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of output ranges 0 mA ... 20 mA\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of output ranges 4 mA ... 20 mA\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower consumption (W)\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature drift (%\/K)\u003c\/strong\u003e: 0.02\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConstruction type of device\u003c\/strong\u003e: Field device\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDegree of protection (IP)\u003c\/strong\u003e: IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":50997068792114,"sku":"1506220000","price":270.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/297721482.jpg?v=1774030290","url":"https:\/\/voomisupply.com\/products\/weidmuller-1506220000-act20p-ci-2co-p-s","provider":"Voomi Supply","version":"1.0","type":"link"}